Gas VG solenoid valve
A Class A gas safety valve that complies with EN 161, used for automatic closing, closing when power is off, for gas and air, and has undergone EC type testing and certification.
DN: 6 to 65,
Connection: Double cone olive color, threaded or flanged,
PU: High value. 100, 200, 360, 500, 1000 or 1800 mbar,
Quick open, quick close or slow open, quick close,
Power supply voltage: 24 V DC, 120 V AC or 220/240 V AC,
Electrical connection: terminal or standard plug socket.
Provide the following versions:
Low noise valve,
With flow regulation
Valve, used for the production of methane by organisms
Valve with Viton disc seal.
PFU760 burner controller
Overview
Used for flame monitoring and burner control during gas or liquid fuel combustion;
Used for multi burner control when interlocked with other burner controls;
It can be directly controlled with 24VDC through a process computer;
Ionization or ultraviolet detection methods can be used;
Installation of 19 inch cabinet
Application scope:
This product can be widely used in various industrial burners in metallurgy, building materials, petrochemicals and other related industries to monitor the flames generated by the combustion of gas or liquid fuels; According to the requirements of different on-site conditions, UV detection or ionization detection methods can be selected. Suitable for flame monitoring and extinguishing protection in a single burner or combustion control system.
KROM-SCHRODER solenoid valve KROM proportional valve KROM combustion valve KROM control valve KROM pressure gauge KROM agent KROM pressure switch
Please consult Shanghai Maoshuo Machinery Equipment Co., Ltd. for a large amount of stock of the entire series of products
Krom Hochode TZI, TGI series ignition transformers: TZI5-15/20R, TZI5-15/100R, TZI7-25/20R, TZI7.5-20/33R, TZI7.5-12/100R. Krom solenoid valve VG25R02NT31D Hokode KROMSCRODER flame detector UVS5
G. Kromschroder AG, a German company with over 100 years of history, is a world-renowned manufacturer of gas combustion control system equipment. Its products include:
Gas pipeline safety and pressure stabilization system: including stabilizing valve, filter, shut-off valve, safety release valve, and pressure switch.
Electromagnetic valve series: including electromagnetic straight through valve and electromagnetic butterfly valve.
Electric gas shut-off valve series
Air/gas proportional valve
Electric gas regulating butterfly valve
Electric air conditioning butterfly valve: including normal temperature valve and high temperature valve.
Gas burner: including high-speed pulse burner, air preheating burner with radiation tube, gas burner with temperature regulating air, etc.
Suitable for combustible gases such as natural gas, liquefied gas, city gas, and mixed gas. Flame shapes: short flame, long flame, and flat flame.
Technical consultation,
On site installation guidance, equipment debugging, and supply of spare parts.
Testing method:
First, connect the controlled medium (pressurized liquid or gas<air>, with a pressure value in the middle range of the pressure range used by the solenoid valve) to the solenoid valve, and then energize the solenoid valve coil. If the controlled medium changes from on to off or from off to on, then the solenoid valve is good, otherwise there is a problem.
Common faults of solenoid valves include
First, use a multimeter to measure its continuity. If the resistance value approaches zero or infinity, it indicates that the coil is short circuited or open circuited. If the measured resistance is normal (about tens of ohms), it does not necessarily mean that the coil is good (I once measured the resistance of a solenoid valve coil to be about 50 ohms, but the solenoid valve could not operate, and everything was normal after replacing the coil). Please perform the following final test.
Find a small screwdriver and place it near the metal rod inserted into the solenoid valve coil. Then, apply electricity to the solenoid valve. If you feel magnetism, then the solenoid valve coil is good; otherwise, it is bad.
Fault phenomenon: If the solenoid valve has a plug/socket, there may be issues with the metal spring of the socket (which I have encountered before), wiring problems on the plug (such as connecting the power cord to the grounding wire), and other reasons that prevent power from being delivered to the coil.
It is best to develop a habit: after inserting the plug into the socket, tighten the fixing screw, and after the valve core rod, tighten the fixing nut on the coil.
If the plug of the solenoid valve coil is equipped with a light-emitting diode power indicator light, it must be connected correctly when driving the solenoid valve with DC power, otherwise the indicator light will not light up.
In addition, do not swap power plugs with LED power indicators of different voltage levels, as this may cause the LED to burn out/the power supply (switch to a low voltage level plug) to short circuit or the LED to emit very weak light (switch to a high voltage level plug).
If there is no power indicator light, the solenoid valve coil does not need to distinguish polarity (unlike transistor time relays with DC coil voltage and intermediate relays with DC coil voltage connected in parallel with diode/resistor leakage circuits, which are mostly original Japanese relays and require polarity differentiation).
