- Phone
-
Address
No. 1-212 Juhe Sixth Street, Jufuyuan Industrial Park, Tongzhou District Economic Development Zone, Beijing
Beijing Jinfuhong Technology Co., Ltd
No. 1-212 Juhe Sixth Street, Jufuyuan Industrial Park, Tongzhou District Economic Development Zone, Beijing
Generator AC voltage withstand tester
Generator AC voltage withstand tester
The XT-100 portable generator AC (DC) withstand voltage tester cleverly adopts the compensation principle of inductor current to capacitor current in electrical principles. On the basis of ensuring that the power frequency and waveform remain unchanged, it greatly reduces the number of test equipment components and the weight of the test instrument, reducing the total weight of the test equipment from several hundred kilograms or even a few tons in the past to 120 kilograms now. The portable generator AC (DC) withstand voltage tester has truly achieved the effects of being lightweight, safe, and efficient through on-site testing. Replacing the cumbersome and cumbersome experimental equipment of the past,Greatly reduces the workload on site.Moreover, the instrument is equipped with a DC withstand voltage test function, which allows for the DC withstand voltage test of the generator when on-site conditions permit, providing great convenience for electrical testing personnel and testing work in power plants.
Equipment advantages:
|
1. Lightweight equipment:
2. Easy to operate; 3. Do not generate resonance overvoltage and capacitance overvoltage; |
4. The required power capacity for the experiment is small:
5. The voltage waveform is not distorted; 6. The instrument is compatible with both AC and DC, and has good completeness;
|
maintechnical indicators
|
Rated output voltage: 0~50kV; High output current: 3A/50kV; Rated capacity: 150kVA Output frequency: 50Hz Test frequency: 50Hz ± 5 (power frequency range); Resonant voltage waveform: Chord wave, waveform distortion rate<1.0% Quality factor: 30~80 Work system: Under full power output, a continuous working time of 15 minutes per operation
|
Environmental temperature and relative humidity: -10℃~+40℃; <90%, no condensation condition Working power supply:Power supply voltage: AC220V ± 10% Power frequency: (50 ± 1) Hz Working method:Manual boosting, zero position self-locking display modeTwo types: pointer and digital display automatic protectionAutomatic overcurrent protection, timed sound and light alarm Timing range:0-99.9 s (M H) accuracy: 0.5% |
Complies with the requirements of GB50150-2006 Electrical Equipment Handover Test Standard for Electrical Equipment Installation Engineering, DL/T596-2005 Preventive Test Code for Power Equipment, and DL/T848.2-2004 General Technical Conditions for High Voltage Test Devices - Power Frequency High Voltage Test Devices
Comparison with other voltage withstand test methods
instrument name |
Power frequency AC test transformer |
Variable frequency series resonance test device |
Lightweight generator power frequency AC voltage tester |
Method Principle |
Traditional electromagnetic induction method |
Series resonance technology |
Parallel compensation technology |
Weight and Volume |
3-5 tons |
200~400Kg |
120Kg |
Comparison of advantages and disadvantages |
High current and high voltage require the use of a large power supply during testing. The equipment is bulky, expensive, and inconvenient to operate |
The tuning process is inconvenient, and the test boost process is not smooth enough; During the process of tuning and boosting, it is easy for the voltage to suddenly rise and burn out the equipment, and the test frequency cannot be guaranteed to be the power frequency; Secondly, DC withstand voltage test cannot be conducted |
Functional integration, easy operation, small size, light weight, ensuring that the test frequency is at the power frequency, ensuring equipment safety during the experimental process, and capable of conducting DC withstand voltage tests when site conditions permit |
Model configuration parameters
Example of Model |
Parameters of the tested generator |
Main Configuration |
||||
|
Rated capacity (MW) |
rated voltage (kV) |
capacitance (μF) |
power supply |
excitation transformer |
Resonant reactor |
|
|
XT-100/30 Output voltage: 30kV Test capacity: 80kVA |
200 |
15.75 |
0.19-0.21 |
1 unit of 10kW |
1 unit of 10kVA |
32kV/2A one unit |
|
XT-100/40 Output voltage: 40kV Test capacity: 80kVA |
300 |
18 |
0.18 |
1 unit of 10kW |
1 unit of 10kVA |
One 36kV/2A unit |
|
XT-100/50 Output voltage: 50kV Test capacity: 125kVA |
600 |
20 |
0.2 |
1 unit of 10kW |
1 unit of 10kVA |
40kV/2.5A one unit |