E-mail
szhcht@163.com
-
Phone
18818683927
-
Address
Room 556, Jinda Technology Center, No. 8 Kefeng Road, Nanshan District, Shenzhen
Shenzhen Huachang Haitai Technology Co., Ltd
szhcht@163.com
18818683927
Room 556, Jinda Technology Center, No. 8 Kefeng Road, Nanshan District, Shenzhen
HCGC-280It is an economical and applicable gas chromatography analysis system for dissolved gases in transformer oil launched by Shenzhen Huachang Haitai Technology Co., Ltd. The system uses a domestically produced host (three detectors) and a dedicated analysis process to completely separate the insulating oil in one injection7Dissolved gas components (includingH2、CO、CO2、CH4、C2H4、C2H6、C2H2), can meetThe need for chromatographic analysis of dissolved gases in transformer oil in the power system.
Technical features:
l Large screen LCD display
l Chinese Menu
l key operation
l digitizeFIDElectronic zeroing technology enhances the anti-interference ability of instruments
Using electronic zeroing technology to achieveFIDElectronic regulation of output signal level. Due to the fact that electronic adjustment can be directly installed on the signal channel of the circuit board, the electronic noise suppression capability is improved, and there is no interference signal when connecting mechanical potentiometers. Due to the reduction of parasitic parameters, it has strong anti-interference ability.
l Thermal conductivity tungsten wire gas cutoff protection function
HCGC-280Equipped with intelligent thermal conductivity cut-off protection function, when the carrier gas pressure is below the safety threshold, the system will automatically cut off the thermal conductivity current to protect the thermal conductivity detector from damage.
Technical parameters:
1 Small detection concentration (unit)µL/L):
|
H2 |
CO |
CO2 |
CH4 |
C2H4 |
C2H6 |
C2H2 |
|
2 |
2 |
2 |
0.1 |
0.1 |
0.1 |
0.1 |
2 Qualitative repeatability: deviation≤1%
3 Quantitative repeatability: deviation≤3%
4 Execution standards:
5 GB/T 17623-1998Gas chromatography method for determining the content of dissolved gas components in insulating oil
GB/T 7252-2001Guidelines for Analysis and Determination of Dissolved Gases in Transformer Oil
6 Technical specifications of detector:
|
Thermal conductivity detector(TCD) |
Hydrogen flame ionization detector(FID) |
|
Adopting a semi diffusive structure |
Cylindrical collection electrode structure design, quartz nozzle, extremely responsive |
|
The power supply adopts constant current control mode |
Automatic ignition; Stable time: Ten minutes |
|
Sensitivity: ≥2500mV·ml/mg(Hexadecane)/Isooctane) |
Detection limit: ≤8×10-12g/s(Hexadecane)/Isooctane) |
|
Baseline noise: ≤20μV |
Baseline noise: ≤2×10-13A |
|
Baseline drift: ≤100μV/30min |
Baseline drift: ≤2×10-12A/30min |
|
Line Sex: ≥104 |
Linear: ≥106 |
7 Temperature control range: above room temperature8℃~399℃ Accuracy ±0.1℃