Gas chromatography (quadrupole) mass spectrometry GC thermal analyzer ionization source CI

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

GC-MS3200 gas chromatograph (quadrupole) mass spectrometer gas chromatograph mass spectrometer is widely used in environmental protection industry, electronics industry, textile industry, petrochemical industry, essence and spice industry, pharmaceutical industry, agriculture, food safety and other fields; Organic pollutants in the environment. Gas chromatography (quadrupole) mass spectrometry GC thermal analyzer ionization source CI

Product Details

Gas chromatography (quadrupole) mass spectrometry GC thermal analyzer ionization source CI

气相色谱(四极)质谱GC 热解析仪 学电离源CI

1、 Product testing

·The brand new industrial appearance design, simple and elegant GC operation panel with ingenuity, will give you a different operating experience, and the details are protected against misoperation.

·EPC gas path control: The third-generation EPC control gas path unit can choose constant pressure mode or constant current mode, and the program intelligent control of the purge valve minimizes sample diffusion and loss; Optional split/non split injection method, suitable for various application environments; The intelligent solar term function can effectively reduce operating costs; The instantaneous switching technology of the non dead volume valve solves the problem of long pressure stabilization time after valve switching in similar instruments without split injection, effectively improving chromatographic peak shape and ensuring retention time repeatability.

·The optimized GC temperature control system has improved the temperature control accuracy of the column box to ± 0.03 ℃, and the repeatability has been greatly improved. The preset installation positions for nitrogen, hydrogen, and air paths can be used to install other chromatographic detectors according to user needs. The improvement of program temperature repeatability enables the heavy components in the oil to obtain sharper chromatographic peaks.

·The CI reaction gas flow feedback control module can automatically adjust the reaction gas flow rate according to the preset proportion of target ions in the gas, so that it is at a flow value, saving reaction gas while ensuring the repeatability of CI analysis.

·A simple and practical liquid and solid direct injection rod option that can quickly obtain structural information of unknown substances is a powerful tool for chemical synthesis practitioners. The external rapid heating kit ensures uniform and rapid heating of the sample tube of the injector. The vacuum lock valve core manufactured by special technology has undergone 5000 fatigue tests and reliable sealing. The operating temperature reaches 650 ℃.

·Compatible with standard specifications of traditional GC chromatography columns.

·An automatic sampler can be optionally selected.

·Multiple optional peripheral accessories: The software includes a complete configuration module that allows for easy switching between the external components you need to control, such as the purge and capture concentrator, liquid automatic sampler, thermal analyzer, headspace sampler, etc. At the same time, the additional DO port meets the requirements for other controls.

2、 Performance parameters

working conditions

power supply

220V,50Hz

temperature

Operating environment 15 ℃ -35 ℃

humidity

Operating status 25% -80% (RH)

performance parameters

gas chromatograph

temperature stability

≤±0.03℃

heating rate

40℃/min

runtime

999.99min

14th order program temperature rise

Split/Non Split Injection Port (3rd Generation Electronic Gas Control, EPC)

temperature

400℃

Electronic parameter settings for pressure, flow rate, and diversion ratio

Pressure setting range

0 - 999 kPa

flow range

0 - 200mL/min

Automatic sampler (optional)

Mass spectrometer detector

Main performance indicators

Quality Scope

1.5 - 1024 amu

Quality axis stability

Better than 0.10amu/48h

resolution

Unit Mass Resolution

sensitivity

DB-5MS 30mx0.25mmx0.25um elastic

English capillary column or similar column

EI source, full scan: (scan range: 100-300 amu)

1pg Octafluoronaphthalene (OFN) signal-to-noise ratio ≥ 100:1

scan rate

10000 amu/s

dynamic range

10 5

ion source

Electron bombardment ionization source (EI)

Learn ionization source (CI), optional

Dual filament

program switching

Filament current

3A

Emission current

(10-350) µ A adjustable

Ionization energy

(5-150) eV adjustable

Ion source temperature

Independent temperature control, adjustable from 150-320 ℃

Quality Analyzer

Imported metal quadrupole

Equipped with full scanning and selective ion detection acquisition functions

Up to 128 sets of ion detection (SIM) can be selected

Each group can select up to 128 ions

detector

Electron multiplier+high-energy focusing component for hitting the pole

Gas chromatography-mass spectrometry interface

Transmission line independent temperature control, adjustable from 150-320 ℃

vacuum system

Molecular turbo pump (250L/s), mechanical pump (180L/min)

Wide range composite cold cathode gauge

data processing system


software

Chinese/English optional, real-time acquisition workstation and MS3200 software system

Optional Accessories

DIP110 Liquid/Solid Direct Injection Component

Blow sweep capture concentrator

Thermal analyzer

Dynamic headspace sampler

Technical Service

Provide one set of free operation manual (Chinese/English optional)

Free one-year warranty from the date of qualified installation and commissioning of the instrument

Free on-site installation, debugging, and training for users

Can provide factory practical training


3、 Application scope (the most flexible configuration solution)

1. Configuration applied in the field of water quality testing

(Applicable EPA Method 502.2, HJ639-2012)

Combined use of blowing, sweeping, and capturing+GC-MS 3200+MS3200 software package+DB-624

(30m × 0.25mm × 1.4 µ m) quartz capillary column

Headspace combination+GC-MS 3200+MS3200 software package+DB-624

(30m × 0.25mm × 1.4 µ m) quartz capillary column

Suitable for quantitative detection of volatile organic compounds in surface water, drinking water, and source water.

2. Economic configuration applied to environmental air quality monitoring

Domestic EW-3TD thermal analyzer+GC-MS 3200+MS3200 software package+equivalent DB-5MS chromatographic column (30 m x 0.25 mm x 0.25 µ m) medium polarity column

Suitable for air quality testing in indoor environments and public places, with sensitivity to common harmful gases such as TVOC.

3. Typical configuration for routine laboratory analysis

Automatic sampler+GC-MS 3200+MS3200 software package+DB-5MS

(30m × 0.25mm × 0.25 µ m) quartz capillary column

It is applicable to the qualitative and quantitative analysis of most organic substances, such as essence, spices, pesticides, and PAHs.

4. Applied to quality monitoring in chemical synthesis processes

DIP110+GC-MS 3200+MS3200 software package+DB-5MS

(30m × 0.25mm × 0.25 µ m) quartz capillary column

Suitable for rapid qualitative analysis of intermediates and final products in the field of chemical synthesis, combined with GC injection for precise quantification.

5. Vehicle mounted mobile laboratory configuration for mobile monitoring

The analytical capabilities of the laboratory have been transferred to mobile laboratories for emergency monitoring in food safety and environmental pollution incidents, enabling rapid screening of chemical pollutants.

Gas chromatography (quadrupole) mass spectrometry GC thermal analyzer ionization source CI