HTBS-V Transformer No load Load Characteristics Tester

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Dedicated to testing reference standards for transformer no-load loss, short-circuit loss, zero sequence impedance, and short-circuit impedance: DL/T 1256-2013 Product Manual Verification Certificate Standards and Regulations Product Atlas Video shooting can measure the no-load current, no-load loss, impedance voltage, load loss, and zero sequence impedance of various types of transformers. Real time waveforms of each phase voltage and current can be displayed intuitively, and waveform distortion can be measured. Three phase voltage, three-phase current, average voltage, average current, two-phase active power, total power can be measured. Note: For product purchase, technical maintenance, and other services, please feel free to call!

Product Details

The transformer short-circuit impedance tester is a high-precision instrument developed and researched by our company specifically for measuring transformer no-load, load parameters, and zero sequence impedance parameters. It can accurately measure a series of parameters such as no-load current, no-load loss, short-circuit loss, impedance voltage, harmonic content, distortion rate, etc. of various transformers.

The transformer short-circuit impedance tester has the advantages of small size, light weight, high measurement accuracy, good stability, and easy operation and learning. It can replace the traditional method of measuring transformer loss and capacity using multiple meters, with simple wiring, easy testing and recording, greatly improving work efficiency. It uses a large screen image form of true color LCD as the display window, with graphical menu operation and Chinese character prompts. It integrates multiple parameters into one screen display interface, with a friendly human-machine dialogue interface, easy and fast to use, and is the preferred product for power users at all levels.

Product nickname: Transformer no-load tester, Transformer no-load and load characteristic tester, Transformer loss tester, Transformer no-load load tester, Transformer no-load tester, Transformer characteristic tester

Product parameters

technical parameters

Input characteristics Voltage measurement range Width limit from 0 to 750V
Current measurement range 0~5~100A internal automatic range switching
accuracy voltage ±0.2%
current ± 0.2% range
power ±0.5%(CosΦ>0.1),±1.0%(0.05< CosΦ<0.1)
Operating Temperature -10℃~+40℃
working power supply Communication between 160V and 265V
insulation The insulation resistance between the voltage and current input terminals and the casing is ≥ 100M Ω
The input end of the working power supply is subjected to a power frequency of 2kV (effective value) between the casing, and the experiment lasts for 1 minute
volume 32×24×13cm3
weight 3kg
Note:

1. The appearance of the product is subject to the actual product. Technical parameters and models are subject to change without prior notice. If there is any act of theft or copying, legal responsibility will be pursued.

2. For more information on ultra-high voltage products, please enter the product center. Service Hotline:

Product features
  • 1. Can measure the no-load current, no-load loss, impedance voltage, load loss, and zero sequence impedance of various types of transformers

  • 2. It can automatically perform waveform distortion correction, temperature correction (providing two methods of simple temperature correction and additional loss correction), voltage correction (no-load test under non rated voltage), and current correction (short-circuit test under non rated current conditions), which is very suitable for units that do not have slightly larger capacity transformer short-circuit test conditions

  • 3. It can measure three-phase voltage, three-phase current, average voltage, average current, two-phase active power (due to the use of a two power meter method, only the power of phases A and C is displayed here), and total power

  • 4. It can measure the content of 2-42nd harmonic of each phase voltage and current, as well as the total distortion rate (harmonic distortion) of each signal

  • 5. It can display real-time waveforms of voltage and current in each phase, intuitively showing the distortion of the waveform

  • 6. Voltage circuit width limit: The voltage can be measured up to 750V without switching gears to ensure accuracy. Will not cause damage to the instrument itself due to incorrect voltage gear selection

  • 7. The large screen, full Chinese character menu, and operation prompts enable friendly human-machine dialogue. The conductive rubber buttons make operation easier, and the high brightness true color LCD display can adapt to all seasons of winter and summer

  • 8. Users can print out the results of the test data at any time through a micro printer

  • 9. All test results can be recorded and saved for future reference

  • 10. Built in real clock, can display the current date and time in real time, and can also store the test time when storing records