GPR-1800 AII online explosion-proof trace oxygen analyzer

NegotiableUpdate on 12/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

GPR-1800AII online explosion-proof trace oxygen analyzer AII online oxygen analyzer includes GPR-1500

Product Details

GPR-1800 AIIOnline explosion-proof trace oxygen analyzer

AIIThe online oxygen analyzer includes GPR-1500,GPR-2500,GPR-1600,GPR-2600,GPR-1900, GPR-2900, GPR-18,GPR-28, GPR-1800, GPR-2800, GPR-7900
The AII GPR-1800 AIS ATEX explosion-proof trace oxygen analyzer from the United States is a product certified by the ATEX 94/9/EC directive (see all ATEX certified products). The PPM oxygen sensor can accurately measure oxygen concentrations ranging from 100 PPB, with a working life of over 24 months to 1%. It has menu driven control and dual point selectable alarm setpoints.

GPR-1800 AIIOnline explosion-proof trace oxygen analyzer
Technical Specifications:
Range: 0~10/100/1000ppm, 1%/25% automatic or manual adjustment.
Sensor: Galvanic Fuel Cell - GPR-12-333 or GPR-12-100-M
Galvanic Acid Battery - XLT-12-333 or XLT-12-100-M
Accuracy: 1% of the measuring range (at room temperature and atmospheric pressure).
Measurement resolution: 0.5% of the range (minimum 50ppb).
Sensor lifespan: 24 months (at 1000ppm)
Linearity: R-squared>0.995
Calibration gas: It is recommended to use 8-9ppm O2 in N2 standard gas
Response time: 10 seconds to reach 90%
Response time: 60 minutes from air (60 seconds) to 10ppm

Operating conditions:
Application areas: hydrogen/nitrogen/CO2 equipment, purification/drying equipment, etc
Measurement media: H2, He, CO2, hydrocarbons, inert gases, etc
Interface: The inlet and outlet use 1/8 "card sleeve connectors
Pressure: 5-30psig
Temperature: 5~+45 ℃ (GPR sensor), -20~+45 ℃ (XLT sensor)
Flow rate: 0.5~5 SCFH, recommended: 2 SCFH (cubic feet per hour)
Electrical features:
Certification: ISO9001, CE certification.
Display: Large screen LCD display, capable of real-time display of sample gas pressure and temperature.
Display resolution: 0.1% of the current range (minimum: 0.01ppm)
Control button: Waterproof button, easy to select range, calibration, etc..
Explosion proof: intrinsically safe design, with isolation barriers can be used in hazardous areas: Class 1, Division 1, Groups B, C, D
Compensation: Automatic pressure and temperature compensation function.
Output: Two wire 4-20mA analog output; Optional alarm function
Power supply: 9-28 V DC (24-28 V DC with isolation barrier).
Physical characteristics:
Encapsulation: Made of alumina material, NEMA 4X, wall-mounted design
ATEX standard EX d [ib] ib IIB T4 is used for installation in explosion-proof areas. Power supply 12-24VDC or 100/230VAC, 4-20mA signal output. Two on-site alarm program time relays and relay nodes.
The unique advanced current oxygen sensor is capable of analyzing oxygen levels below 100ppb. It has automatic adjustment conversion, zero adjustment, calibration, and system self diagnostic functions. NEMA 4 rack mounted installation is optional The diagram shows the H2S sampling system.
Range: - Standard: 0-10 ppm, 0-100 ppm, 0-10pm, 0-1%, 0-25%