HCGC-180It is a portable specialized chromatograph newly launched by Shenzhen Huachang Haitai Technology Co., Ltd. for rapid on-site analysis. The instrument adopts the classic three detector process and can complete the dissolution of insulating oil in one injection7Full analysis of gas component content (includingH2、CO、CO2、CH4、C2H4、C2H6、C2H2)The analysis data is completely consistent with traditional laboratory chromatography data.The instrument adopts advanced technologySmall modular designThe design concept is small in size and light in weight, making it easy to carry to the site for analysis. It is the best choice for large transformers that require on-site tracking and testing in case of abnormalities.
■ Features:
★Using computer reverse control technology to achieve instrument gas path pressure(Carrier gas, hydrogen gas, air) passing through the workstationDigital display
★Using computer reverse control technology to achieve instrument temperature(Including column boxes, detectors, converters, etcSettings, display, and other operations
★ Using computer reverse control technology,Click the mouse through the workstationRealize one click startup
★digitizeFIDElectronic zeroing technology enhances the anti-interference ability of instruments
Using electronic zeroing technology to achieveFIDElectronic regulation of output signal level. Due to the fact that electronic adjustment can be directly installed on the signal channel of the circuit board, the electronic noise suppression capability is improved, and there is no interference signal when connecting mechanical potentiometers. Due to the reduction of parasitic parameters, it has strong anti-interference ability.
★Using computer inverse control technology to achieve control of the oscillator
HCGC-180Provide power to a small oscillator through a connecting signal line, and operate the entire process of the oscillator, including temperature rise, starting oscillation, stopping, and beeping at the end, through a workstation
★Built in silent air pump, no need for external air source
HCGC-180The host comes with an imported small air pump that can provide uninterrupted air supply for the instrument. Due to its shockproof design, the air pump can work silently, and users will hardly feel its presence.
★ Thermal conductivity tungsten wire gas cutoff protection function
HCGC-180Equipped with intelligent thermal conductivity cut-off protection function, when the carrier gas pressure is below the safety threshold, the system will automatically cut off the thermal conductivity current to protect the thermal conductivity detector from damage.
■ Technical parameters:
1 Detection range (unit)µL/L):
|
component |
H2 |
CO |
CO2 |
CH4 |
C2H4 |
C2H6 |
C2H2 |
|
detection range |
2-10000 |
2-50000 |
2-50000 |
0.1-2000 |
0.1-2000 |
0.1-2000 |
0.1-2000 |
2 Qualitative repeatability: deviation≤1%
3 Quantitative repeatability: deviation≤3%
4 Technical specifications of detector:
|
Thermal conductivity detector(TCD) |
Hydrogen flame ionization detector(FID) |
|
Adopting a semi diffusive structure |
Cylindrical collection electrode structure design, quartz nozzle, extremely responsive |
|
The power supply adopts constant current control mode |
Automatic ignition; Stable time: Ten minutes |
|
Sensitivity: ≥2500mV·ml/mg(Hexadecane)/Isooctane) |
Detection limit: ≤8×10-12g/s(Hexadecane)/Isooctane) |
|
Baseline noise: ≤20μV |
Baseline noise: ≤2×10-13A |
|
Baseline drift: ≤100μV/30min |
Baseline drift: ≤2×10-12A/30min |
|
line Sex: ≥104 |
Linear: ≥106 |
5 Temperature control range: above room temperature8℃~399℃ Accuracy ±0.1℃
6 External dimensions:380*450*180mm
7 Weight:<15kg
■ Execution standards
★ GB/T 17623-1998Gas chromatography method for determining the content of dissolved gas components in insulating oil
★ GB/T 7252-2001Guidelines for Analysis and Determination of Dissolved Gases in Transformer Oil
★ DL/T 703-1999Determination of Gas Content in Insulating Oil by Gas Chromatography
■ Configuration
|
product name |
Specification, model and description |
quantity |
|
Portable chromatograph for transformer oil |
HCGC-180 |
1tower |
|
Transformer oil dedicated chromatography workstation |
1cover |
|
|
Small fully automatic oscillator |
SZD-5Type, open the door up,2Support installation.
Oscillation frequency:275±5order/Divide, vibrate Width:36mm
electricity Source:AC220V 50Hz weight Quantity:8Kg |
1tower |
|
standard gas |
1LAluminum alloy bottle,7Components |
1bottle |
|
High purity nitrogen gas in small bottles |
2LAluminum alloy bottle |
2bottle |
|
High purity hydrogen gas in small bottles |
2LAluminum alloy bottle |
2bottle |
|
Notebook computer |
|
1tower |