Gas explosion-proof electronic platform scale display
The XK3150-Ex-P intrinsically safe printed weighing instrument adopts a 24 bit high-precision A/D converter, with an internal resolution of over 2 million and an external resolution of one in 100000. It can be configured on high-precision electronic scales and has strong anti-interference ability; The weighing platform structure is available in carbon steel and stainless steel options; The waterproof type of the stainless steel waterproof structure shell can reach IP67; Specially designed for gas explosion-proof environments; Explosion proof grade: Ex iC Ⅱ C T3/T4 GC is widely used in fields with explosion-proof requirements such as petroleum, chemical, and pharmaceutical industries;

Technical Specifications:
◎ 304 stainless steel casing
◎ Display: 6-digit 20mm LED digital tube or 25mm LCD with backlight display
Accuracy level: Level III
◎ Explosion proof mark of the system: ExicIIBT3/T4GC
◎ Power supply: intrinsically safe output power supply AC220V 50/60 Hz
DC: intrinsically safe battery pack DC7.4V/4.0Ah
◎ Working temperature: -10 ℃~+40 ℃, relative humidity: ≤ 80% RH
◎ Communication interface: RS232, RS485

LP7350-S9 intrinsically safe output power supply
Shell: ABS Explosion proof rating: Ex [ib] IIC
Input power supply: AC220V 50Hz
Output voltage: DC9V
Output voltage line length: 15m
Usage area: Safe

LP7350-H9 Explosion proof Output Power Supply (Optional)
Shell: Aluminum alloy die-casting
Explosion proof grade: Exd IIB T4
Input power supply: AC220V 50Hz
Output voltage: DC9V
Output voltage line length: 15m
Usage area: Hazardous area

DE001 intrinsically safe battery and charger (optional)
Shell: Stainless steel Explosion proof grade: Ex ib IIC T3
Output voltage: DC7.2V
Battery capacity: 4800mAh
Usage area: Hazardous area, explosive gas environment Zone 1, Zone 2, Class IIC gas
Attention: Charging must be carried out in a safe area

XK3150-Ex-PGas explosion-proof electronic platform scale display