As a global manufacturer of Taiwanese gas chromatography, the United StatesPEThe company'sCluras 580 GCA chromatograph is a gas chromatography analysis instrument. Shenzhen Huachang Haitai Technology Co., Ltd. imports from the United StatesPEMainstream products of the companyCluras 580 GCAs a platform, we have integrated our company's transformer oil gas chromatography separation technology and specialized chromatography analysis and fault diagnosis software to create a high-performance transformer oil gas chromatography analysis dedicated system for power system users.
Instrument features:
1、 The world's first fully Chinese interactive color graphical touch screen control touch screen interface
Clarus 580 GCMultiple languagesTouch screen and graphical user interfaceMake the development, editing, and calling of instrument methods simple and smooth, and make instrument control exceptionally simple. Main advantages:
Using the local language can quickly learn how to operate and improve instrument utilization
◆ Full Chinese color graphical interface, making it very intuitive and vivid to use
Innovative design makes the establishment and invocation of analytical methods simple and smooth
The status screen displays all the status of the instrument system, allowing you to quickly browse through it
◆ Graphic design enables you to quickly and easily identify the selected injection port and other devices, and timely judge the real-time status
The touch screen control software also comes with built-in practical tools that can help view column installation parameters, calculate column flow rate, etc
◆ Real time chromatogram display allows you to continuously monitor the progress of analysis.
IIA high-performance program controlled pneumatic system(PPC)
It is possible to directly set the injection port pressure, flow rate, linear velocity, and split ratio separately.
ThroughClaurs 580 GCThe touch screen allows for easy setting of pressure and flow rates for all air circuits
PPCThe system can automatically monitor all pneumatic systems. When the pneumatic parameters deviate from the set values,PPCIt will automatically sound an alarm
Capable of automatically adjusting the carrier gas flow rate to compensate for changes in carrier gas flow rate caused by external temperature or pressure fluctuations, ensuring the reproducibility of analysis results
Can provide electronic pressure programming, flow programming, and linear velocity programming for carrier gas
The constant linear velocity operation mode ensures that when the chromatographic column parameters change, it does not affect the peak retention time and can achieve retention time reproduction (locking) on different instruments
3、 Instrument performance parameters
1.column oven
★ Temperature control range of column temperature box:Above room temperature5°C450°C
2.injection port
★ Filling column injection port suitable for transformer oil and gas analysis(PAK)
Temperature range for use:50~450℃
support1/4perhaps1/8Stainless steel or glass filled columns
Can be equipped with a full program pneumatic control system(PPC)The control parameters include: pressure(0-100.0psi/min), traffic(0-100.0mL/min)
3.detector
★ Hydrogen flame ionization detector(FID)
Working temperature:100~450℃
Low detection limit:<3×10-12gC/secNonane, signal-to-noise ratio:2:1
Linear range:>107
Equipped with automatic ignition function
★Thermal conductivity detector(TCD)
Operating temperature:100~400℃, incremental1℃
Sensitivity: Temperature measurement on the bridge100℃, bridge current160mAWhen is9microvolt/ppmnonane
Minor inspection measurement: <1ppmnonane
Linear range: >105
Equipped with gas cut-off protection function
4. Detection performance of dissolved gases in transformer oil
Sensitivity meetsGB/T7252-2001New national standard requirements.
H2≤ 2μL/L,
CO、CO2≤25μL/L,
C2H2≤ 0.1μL/L
Stable startup time: less than40minute
4、 Advanced specialized analysis process
Suitable for transformer oil and gas analysisHC-TOGAP-1Single column analysis process;
Developed by Shenzhen Huachang Haitai Technology Co., LtdHC-TOGAP-1The single column analysis process can be used in8Completely separate transformer oil within minutes8Dissolved gas components:H2、O2、CO、CO2、CH4、C2H4、C2H6、C2H2Excellent separation performance, meeting the requirementsGB/T 7252-2001requirement.
5、 Specialized analysis software
HCW-3000The analysis software is developed by Shenzhen Huachang Haitai Technology Co., Ltd. specifically for transformer oil analysis in power systems, and has the following characteristics:
Chinese interface, easy to operate;
According to the operating habits of power system users,HCW-3000Specially designed for user convenience and speed in various operational aspects, the program modules are interconnected and can be flexibly switched or called upon, achieving almost seamless operation;
The database management system covers comprehensive data management of user operations, including sample condition information, data information, spectrum information, equipment information, simplified experimental information, etc. Users can perform necessary operations on the data, such as querying, reporting, printing, reprocessing, etc;
The fault diagnosis system covers the determination of fault nature (three ratioTDDiagram, expert system, and analysis of fault change trends.
ordering guide:
|
HCGC-580ABasic type:580GCHost(FID、TCDDetector, manual flow control), workstation software, computer, printer |
|
HCGC-580BStandard type:580GCHost(FID、TCDDetector,PPCElectronic flow control, workstation software, computer, printer |
|
HCGC-580AHcomposite:580GCHost(FID、TCDDetector, manual flow control), workstation software, computer, printer. Transformer oil analysis+gas content analysis HCGC-580BHcomposite:580GCHost(FID、TCDDetector,PPCElectronic flow regulation, workstation software, computer, printer. Transformer oil analysis+gas content analysis |
|
Optional parts (accessory equipment): oscillator, mixed standard gas, hydrogen/air generator, nitrogen cylinder, pressure gauge, accessories, etc |