- Phone
-
Address
Building 6, Optics Valley Electromechanical Industrial Park, No. 84 Gaoxin 5th Road, Donghu New Technology Development Zone, Wuhan City, Hubei Province
Wuhan Ultra High Voltage Power Technology Co., Ltd
Building 6, Optics Valley Electromechanical Industrial Park, No. 84 Gaoxin 5th Road, Donghu New Technology Development Zone, Wuhan City, Hubei Province
HEY-H Intelligent Transformer Calibration InstrumentUsed for error, impedance, and admittance testing of PT and CT. Meet the requirements of the national JJG313-94 "Verification Regulations for Measuring Current Transformers" and JJG314-94 "Verification Regulations for Measuring Voltage Transformers".
Product Name: Transformer Calibration Instrument, Transformer Current Calibration Instrument, Fully Automatic Transformer Calibration Instrument, Fully Automatic Current Transformer Calibration Instrument, Fully Automatic Voltage Transformer Tester, Transformer Field Calibration Instrument, Current Transformer Field Calibration Instrument, Voltage Transformer Field Calibration Instrument
| Equipment usage environment | Temperature: 5 ℃~40 ℃ | Relative humidity:<80% (at 25 ℃) |
| Altitude:<2500m | ||
| Power frequency: 50Hz ± 0.5Hz | Power supply voltage: 220V ± 5V | |
| measurement range | In-phase component (%): 0.0001-200.0 | Resolution: 0.0001 |
| Orthogonal components (fractions): 0.001-700.0 | Resolution: 0.001 | |
| Impedance (Ω): 0.0001-20.0 | Resolution: 0.0001 | |
| Admittance (ms): 0.0001-20.0 | Resolution: 0.0001 | |
| basic error | in-phase component | Δ X=± (X × 2%+Y × 2%) ± Dx (with 1 level optional) |
| orthogonal component | Δ Y=± (X × 2%+Y × 2%) ± Dy (with 1 level optional) | |
| 'X', 'Y' - instrument display values | ||
| 'Dx, Dy' - Quantification Error of Instruments | ||
| Dx=2,Dy=5 | ||
| dial indicator | Level 2 (with Level 1 optional) | |
| scope of work | current | (1%~149%)In (In =5A) |
| (5%~149%)In (In =1A) | ||
| voltage | (5%~149%)Un (Un =100V,150V,100V/) | |
| (5%~149%)Un (Un =100V/3) | ||
| workload | current | To TX < 0.12 Ω cos Φ=1 |
| voltage | A for x<0.25VA (100V) | |
| Polarity error indication | When the working current (voltage) reaches more than 5% of the rated current (voltage) and the error exceeds 180%, there should be a polarity indication | |
| Attention: If the polarity indication still does not appear after exceeding 10% of the rated working current (voltage), it indicates a fault. Please do not increase the current (voltage) again to avoid burning out the instrument | ||
| Variable ratio error indication | When the working current (voltage) reaches more than 5% of the rated current (voltage) and the error exceeds 30% but is less than 180%, there should be a ratio error indication | |
| Insulation and voltage withstand tests and instructions | Terminal TX is connected to the terminal | |
| The power socket can withstand a voltage of 1.5kV and a 1-minute withstand voltage for the casing | ||
1. The appearance of the product is subject to the actual product. Technical parameters and models are subject to change without prior notice. If there is any act of theft or copying, legal responsibility will be pursued.
2. For more information on ultra-high voltage products, please enter the product center.
1HEY-H Intelligent Transformer Calibration InstrumentAdopting 320 × 240 dot matrix LCD, with a wide visual range and long-lasting backlight illumination, convenient to use
2. Full Chinese operation interface, beautiful interface
3. The dial gauge, ratio difference, and angle difference are displayed in large font for easy observation by users
4. The intelligent transformer calibrator produced by our company meets the requirements of JJG314-1993 and JJG314-1994, with automatic sampling
5. Automatic polarity judgment error, variable ratio error
6. The upper computer software has virtual instrument open function
7. Resolve S-level measurement issues
8. Automatic range switching
9. By combining * circuit and DSP technology, the problem of unstable resistance capacitance phase-shifting circuit can be resolved
10. Power consumption:<15VA (without micro printer); <25VA (with micro printer)
11. Harmonic suppression ratio:>40dB
12. Dimensions (length x width x height): 260 x 350 x 150mm3
13. Large screen 320 × 240 dot matrix LCD with long-lasting backlight illumination
14. Automatically determine polarity errors, variable ratio errors, and have virtual instrument open function
15. Weight: 6kg




