Welcome Customer !

Membership

Help

Beijing United Shengchao Technology and Trade Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

HARTIP1500 hardness tester

NegotiableUpdate on 09/30
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Product detailed introduction Detailed parameters HARTIP1500 hardness tester adopts DC probe design, small volume, especially suitable for hardness measurement inside the cavity

Product Details

  • Product Details
  • Detailed specifications

The HARTIP1500 hardness tester adopts a DC probe design, with a small volume, especially suitable for hardness measurement inside the mold cavity. According to user needs, conversion materials and hardness units can be added, such as the conversion values for alloy steel, stainless steel, cast iron and other materials when using DL type impact devices. This hardness tester has only two buttons and is extremely easy to operate. Hardness units such as Brinell, Rockwell, and Vickers can be automatically converted, and the price is very cheap. It is suitable for users with less functional requirements and has been loved by a large number of users since its launch.

Unique features of the product:

  • High precision ± 0.5% (HL=800), repeatability ± 4HL
  • Dual coil technology; Accurate and stable measurement values
  • Integrated design, convenient to carry and operate with one hand
  • Various hardness units can be converted to each other
  • Automatic power on/off
  • Using DC probe, shorter than ordinary probe, suitable for hardness measurement inside the mold cavity
  • Automatically calculate the average value
  • cheap

model

Hartip 1900

Hartip 1800

HARTIP1800B

Hartip 1500

style

Product Features

From all angles GType impact device, suitable forMeasurement of heavy and rough surface castings and forgings

From all angles D/DLInterchangeable impact body, pen style design for easy portability, roll hardness tester

From all angles D/DLInterchangeable impact body and pen style design for easy portability

Integrated design, compact size, economical and practical

precision

±4HLG

±0.3%@HL=800/±2HL

±0.5%@HL=800/±4HL

display

OLEDSuper bright display

12864Graphic dot matrix ultra large and bright display

Backlit LCD display

hardness value

HLG300-750/HRB47-100/HB90-650

HL/HRC/HRB/HB/HV/HS/σ B(rm

HL/HRC/HRB/HB/HV/HS

Impact device

Gtype

DType (Built in) D-DL2-in-1 type (optional)

DType (Built in)

Impact direction

Full angle

Full angle

360°

Applicable Materials

Steel, cast steel/Grey cast iron/ductile iron

Steel and cast steel/Alloy tool steel/stainless steel/gray cast iron/ductile iron/cast aluminum alloy/copper zinc alloy (brass)/copper tin alloy (bronze)/pure copper/forged steel/rolling mill

Steel and cast steel/Alloy tool steel/stainless steel/gray cast iron/ductile iron/cast aluminum alloy/copper zinc alloy (brass)/copper tin alloy (bronze)/pure copper/forged steel

Steel and cast steel/Alloy tool steel/stainless steel/gray cast iron/ductile iron/cast aluminum alloy/copper zinc alloy (brass)/copper tin alloy (bronze)/pure copper

storage capacity

400 storage groups, 36000A data

4 groups of 4000A data

99 data sets

statistics

Mean value, maximum value, minimum value, root mean square value

Mean value, maximum value, minimum value

calibration

Self calibrating for use

prompt

Low voltage prompt

communication

USB interface, Bluetooth wireless connection to computer

-

-

print

Bluetooth printer

-

power supply

3.7V lithium-ion rechargeable battery

9V alkaline battery

Operating Temperature

-40~+75℃

-40~+60℃

-10~+45℃

Instrument volume

250×47×37mm

148×44×22mm

116×60×33mm

Net weight

250g

110g

150g

standard

Complies with GB/T 17394-1998, ASTM A956 standard

Technical Specifications
model
Hartip 1500
Measurable materials
Steel, cast steel, alloy tool steel, stainless steel, cast iron, cast aluminum alloy, bronze, brass, pure copper
display
LCD (Liquid Crystal Display)
precision
± 0.5% (when HL=800)
measurement range
HL200-960/HRC19-70/HRB13-109/HB20-655
Hardness conversion
HL-HRC-HRB-HB-HV-HSD
temperature
-10 ℃ to+45 ℃
power supply
rechargeable battery
Overall Dimensions
100×60×33mm
weight
150g
Standard Configuration
HARTIP1500 Host
D-type impact device
D-type standard test block
rechargeable battery
Carrying case
brush
Instruction Manual
Optional Accessories
Irregular support ring (used for convex, concave, arc-shaped inner and outer walls, etc.)

Impact device D HLD:170-960

Experimental materials/Hardness system

HRC

HRB

HB

HV

HS

STEEL/CAST STEEL
Steel and cast steel

20.0-67.9

59.6-99.5

80-647

80-940

32.5-99.5

ALLOY TOOL STEEL
Alloy tool steel

20.5-67.1

80-898

STAINLESS STEEL
stainless steel

19.6-62.4

46.5-101.7

85-655

85-802

LAMELLAR IRON
gray cast iron

93-334

NODULAR IRON
ductile cast iron

131-387

CAST ALUMINUM
cast aluminum

30-159

BRASSCopper zinc alloy (brass)

13.5-95.3

40-173

BRONZE
Copper tin alloy (bronze)

60-290

WEOUGHT COPPER
pure copper

45-315