E-mail
szhaixu17@126.com
-
Phone
1359031897818922858157
-
Address
903, Block C, Trading Plaza, No. 5 South China City, Pinghu, Longgang District, Shenzhen
Shenzhen Haixu Instrument Co., Ltd
szhaixu17@126.com
1359031897818922858157
903, Block C, Trading Plaza, No. 5 South China City, Pinghu, Longgang District, Shenzhen
The functions of the KEW 6017F multifunctional measuring instrument are as follows:
1 KEW 6017FHaving automatic discharge function: automatically releasing the charge in the charged voltage after testing.
2. When there is voltage in the circuit, it can be switched to AC600V.
3. An impact resistant elastic material shell.
4. Backlight function: Suitable for operations in dark environments.
5. The shoulder strap is convenient for both hands to work with.
6 KEW 6017FThe design complies with the international safety specification IEC61010-1 CAT. III 600V.
Gongli 6017F Multi functional Tester | Parameter Table of Gongli KEW 6017F Multi functional Measuring Instrument:
This parameter table is provided byKyoritsu、Fluke、TESTO、DeltaTRAKDistrict General Agent—Shenzhen Haixu Instrument and Meter Co., Ltd. provides original and authentic products
|
insulation resistance meter
|
earth resistance meter
|
||||||
|
rated
testing voltage |
6017
|
125V
|
250V
|
500V
|
----
|
Grounding resistance
(Simple Test) (Precision testing) |
12Ω
120Ω 1200Ω |
|
6018
|
----
|
250V
|
500V
|
1000V
|
|||
|
Effective maximum scale value
|
20MΩ
|
50MΩ
|
100MΩ
|
200MΩ
|
|||
|
median
|
0.5MΩ
|
1MΩ
|
2MΩ
|
50MΩ
|
|||
|
The first effective
Range |
0.02MΩ~
10MΩ |
0.05MΩ~
20MΩ |
0.1MΩ~
50MΩ |
2MΩ~
1000MΩ |
accuracy
|
± 3% of the maximum scale value
|
|
|
accuracy
|
± 5% of the displayed value
|
Ground voltage
Range |
AC0~12V
|
||||
|
2nd Effective
Range |
10MΩ~
20MΩ |
20MΩ~
50MΩ |
50MΩ~
100MΩ |
1000MΩ~
2000MΩ |
|||
|
accuracy
|
± 5% of the displayed value
|
accuracy
|
± 3% of the maximum scale value
|
||||
|
voltmeter
Range |
AC0~600V
|
||||||
|
accuracy
|
± 3% of the maximum scale value
|
|
|||||
|
Safety specifications
|
IEC61010-1 (JIS C 1010-1) CAT. III 600V Pollution Level 2
IEC61010-2-031 (JIS C 1010-2-31) IEC61557 |
||||||
|
Suitable specifications
|
JIS C 1302-1994、JIS C 1304-1995
|
||||||
|
withstanding voltage
|
AC5550V/min
|
||||||
|
Using batteries
|
Single 3 dry battery R6P (1.5V) × 8
|
||||||
|
External dimensions
|
130(L)×183(W)×100(D)mm
|
||||||
|
weight
|
About 1000 grams
|
||||||
|
attachment
|
7103 (remote switch measuring probe), 8017 (elongated metal head), 7161 (flat test rod)
7131 (safety crocodile clip), wire box, shoulder strap, single 3 dry battery R6P (1.5V) × 8, user manual |
||||||
|
option
|
7100 (precision measuring line combination), 8016 (hook shaped metal head)
|
||||||
In stock recommendation: testo 476 stroboscope testo 206 PH meter