AS-60PlusHJ1261-2022 Benzene series automatic sampler
Fast and stable new generationHJ1261-2022 Benzene series automatic sampler
Purpose:Mainly used inVOCTheSVOCInject various gas samples such as non methane total hydrocarbons, gas bags, syringes, and soda tanks.
Applicable standards:J1261—2022Fixed pollution source exhaust gas Determination of benzene derivatives-Air bag sampling - direct injection - gas chromatography methodTheHJ38-2017Determination of fixed pollution source exhaust gas, total hydrocarbons, methane, and non methane total hydrocarbons-Gas chromatographyHJ 1006-2018 Determination of volatile halogenated hydrocarbons in fixed source exhaust gases Gas bag sampling Gas chromatography methodWait.
Features:
lMFC electronic mass flowmeter: precise control of sample flow rate, ensuring accuracy of standard and sample flow rates.
lFully Inert Pipeline System:No adsorption or residue, ensuring precise linearity and repeatability
lAutomatic standard curve: One click dilution of standard curve, fast and accurate.
lAutomatic sample dilution injection:One click dilution of high concentration samples.
lFully automatic sequential injection:Fast and stable.
lInjection method:standard configuration1mlQuantitative ring(0.5mlThe1mlThe2ml(Optional)
lSecondary sample dilution function: For high concentration samples, multiple gradient dilutions can be performed, and the dilution factor can easily exceed 10000 times. Sample injection number:16、32、48、64bit
lHeating function of transmission line, valve and quantitative ring: ensuring the sample transmission processChineseThere are no cold spots throughout the entire process.
lCeramic sample valve: no adsorption, no residue
lAutomatic sample pipeline cleaning function: After injection is completed, the sample pipeline can be automatically cleaned.
lBackblowing and pre blowing function: Before injection, nitrogen can be used to back blow the injection pipeline and pre rinse the sample pipeline with the sample.
lSample balancing function: Ensure pressure balance between the sample and the ambient atmosphere during the injection process to ensure injection accuracy.
Application case:
Test conditions:AS-60PlusconnectAgilent7890A,FIDDetector and chromatographic column:DB-WAX 30Mx0.32mmX0.50um
Reference standard method
J1261—2022Fixed pollution source exhaust gas Determination of benzene derivatives
Curve range:0.1ppm--10ppm
Both standard curves and linearity can be achieved999The above.