AllGear flow meterVS2The series is based on the principle of volumetric measurement, with the core component being a pair of high-precision meshing gears. When the measured medium flows through the flowmeter, the gear is driven to rotate under the pressure difference of the medium. Every time the gear rotates, a fixed volume of medium is discharged. By using sensors (such as magneto electric or photoelectric) to detect the number of rotations of gears, mechanical rotation is converted into electrical signals, and the instantaneous flow rate and cumulative flow rate are calculated by the signal processing unit. Its measurement accuracy is not significantly affected by changes in fluid viscosity, making it particularly suitable for precise measurement of high viscosity media
internal structure
The high-precision machining of the measuring chamber provides stable rotational space for gears, ensuring the accuracy of measuring volume
Gear pairs are usually two involute gears with the same module and equal number of teeth, made of wear-resistant materials (such as hardened steel or special alloys) to ensure long-term stable operation and minimal clearance leakage
The bearing system adopts high-precision rolling bearings or sliding bearings to reduce gear rotation resistance, improve measurement sensitivity and service life
The sealing components include shaft seals and chamber seals to prevent medium leakage and are suitable for different pressure and temperature conditions
The signal generator is installed at the end of the gear shaft and generates a pulse signal proportional to the gear speed through magnetic coupling or photoelectric induction, achieving non-contact measurement
Applicable Industries
Petrochemical industry: used for measuring and controlling media such as crude oil, lubricating oil, hydraulic oil, resin, coatings, etc
Automotive manufacturing: application in engine testing, transmission fluid circulation, and brake system hydraulic oil metering
Mechanical processing: monitoring the flow of metal cutting fluid and cooling oil to ensure lubrication and cooling effects during the machining process
Food and medicine: Suitable for precise transportation and measurement of high viscosity media such as edible oil, syrup, and liquid medicine. Models that meet hygiene standards can be used in pharmaceutical and food production
Energy industry: Flow monitoring and metering in fuel transportation and lubricating oil circulation systems
Hydraulic and Pneumatic: Measurement of Hydraulic Oil Flow in Hydraulic Systems to Ensure Stable System Pressure and Flow
parameter category |
specific parameters |
Nominal Diameter |
DN 4 mm - DN 50 mm(Depending on the model) |
flow range |
0.01 L/min - 1000 L/min(depending on the diameter and medium viscosity) |
accuracy class |
±0.1% FS(Standard type),±0.05% FS(High precision type) |
repetitiveness |
≤±0.03% FS |
Range of medium viscosity |
0.3 cSt - 1,000,000 cSt |
Operating Temperature |
-20°C - +120°C(Standard material), can reach+200°C(Special Material) |
work pressure |
400 bar(depending on diameter and material) |
output signal |
Pulse signal(NPN/PNP)The4-20 mATheRS485(optional) |
material |
Cast iron, steel, stainless steel(316L)Aluminum alloy (selected according to application scenarios) |
connection method |
Flange connection, threaded connection(NPT/BSP)Clamp connection |
Functional scope
Real time monitoring of instantaneous and cumulative traffic, supporting bidirectional traffic measurement
Provide multiple signal types for convenient communicationPLCTheDCSWaiting for control system integration
Suitable for various liquid media, including corrosive liquids (corresponding corrosion-resistant materials should be selected)
High temperature and high pressure adaptation. Special models can work stably under harsh temperature and pressure conditions
Low viscosity adaptability: By optimizing gear design, it is possible to measure as low as0.3 cStLow viscosity medium
The temperature range standard model operates at a temperature of-20°Cto+120°CWhen using high-temperature materials such as Hastelloy, it can be extended to-40°Cto+200°CTemperature changes may affect the viscosity of the medium, and the potential impact on measurement accuracy needs to be considered when selecting
The working pressure of conventional models is160 bar(DN 4-DN 25)Large caliber models(DN 40-DN 50)Usually it is63 barSpecial high-voltage models can reach400 barDuring installation, it is necessary to ensure that the system pressure does not exceed the rated pressure of the flow meter to avoid overload damage
