Welcome Customer !

Membership

Help

Shanghai Gaotian Pump Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

GTGW Non Negative Pressure Water Supply Equipment (Box Type)

NegotiableUpdate on 02/24
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Product Name: GTGW Variable Frequency Speed Control Non Negative Pressure Water Supply Equipment Model: GTGW80/40-2C Product Category: Series Water Supply Equipment → GTGW Variable Frequency Speed Control Non Negative Pressure Water Supply Equipment Caliber Range: DN40-150 Flow Range: 0.4-180m3/h Head Range: 9-305m Our Advantages: In stock, special materials can be customized, product performance is stable, service life is more than 5 years Selection Quotation: You only need to provide the number of households in the community and the number of floors, and we can provide you with a selection quotation
Product Details
GTGW Variable Frequency Speed Control Non Negative Pressure Water Supply Equipment



1. Scope of application: Suitable for pressurized water supply in areas with sufficient pressure in urban pipeline networks;


2. Applicable engineering types: production and domestic water for industrial and mining enterprises, large intermediate booster pump stations for water supply in water plants;


3. Applicable engineering location: secondary pressurization system for water supply;


4. Other applicable scope: Domestic water supply for newly built, renovated, expanded residential buildings, office buildings, hotels, restaurants and other public buildings;


5. Types of using units: design unit, construction unit, supervision unit.


2、 Product Overview:

The traditional water supply method cannot do without reservoirs, and the water in reservoirs is usually supplied by the tap water network. In this way, pressurized water enters the reservoir and becomes zero, resulting in a large amount of energy waste. The GTGW variable frequency speed regulation non negative pressure water supply equipment is a complete set of water supply equipment developed by our professional technical personnel on the basis of pneumatic water supply equipment, which can be directly connected to the tap water pipe network and does not have any negative effect on the tap water pipe network. It can replace reservoirs and fully utilize the pressure of the tap water network to directly or indirectly supply water, avoiding secondary energy waste and pollution, significantly saving infrastructure investment and shortening construction period. The GTGW variable frequency speed regulation non negative pressure water supply equipment consists of an intelligent variable frequency control cabinet, a steady flow tank, a water pump unit, a table, valves and pipelines, a base, etc. It is suitable for all water supply systems that require increased water pressure and constant flow.

If you have any questions about the above structure, you can call 021-57239999 orClick to consult experts for selection and quotation

3、 Product Usage:

The GTGW series variable frequency speed regulation non negative pressure water supply equipment can be used for domestic water supply and also for fire water supply. It can be equipped with any type of water pump. When the equipment is used for fire protection, it is recommended to equip it with a fire specific water pump.

4、 Product advantages:

1. Energy saving (more energy-efficient)

No environmental pollution, more energy-efficient, saving over 30% more energy than typical water supply equipment.

2. Stable and reliable

Danish Grundfos or Southern Water Pump is used, and Schneider Electric is used for low-voltage electrical appliances. Multiple water pumps are used for operation, and the failure of a single pump does not affect normal water supply.


3. Intelligent control

Fully automatic intelligent operation, no need for personnel management, cost saving, worry free and labor-saving. The control core adopts ABB frequency converter and PLC control.


4. Flexible and convenient

The device is compact, easy to install, and easy to maintain.

5. Environmental Protection

Adopting austenitic stainless steel SUS304 food grade material, there is no secondary pollution, no need for cleaning, and meets the hygiene requirements for direct drinking.


5、 Equipment Introduction

1. It is to integrate the water tank and water pump used in the water supply system of the tap water pipeline, so that the water pump, control cabinet, non negative pressure device and other equipment are placed in the water tank, and the equipment is isolated from the water in the water tank through the water tank partition. The placement of the water pump inside the water tank greatly reduces the noise of the equipment.


2. The inlet of the variable frequency pump is connected to the non negative pressure device and the non negative pressure water device. When the pressure is sufficient, the non negative pressure device automatically opens, and the water is directly supplied by the municipal pipeline network, which is then pressurized by a booster pump to supply water to the user. When the non negative city device detects a decrease in pressure in the municipal pipeline network, the non negative pressure inlet device immediately starts and the non negative pressure device closes. At this time, the user pipeline is directly pressurized by pumping water from the water tank through the booster pump to ensure sufficient pressure in the user pipeline.


3. The inlet of the water tank of the non negative pressure variable frequency water supply equipment adopts an intelligent solenoid valve to control the inlet pressure and water level. When the pressure in the pipeline decreases and the booster pump draws water from the water tank, intelligent control can be used. When the water level in the tank is below a certain level, the solenoid valve can be opened to release water from the pipeline, ensuring a certain pressure at the water intake. This measure can avoid peak water consumption and play a peak shaving role. It also avoids zero pressure discharge from ordinary water tanks, which is a good protection for pipeline pressure.


