GYT101 Trace Flammable Liquid Detector

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Used for rapid and accurate detection of volatile gases in flammable organic liquids or flammable gases contained in the air (including gasoline, kerosene, diesel, alcohol, paint thinners, and organic solvents)

Product Details

GYT-101 Trace Flammable Liquid Detector

GYT-101 Trace Flammable Liquid Detector is used to measure the vapor concentration of gasoline, kerosene, diesel, and various organic solvents. Measurement method: diffusion principle: gas sensitive semiconductor (using specialized imported components) Measurement of gases: gasoline, kerosene, diesel, and various organic solvents vapors Measurement range: 0-1999.0ppm (isobutane) Sensitivity; 50ppm display: 3 1/2 LCD digital display (LCD) alarm mode: red LED flashing, intermittent and rapid buzzing sound preheating time: after preheating for 2 minutes, the buzzing sound can be slowly adjusted to zero after 5 minutes. Operating temperature: -10-40 ° C Power supply: 3.6V lithium battery long-term pressure alarm; Green LED lights up, buzzer emits sound size: 125 × 62 × 26mm (HxDxW)


GYT-101+Trace Flammable Liquid Detector

The volatile gases of flammable organic liquids or flammable gases contained in air, such as liquefied petroleum gas, natural gas, methane, toluene, coal gas, biogas, natural gas, methane, hydrogen, coal gas, sulfides, acetone, gasoline, kerosene, alcohol/ethanol, oxides, etc., can be detected by natural diffusion method, and are waterproof, dustproof, and explosion-proof. Detection range: 0~10000 μ mol/mol (ppm) Resolution: 1 μ mol/mol (ppm) Applicable range: Flammable volatile gases or combustible gases Alarm point: Can be manually set, default low alarm value is 500 μ mol/mol (ppm), high alarm value is 2000 μ mol/mol (ppm) Response time: T<30 seconds Indicator: LCD real-time data display, system status light-emitting diode, sound, vibration indicator alarm and low battery boost Working environment: Temperature -20 ℃ 50 ℃ Humidity<95% RH No condensation Working voltage: DC3.7 V (lithium battery) Explosion proof mark: ExibIIBT3Gb


GYT-101plus portable trace flammable liquid detector

GYT-101plus portable trace flammable liquid detector is used to quickly and accurately detect volatile gases of flammable organic liquids or flammable gases contained in the air (including gasoline, kerosene, diesel, alcohol, paint thinner, organic solvents and other flammable gas components). It has a built-in suction pump for measurement and can be switched to diffusion or diffusion+pump suction detection methods. The instrument is equipped with a 200mm flexible sampling probe at the front end, which is particularly suitable for detecting flammable liquids or gas residues in narrow or crevice areas during fire investigation work.

Detection type: volatile gases of flammable organic liquids or flammable gases contained in the air (including flammable gas components such as gasoline, kerosene, diesel, alcohol, paint thinner, and organic solvents); Detection method: Built in pump suction, switchable between diffusion and diffusion+pump suction detection methods; Detection range: 0-2000ppm; Resolution: 1ppm; Detection accuracy: Typical accuracy: ≤± 3% FS (optional high-precision sensor); Detection principle: catalytic combustion; Display unit: ppm or% VOL; Device lifespan: 2-3 years; Display content: LCD displays real-time concentration, unit, gas name, alarm status, time, storage status, communication status, battery level, charging status, etc; Response time: T90 ≤ 20s; Battery capacity: DC3.7Vx2 2500mA rechargeable polymer battery with overcharge, overdischarge, overvoltage, short circuit, and overheating protection functions; Charging interface: Standard Type-C (fully charged in 2 hours); Data storage: standard capacity not less than 100000 records; Support local viewing, deletion, or data export, with arbitrary storage time intervals; Explosion proof type: Exia II CT4Ga intrinsic safety type; Protection level: IP68 dustproof, rainproof, immersion proof, and corrosion-resistant.


AT1500 flammable liquid detector; Dangerous liquid detector

Quickly determine whether the liquid belongs to prohibited dangerous goods without opening the container. Detectable types include gasoline, kerosene, diesel, ethylene glycol, isopropyl ether, petroleum ether, acetonitrile, ethylene glycol, nitrobenzene, epichlorohydrin, n-heptane, turpentine, acetone, benzene, toluene, xylene, dichloroethane, ethanol, isopropanol, n-octane, carbon disulfide, methanol, nitromethane, n-hexane, trilv methane, paint thinner (solvent for nitro thinner), paint, styrene, cyclohexanone, cyclopentane, diethylamine, n-pentane, tert butanol, methyl methacrylate, n-propanol, cyclohexane, methyl tert butyl ether, 1,4-dioxane, dipentene, acetaldehyde, pyrrole More than forty flammable and explosive hazardous liquids, including alkanes. Startup time: 1 second; Analysis and testing time: about 1 second. Can detect container size: not less than 5.5cm * 1.5cm, minimum capacity 50ml. Alarm method: sound alarm, and LCD alarm. Human machine interface: provides a fully Chinese interface, self luminous OLED screen display data storage: provides liquid detection result storage and retrieval function, with a storage capacity of not less than 10000 tests, and can export data through USB interface. Composition: Host, charging base, etc. Composition dimensions and weight: L216xW50xH79mm, approximately 200g (including battery)