Gas Filter GFK Series: GFK15, GFK20, GFK25, GFK32, GFK40, GFK50, GFK65, GFK80, GFK100, GFK125, GFK150, GFK200, GFK250。
Gas pressure reducing valve VGBF series: VGBF15R, VGBF25R,VGBF40R, VGBF40F, VGBF50F, VGBF50F, VGBF80F, VGBF100F, VGBF150F, VGBF200F, VGBF250F.
Safety shut-off valve JSAV series: JSAV25R40, JSAV40R40, JSAV40F40, JSAV50F40, JSAV80F40, JSAV100F40
Safety relief valve VSBV25R40
Air/Gas Proportional Control Valve GIK, GI Series: GIK 15, GIK20, GIK25, GIK40, GIK50, GI65, GI80, GI100, G1150
燃气电磁阀VG系列: VG6K03G, VG6K05 ,VG6RO5, VG8R03G,VG8R05, VG8R18, VG10R01, VG15/10R01, VG15/10R01G, VG10/15R02, VG15R02, VG10/15R03, VG15R03,
VG15/12R18,VG20R02,VG20R03, VG25R02, VG25R03, VG25/15R18, VG40/32R02,VG40R02, VG40F02,VG40R03,VG40F03,VG40/33R10,VG40/33F10,
VG50R02,VG50F02,VG50R03,VG50F03,VG50/39R10,VG50/39F10,VG50/65R02,VG50/65R03,VG65R02,VG65F02,VG65R03,VG65F03,VG65/49R10,VG65/49F10,VG80F02,VG80F03,VG100F02
Gas solenoid valve VGP series: VGP10, VGP15, VGP20, VGP25
Electrolux series VMR82, VMR72, VMRO, VMR1, VMR2, VMR3
Gas Combination Valve CG Series: CG, CG10, CG115, CG225, CG340, CG15, CG20, CG25, CG30, CG35, CG45
燃气电动阀VK系列: VK40R10T5A93D, VK40R40T5A93D, VK50R10T5A93D, VK50R40T5A93D,VK65R10T5A93D, VK65R31T5A93D, VK40F10T5A93D, VK40F40T5A93D,VK50F10T5A93D,
VK50F40T5A93D,VK65F10T5A93D, VK65F31T5A93D,VK80F10T5A93D, VK80F24T5A93D, VK100F10T5A93D, VK125F10T5HA93,VK150F10T5HA93, VK200F10T5HA93,VK250F05T5HA93,
VK50F80T5HG93D,
VK65F80T5HG93D,VK80F60T5HG93D, VK100F40T5HG93D, VK125F20T5HG93,VK125F20T5HG93, VK150F15T5HG93, VK150/100F40T5HG93, VK200F10T5HG93VK200/100F40T5HG93
Burner controller: Common model: IFS258-5/1W IFS 258-3/1W IFS258-10/1W
IFS244-5/1WI IFS 244-3/1WI IFS244-10/1WI
Model: IFD 258-5/1W, IFD 258-10/1W, IFD258-3/1W
IFD 258-5/1WI、 IFD 258-10/1WI、 IFD258-3/1WI 等
(There are many models available, please contact us for detailed models)
Working voltage: 230V, 120V
IFD 258 is used to control the ignition and flame monitoring of burners, and can control burners with combustion air
It can also control atmospheric burners and participate in other control functions in conjunction with PLC. Burner controller and
The ignition transformer can be integrated into one ignition box, and our company can provide integrated supply
Its products include:
Gas pipeline safety and pressure stabilization system: including stabilizing valve, filter, shut-off valve, safety release valve, and pressure switch.
Electromagnetic valve series: including electromagnetic straight through valve and electromagnetic butterfly valve.
Electric gas shut-off valve series
Air/gas proportional valve
Electric gas regulating butterfly valve
Electric air conditioning butterfly valve: including normal temperature valve and high temperature valve.
Gas burner: including high-speed pulse burner, air preheating burner with radiation tube, gas burner with temperature regulating air, etc. Suitable for combustible gases such as natural gas, liquefied gas, city gas, and mixed gas. Flame shapes: short flame, long flame, and flat flame.
German Krom Hokode Electromagnetic Valve Controller VG 8R03T6*
KROM-SCHRODER solenoid valve KROM proportional valve KROM combustion KROM control valve KROM pressure gauge KROM agent
Please consult Shanghai Maoshuo Machinery Equipment Co., Ltd. for a large amount of stock of the entire series of products