4. The water tank, water pump, pipelines, valves and other water related materials in this complete set of equipment are all made of food grade stainless steel materials, which will not cause secondary pollution to tap water. At the same time, the equipment is equipped with an intelligent circulation system, which automatically draws water from the water tank every 6 hours to ensure fresh water quality, hygiene and environmental protection.


6、 Equipment installation requirements:


1. Tighten the anchor bolts to prevent vibration during start-up from affecting the performance of the pump.


2. Install regulating valves on the inlet and outlet pipelines of the pump, and install pressure gauges near the pump outlet to control the pump's operation within rated conditions and ensure its normal use.


3. If a check valve is installed in the discharge pipeline, it should be installed outside the gate valve.


4. The installation methods of non negative pressure water supply equipment pumps are divided into rigid connection installation and flexible connection installation.


5. Before installing the non negative pressure water supply equipment, carefully check whether there are any hard objects inside the pump body to avoid damaging the impeller and pump body during operation


6. When installing non negative pressure water supply equipment, it is not allowed to add pipeline capacity to the pump to avoid deformation and affecting normal operation.


7、 Installation and Debugging

1. The basic dimensions on site should be constructed according to the foundation drawing provided by our company, and its position and elevation should comply with the engineering design and water conservancy requirements; When pouring cement slurry for the second time, it should meet the horizontal requirements, and its longitudinal and transverse levelness should not exceed 0.1%

2. After the equipment is installed in place, all fasteners should be tightened, and the equipment should be carefully checked for any running or dripping water to avoid water leakage caused by transportation vibration.

3. The power supply incoming line requires a three-phase five wire system, with a voltage requirement of AC380, ± 10%. If there is a leakage protection switch at the power supply incoming line end, the leakage current must be greater than 500MA. Otherwise, during frequency conversion operation, the user will trip in the air (because the frequency converter is a power element composed of multiple components).

4. After the equipment is powered on, manually set the machine and adjust the forward and reverse rotation of each pump; If it is reversed, the corresponding input two-phase power supply can be switched. If it is reversed during frequency conversion, change the frequency converter parameter 1003 to 1 or 2 for switching (ABB frequency conversion).

5. When adjusting the automatic mode, attention should be paid to the wiring of the corresponding numbers of the three protectors. The leakage protection switch at the bottom of the tank is normally in the open state with water and closed state without water. Before wiring, use a multimeter to check.

6. The equipment parameters are fully digitized in Chinese. When setting values, attention should be paid to the protection value for low tap water inlet and the acceleration time of the frequency converter, sleep time, timed pump cut-off time, and positive and negative pump cut-off differences. They are all set at the factory. If there are special requirements on site, please consult our technical department.

8、 Fault causes and troubleshooting methods

event block

primary follow

solution

Excessive startup load

The outlet valve was not closed during startup

Close the valve and restart

Excessive current during operation

1The clearance between the pump impeller and the pump casing is too small, resulting in friction

2Inhaling debris into the pump

3Bearing wear and tear

4Excessive flow and low head

5Bending of pump shaft

6The clearance between the couplings is too small

7The voltage is too low

1Check the clearance between the impeller and repair it

2Disassemble and remove debris

3Replace damaged bearings

4Close the outlet valve appropriately

5Remove the shaft for straightening

6Adjust the gap again

7Poor contact of contactor contacts

Equipment vibration

1Loose bolts

2Bearing wear or damage

3The coupling is not concentric

4Unbalanced pump shaft or motor shaft

1Tighten the bolts

2Replace bearings

3Align the coupling

4Straighten or replace the pump shaft or motor shaft

Bearing overheating

1Bearing damage or looseness

2Incorrect installation of bearings

3Poor lubrication of bearings or inconsistent oil quality

4The shaft is bent or the coupling is not concentric

5The impeller loses balance

1Replace or adjust bearings

2Reinstall and adjust the gap

3Clean the bearings and refill them with oil

4Straighten the pump shaft or coupling and realign it

5Clean the debris in the impeller balance hole

The pressure gauge has a pressure display,

But there is no water at the outlet

1The pipeline configuration is too small and the resistance is too high

2Is the water pump reversing

3Is the impeller inlet and flow channel blocked

1Overhauled or modified the water outlet pipe

2Switching of pump motor phase lines

3Remove debris from the pump

Insufficient traffic

1Wear of the mouth ring and excessive clearance with the impeller

2The outlet valve is not fully opened or damaged

3Pipeline leakage

1Replace the mouth ring

2Fully open the outlet valve or replace it

3Repair or replace the water supply pipe

The water pump cannot sleep

1Pipeline leakage

2The system pressure setting value is too high

3The water pump runs idle without water

4The sleep limit is set too low

1Check and eliminate leakage points

2Adjust the set values again

3Check the inlet of the water pump

4Reset the sleep limit

9、 GTGW Variable Frequency Speed Control Non Negative Pressure Water Supply Equipment (Carbon Steel) Model Meaning:

11、 Here are some model examples:

Related articles