Oil based test paper, oil based test paper

Can detect whether the liquid is a petroleum product, used for rapid testing of petroleum ether in water or soil (40-80 ℃); Gasoline (high octane); Fuel oil; The oil content of lubricating oil. Color response: When the test paper comes into contact with hydrocarbons, especially gasoline, fuel, lubricants, etc., its color will turn dark blue.


Combustible gas rapid detection tube

Used to determine the presence of flammable gases or combustion aid components such as gasoline, ethanol, methanol, liquefied petroleum gas, natural gas, etc. on site, with a total of five testing types and equipped with detection samplers.


Other fire detection equipment series:

VC11 fire alarm system function testing box; VC11A automatic sprinkler system and fire hydrant system function testing box; VC11B smoke control system function testing box; VC11F Fireproof Coating Testing Box Series; VC11N electrical fire monitoring system on-site detection box; VC11Q fire investigation lighting equipment box/fire scene investigation light source equipment box; VC11P Electrical Safety and Hazard Detection Instrument Set; VC11T fire investigation and detection equipment box/fire scene investigation and detection box; VC11Z portable fire inspection toolbox; VC12/VC12J Building Fire Protection Equipment Testing Box Fire detection instrument kit box; VC12D building fire protection equipment testing box; Fire supervision and acceptance inspection box; VC12F construction project fire acceptance box/fire housing acceptance equipment box; VC12X Building Fire Protection Facility Maintenance and Inspection Equipment Box; VC12W national standard fire protection facility maintenance and testing equipment kit box; VC13A fire inspection and fire investigation instrument box; VC13b fire detection instrument box; VC13C fire accident investigation equipment box Fire investigation instrument box; VC13d Fire Scene Investigation and Demolition Toolbox; Fire scene evidence extraction module box; VC13F fire scene investigation equipment box; VC13G Fire Scene Investigation Toolbox; VC13H fire scene investigation and evidence extraction box; VC13J fire site closure warning isolation equipment box; VC13K Forest Exploration Box; Fire scene investigation and dismantling toolbox; Forest Fire Investigation Toolbox; VC13S Forest Fire Site Investigation Box; Forest fire investigation box; VC13T Fire Supervision and Inspection Package (Fire Prevention and Control Joint Logistics Equipment Package); VC13U Anti Fire Joint Logistics Equipment Package/Box; VC13X fire supervision equipment box; VC13Y fire supervision and inspection equipment box; VC13Z fire supervision and inspection equipment box; VC14 airport fire inspection equipment box; VC15A fire electrical fire detection instrument box; VC15C fire electrical testing box; VC15F hazardous area electrical explosion-proof safety detector material box; VC16A fire protection product quality on-site detector box; VC16B fire protection product on-site testing box; VC16D Fire Product Inspection Equipment Box; VC17 fire scene environmental detection box; Emergency toxic and harmful gas detection box; VC17A fire safety officer carrying box, fire safety officer control box; VC18 series fire supervision technology equipment box; VC19F subway fire detection box; VC45 Thin Layer Chromatography Analysis Device; VC46 flame retardant color development device; VC47 fire scene physical evidence extraction device box; QC-12 Gas Evidence Extraction and Preservation Kit (Gas Sample Collection Box); GQ-12 Solid Evidence Extraction and Preservation Kit (Solid Sample Collection Box); YQ-12 Liquid Evidence Extraction and Preservation Kit (Liquid Sample Collection Box); HC-1 Fire Scene Investigation Consumables Toolbox; HC-2 Fire Site Investigation Consumables Kit; HWZ-1 Fire Scene Evidence Packaging Box; HWZ-2 Fire Scene Evidence Extraction Device; PC-2 Fire Door Disassembly Tool Box; WCA-8 on-site inspection electric tool set; QY-3 sampler; Gas Solid Liquid sampling kit; HCX200 Fire Investigation Site Combination Disassembly Tool; PC-8 fire scene combination manual dismantling toolbox; FJ-15 Fire Scene Investigation Medical First Aid Kit; FJ-16 fire scene closure warning equipment box.