The intelligent transformer calibrator is used for error, impedance, and admittance testing of PT and CT. Meet the requirements of the national JJG313-94 "Verification Regulations for Measuring Current Transformers" and JJG314-94 "Verification Regulations for Measuring Voltage Transformers".
Product Name: Transformer Calibration Instrument, Transformer Current Calibration Instrument, Fully Automatic Transformer Calibration Instrument, Fully Automatic Current Transformer Calibration Instrument, Fully Automatic Voltage Transformer Tester, Transformer Field Calibration Instrument, Current Transformer Field Calibration Instrument, Voltage Transformer Field Calibration Instrument
| Equipment usage environment | Temperature: 5 ℃~40 ℃ | Relative humidity:<80% (at 25 ℃) |
| Altitude:< 2500m | ||
| Power frequency: 50Hz ± 0.5Hz | Power supply voltage: 220V ± 5V | |
| measuring range | In-phase component (%): 0.0001-200.0 | Resolution: 0.0001 |
| Orthogonal components (fractions): 0.001-700.0 | Resolution: 0.001 | |
| Impedance (Ω): 0.0001-20.0 | Resolution: 0.0001 | |
| Admittance (ms): 0.0001-20.0 | Resolution: 0.0001 | |
| Basic error | in-phase | Δ X=± (X × 2%+Y × 2%) ± Dx (with 1 level optional) |
| Quadrature Component | Δ Y=± (X × 2%+Y × 2%) ± Dy (with 1 level optional) | |
| X "," Y "- instrument display values | ||
| Dx, Dy "- Quantification Error of Instruments | ||
| Dx=2,Dy=5 | ||
| dial indicator | Level 2 (with Level 1 optional) | |
| scope of work | electric current | (1%~149%)In (In =5A) |
| (5%~149%)In (In =1A) | ||
| voltage | (5%~149%)Un (Un =100V,150V,100V/) | |
| (5%~149%)Un (Un =100V/3) | ||
| Workload | electric current | To TX < 0.12 Ω cos Φ=1 |
| voltage | A for x<0.25VA (100V) | |
| Polarity error indication | When the working current (voltage) reaches more than 5% of the rated current (voltage) and the error exceeds 180%, there should be a polarity indication. | |
| Attention: If the polarity indication still does not appear after exceeding 10% of the rated working current (voltage), it indicates a fault. Please do not increase the current (voltage) again to avoid burning out the instrument. | ||
| Variable ratio error indication | When the working current (voltage) reaches more than 5% of the rated current (voltage) and the error exceeds 30% but is less than 180%, there should be a ratio error indication. | |
| Insulation and voltage withstand tests and instructions | Terminal TX() is connected to the terminal | |
| The power socket can withstand a voltage of 1.5kV and a 1-minute withstand voltage for the casing | ||
1. The appearance of the product is subject to the actual product. Technical parameters and models are subject to change without prior notice. If there is any act of theft or copying, legal responsibility will be pursued.
2. To learn more about Huatian products, please enter the product center. Service Hotline: 400-8855-448
Instrument host
appearance
panel
Host power switch
Wiring hole
RS232 interface
Keypad
interface
Instruction manual, inspection certificate, certificate of conformity
On site production drawing 1
On site production drawing 2
On site production drawing 3
On site production drawing 4
Our company's products are strictly produced in accordance with international and national standards and industry regulations. They have passed the testing of national, provincial, and municipal power research institutes, measurement centers, and authoritative power departments, and have fully passed the ISO9001 international quality management system certification, the People's Republic of China manufacturing measuring instrument license, GB/T19001-2016 quality management system requirements, GB/T24001-2016 environmental management system requirements, and GB/T45001-2020 occupational health and safety management system requirements.