The characteristics of the medium need to be clearly defined, including viscosity, corrosiveness, and the presence of particulate impurities. When containing particles, a filter should be installed to avoid gear wear
Flow stability: Avoid severe flow fluctuations and install buffering devices if necessary to ensure measurement accuracy
Installation direction: Usually installed horizontally, some models can be installed vertically (need to confirm the direction of the gear shaft to avoid gravity affecting the bearing life)
Upstream and downstream straight pipe sections: Although volumetric flow meters have lower requirements for straight pipe sections, it is recommended to retain them upstream5Double pipe diameter, downstream retention2Double diameter straight pipe section reduces flow field interference
Advantage performance
High precision measurement maintains stable accuracy over a wide viscosity range, especially suitable for high viscosity media
highly repetitive≤±0.03%Repeatability ensures data reliability
Compact and durable modular design, easy maintenance, long service life of gears and bearings
Wide range ratio can reach1:100Meet the requirements of different flow conditions
Strong anti-interference ability: insensitive to changes in medium density and temperature (within the rated range), less affected by flow field disturbances
Recommended features
Multiple material choices are made based on the characteristics of the medium, such as cast iron and stainless steel, to improve adaptability
Flexible signal output supports pulse, analog, and digital communication, facilitating system integration
Low pressure loss optimized flow channel design reduces system energy consumption
Easy to maintain, some models can replace gears and bearings online, reducing downtime
The strict production process and quality control of German manufacturing ensure long-term stable operation
Application field scenarios
Industrial process control: chemical reaction kettle feed metering, lubricating oil circulation system flow monitoring
Energy metering: fuel injection, hydraulic system energy loss analysis
Food processing: quantitative transportation of high viscosity materials such as chocolate and syrup
Automotive testing: dynamic monitoring of engine lubricating oil flow, transmission oil circulation testing
Pharmaceutical industry: precise proportioning and filling of drug solutions, in compliance withGMPstandard
Installation method
Choose flange, thread or clamp connection for pipeline connection according to the model to ensure good sealing and avoid leakage
The flow direction identification is strictly installed according to the flow direction arrow on the flowmeter housing. Reverse installation may cause measurement errors or damage to internal components
The installation position should avoid being installed at the outlet end of the pump (which is prone to air pockets). It is recommended to install it at the suction end of the pump or at a high point in the system to ensure that it is filled with the medium
Electrical connection signal lines need to be shielded to avoid electromagnetic interference and have reliable grounding
Precautions
Media filtration is installed upstream of the flowmeter100-200Eye filter to prevent solid particles from damaging gears
Ensure that the flow meter is filled with medium when starting the system to avoid idling, as idling may cause dry friction and wear on the gears
Regular calibration is recommended to be conducted once a year to ensure that the measurement accuracy meets the requirements
Maintenance: Regularly replace seals and bearings based on the characteristics of the medium to maintain the equipment in good condition
Low temperature start-up is necessary for high viscosity media. Preheating is necessary at low temperatures to avoid gear jamming caused by sudden increase in viscosity
German VSE gear flow meter spot parameters Shanghai Weite Rui
Advantage brand supply of Shanghai Weite Rui:
Beinlich Baili Pump
E+H: Mass flow meter, level gauge, electrode
Atos: Hydraulic valves, proportional valves, solenoid valves, amplifiers, hydraulic pumps
Kracht: Flow meter, gear pump, relief valve, indicator
VSE: flowmeter, amplifier
Rickmeier: Gear pump
MEISTER: Flow meter
Burkert: Flow meters, valves, sensors, etc
HYDAC: sensors, relays, hydraulic valves, filters, measuring instruments, etc
Wandfluh: Low temperature valve, plug-in valve, directional valve, pressure reducing valve, amplifier, coil, etc
LINCOLN: Distributor, directional valve, oil injector, metering pump