Guodian Nanrui NSR681RF-D Unit Measurement and Control Device

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The NSR681RF-D unit measurement and control device of Guodian Nanrui realizes functions such as single circuit breaker measurement and control, gear remote adjustment, temperature measurement, DC measurement, etc., and has synchronous function.

Product Details

Guodian Nanrui NSR681RF-D Unit Measurement and Control Device

Function Configuration

The main functions of measurement and control include:148 Road remote signal input acquisition, device remote signal displacementSOErecord;212 Road remote control divisionCombined, including1 Remote adjustment of road gear;31 Close the circuit breaker at the same time as the road inspection;42 Direct current measurement;51 Group gear measurement;6IaTheIbTheIcTheUaTheUbTheUcTheUabTheUbcTheUcaThe3UoTheUxThePaThePbThePcThePTheQTheSTheCOSφTheFrwait19 An analog quantityTelemetry;7)EventSOE.

Simultaneous function

1. Guodian Nanrui NSR681RF-D Unit Measurement and Control Deviceachievable1The synchronous function of the circuit breaker for each line.

2. There are two options for checking without pressure and checking during the same period: when checking without pressure and checking during the same period, checking without pressure takes priority; When no pressure is detected and the same period is detected, it will be opened at the same time; The synchronous closing has the functions of frequency difference locking, angle difference locking, pressure difference locking, and frequency difference acceleration locking. Busbars and linesPhase angle differenceMeasure once every half power frequency cycle, while taking into account the frequency differencefFrequency difference accelerationdf dtAnd the switch action timeTdqCalculate the phase angle difference of the circuit breaker at the moment of closing, ensuring that the phase angle difference of the circuit breaker at the moment of closing meets the set valueMeThe calculation formula is as follows:国电南瑞 NSR681RF-D 单元测控装置

When the leading angle satisfies the formula, a closing pulse can be sent to meet the setting value requirements.

3. The simultaneous closing should be completed within the entire group reset time. If the closing is still unsuccessful after the entire group reset time, the closing command will be cancelled.