German Krom solenoid valve controller VG 25R02NT31D*

NegotiableUpdate on 05/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

German Krom Electromagnetic Valve Controller VG 25R02NT31D * $r $nKROM-SCHRODER Electromagnetic Valve KROM Proportional Valve KROM Combustion Controller KROM Filter, KROM Pressure Reducing Valve, KROM Pressure Gauge KROM Agent KROM Burner, KROM Electromagnetic Cut off Valve, KROM Air Gas Proportional Valve, KROM Burner Controller, KROM Ignition Transformer, KROM Flame Detector $r $n Full range of products in stock, please consult Shanghai Maoshuo Machinery Equipment Co., Ltd

Product Details

German Krom solenoid valve controller VG 25R02NT31D*

Krom Schroder, a German company founded in 1865, is a manufacturer of gas metering, gas safety, and control systems. Its products are widely used

In various combustion and heating fields involving gas. Krom products can account for 80% of the heating industry market in Europe. Kromschroeder Hochode AG

Being at the forefront of the world-renowned gas equipment manufacturing industry. Our business scope covers all areas of gas metering and control, providing customers with professional expertise in the heating field

Combustion system solution.

Krom Schroder has stable performance and comprehensive services. It is manufactured in Germany and has a global reputation. A trusted partner for numerous furnace OEM manufacturers.

Kromschroeder products can be widely used in various fields such as combustion and heating industrial furnaces, industrial boilers, flue gas analysis, and gas detection, with high-quality

Kromschroeder provides customers with components, intelligent system solutions, and services in an economical, safe, and environmentally friendly manner, while also conserving resources.

Main products of Krom Schroder in Germany:

Power switch, differential pressure switch, igniter, burner controller, valve, ignition transformer, combustion controller, burner, filter, electric actuator and flow rate

Calculation, etc.

Product features of Krom Schroder from Germany:

Krom Schroder automatic burner controller, flame controller can choose metal probe or UV photosensitive tube UVS1 to meet different environmental requirements

It can achieve automatic ignition, flame indication, shutdown alarm, and signal transmission for the burner to work automatically. This controller has a small size and weight

Light, strong ignition, sensitive response and other characteristics, it can be widely used in various industrial burners to monitor the flames generated by gases or liquids and provide flameout protection.

KROM-SCHRODER Electromagnetic Valve KROM Proportional Valve KROM Combustion Controller KROM Filter, KROM Pressure Reducing Valve, KROM Pressure Gauge KROM Agent KROM Burner, KROM Electromagnetic Cut off Valve, KROM Air Gas Proportional Valve, KROM Burner Controller, KROM Ignition Transformer, KROM Flame Detector

Please consult Shanghai Maoshuo Machinery Equipment Co., Ltd. for a large amount of stock of the entire series of products

Model: IFD 258-5/1W, IFD 258-10/1W, IFD258-3/1W

IFD 258-5/1WI、 IFD 258-10/1WI、 IFD258-3/1WI 等

(There are many models available, please contact us for detailed models)

Working voltage: 230V, 120V

IFD 258 is used to control the ignition and flame monitoring of burners, and can control burners with combustion air

It can also control atmospheric burners and participate in other control functions in conjunction with PLC. Burner controller and

The ignition transformer can be integrated into one ignition box, and our company can provide integrated supply

Functional Description

When the flame monitor is powered on, it enters the working state. If a flame is detected in the combustion device, the flame microampere signal sent back by the flame sensor is amplified through an internal amplification circuit to drive the relay inside the flame monitor. The relay nodes can be used to participate in more system control.

In a multi flame control system, all flame signals are interlocked and sent to PFU760 through another series of flame monitors to simultaneously control these burners

Gas pipeline safety and pressure stabilization system: including stabilizing valve, filter, shut-off valve, safety release valve, and pressure switch.

Electromagnetic valve series: including electromagnetic straight through valve and electromagnetic butterfly valve.

Electric gas shut-off valve series

Air/gas proportional valve

Electric gas regulating butterfly valve

Electric air conditioning butterfly valve: including normal temperature valve and high temperature valve.

Gas burner: including high-speed pulse burner, air preheating burner with radiation tube, gas burner with temperature regulating air, etc.

Suitable for combustible gases such as natural gas, liquefied gas, city gas, and mixed gas. Flame shapes: short flame, long flame, and flat flame.

Method for quickly determining the quality of solenoid valves on site

Firstly, check if there is a malfunction in the solenoid coil of the solenoid valve



Give the signal to open or close the two position valve on DCS, and then check whether the solenoid valve is powered on or off. Generally, listen to the sound on site. If you can't hear it, then there must be a problem with the coil. As for the solenoid valve itself, is there a problem? (Explanation below)

If there is a problem with the electromagnetic coil, first check the wiring to see if there is any loose connection or short circuit. If there is no problem with the wiring, it means that the electromagnetic valve coil is burnt out. Remove the wiring of the electromagnetic valve and measure it with a multimeter. If there is an open circuit, the electromagnetic valve coil is burnt out.


The reason is that the coil is damp, causing poor insulation and magnetic leakage, resulting in excessive current inside the coil and burning out. Therefore, it is necessary to prevent rainwater from entering the solenoid valve. In addition, if the spring is too hard, the reaction force is too large, the number of turns in the coil is too small, and the suction force is not enough, it can also cause the coil to burn out.


If the coil is good, it is a problem with the solenoid valve itself



Generally, the valve can be manually adjusted from 1 to 0 position using a straight line to open it. If it can be opened, it indicates that it is indeed a problem with the coil, and a new coil can be used. If it cannot be opened, the solenoid valve should be removed to see if the valve core is stuck or if there are impurities blocking it. If cleaning is correct, CCL4 should be used.


However, considering that there are no conditions on site, gasoline can be used, even if there is no water available. After cleaning, the on-site instrument air can be used to blow dry. When disassembling, it is important to remember the order of each component. If not careful, it is easy to make mistakes during installation. Even if you clean the solenoid valve properly, even if it is already open, it still cannot be opened!


German Krom solenoid valve controller VG 25R02NT31D*

KROM-SCHRODER Electromagnetic Valve KROM Proportional Valve KROM Combustion Controller KROM Filter, KROM Pressure Reducing Valve, KROM Pressure Gauge KROM Agent KROM Burner, KROM Electromagnetic Cut off Valve, KROM Air Gas Proportional Valve, KROM Burner Controller, KROM Ignition Transformer, KROM Flame Detector

Please consult Shanghai Maoshuo Machinery Equipment Co., Ltd. for a large amount of stock of the entire series of products