GermanyIntroduction to WTW inoLab Oxi 7310 Laboratory Desktop Dissolved Oxygen Analyzer
The inoLab Oxi7310 laboratory dissolved oxygen analyzer is a newer model that replaces the original Oxi 730. This instrument is very suitable for routine laboratory analysis and testing. Its interface is very intuitive, and the buttons and panel are easy to clean. Oxi 7310 can quickly and accurately provide measurements of dissolved oxygen, oxygen saturation, and oxygen partial pressure, whether used in environmental protection, chemical, pharmaceutical, medical, or for surface water and fishery measurements. inoLab ® The Oxi 7310 series offers a complete set of configurations with advanced features and ease of use. The intuitive user interface and easy to clean casing and keyboard are ideal choices for laboratories.
Advantages and Characteristics
◆ GLP file
◆ Accurate measurement of dissolved oxygen
◆ Intuitive user interface
◆ Operating comprehensive data recording(800 groups)
◆ Self stirring oxygen sensorStirrOx @ G interface (used for measuring BOD5)
◆ Standard type routine laboratory testing
◆ Automatic pressure correction
◆ Temperature compensation andOxiCal @ Quick Calibration
◆ Data logger, analog output and digital output RS232
◆ Transfer documents through USB interface
◆ Complete CSV format data transfer
◆ Optional built-in printer for data output
Product parameters
|
model |
inoLab ® Oxi 7310 |
|
Concentration range/accuracy |
0.00 ~20.00mg/L ±0.5%; 0~90mg/L ±0.5%; -2.000 ~19.999 ±0.005pH |
|
Saturation range/ accuracy |
0.0 ~200.0% ±0.5%; zero~600% ±0.5% |
|
Oxidative partial pressure |
0 ~200.0 hPa; 0~1250 hPa |
|
temperature |
-5.0℃~+105.0℃; ±0.1℃ |
|
Switching between ℃ and ℉ |
can |
|
AutoRead |
automatic |
|
Correction method |
Saturated moist air method, or manually input values according to other standards |
|
Correction record |
Last 10 times |
|
Built in pressure sensing probe |
have |
|
display |
Backlit LCD chart display |
|
reservoir |
500 sets (manual)/5000 sets (automatic) |
|
Recorder |
Manual or automatic recording |
|
interface |
Micro USB interface |
|
Printer (optional) |
Optional thermal printer, width 58mm |
|
power supply |
AC transformer; 4x1.5V alkaline battery or 4x1.2V rechargeable battery |
Standard configuration
|
1BA300 |
inoLab ® Oxi 7310 laboratory professional dissolved oxygen analyzer, only the main unit, including power adapter, bracket and operation manual, software and USB cable |
|
1BA300P |
inoLab ® Oxi 7310P laboratory professional dissolved oxygen analyzer, only for the host, with built-in thermal printer, power adapter, bracket and operation manual, software and USB cable |
|
1BA301 |
inoLab ® Oxi 7310 SET 1 laboratory professional dissolved oxygen analyzer, mainframe, including power adapter, bracket, CellOx ® 325 dissolved oxygen electrode, grinding disc, electrolyte, cleaning solution, replaceable dissolved oxygen film, software and USB cable |
|
1BA304 |
inoLab ® Oxi 7310 SET 4 laboratory professional dissolved oxygen analyzer, mainframe, including power adapter, bracket, StirrOx ® G dissolved oxygen electrode, grinding disc, electrolyte, cleaning solution, replaceable dissolved oxygen film, software and USB cable |