GENTEC-EO Power Detector XLP Series

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Product Name: GENTEC-EO Power Detector XLP Series $r $n $r $n Product Model: XLP12-3S-H2-D0 $r $n $r $n $r $n Product Introduction: The Gentec EO UP power detector series includes various photothermal sensors, equipped with different absorbers, aperture sizes, and cooling options. These detectors are designed to provide reliable measurements and high damage thresholds. Each detector is calibrated using traceable and certified methods to ensure high accuracy.

Product Details

Product Name: GENTEC-EO Power Detector XLP Series

Product Model: XLP12-3S-H2-D0

Product Introduction The Gentec EO UP power detector series includes a variety of photothermal sensors, equipped with different absorbers, aperture sizes, and cooling options. These detectors are designed to provide reliable measurements and high damage thresholds. Each detector is calibrated using traceable and certified methods to ensure high accuracy. The UP type detector comes standard with a 180cm flexible cable and offers two output connection options: an intelligent DB15 male interface or an Integra instrument interface (USB/RS232). The wireless (BLU) model does not come with a connecting cable. Can customize cables of different lengths or replace interface types (such as BNC, Molex, or BNC/Molex combination interfaces). If your display screen or measuring instrument cannot automatically read the wavelength correction factor, you can use the detector's "personal wavelength correction certificate" to adjust the read power value to the corrected power value at a specific wavelength.

Performance characteristics:

The uncertainty of laser calibration wavelength has now been reduced to only± 2.0 %

Low power thermoelectric stack

Thermal drift only6 µ W/° C (with infrared filter)

high sensitivity

Ultra short pulse special model

Remove harmful infrared interference

Removing power fluctuations caused by air turbulence

Selection Guide:

XLP12-3S-H2-D0 201032

XLP12-3S-H2-INT-D0 202609: USB output type

XLP12-3S-H2-BLU-D0 203544: Wireless (air) without meter

XLP12-3S-H2-IDR-D0 203391: RS-322 output type

Product structure and details:

XLP series laser power detector

protective shield

Calibration Certificate

Personal wavelength calibration certificate

Power supply and national AC power cord (applicable only to air-cooled detectors):FAN-12V; UPG-12V

beltIsolation pipe with SM1 thread: XLP12-TUBE number: 101449

Optional features and accessories:

supportSTAND-S-233:200160

supportSTAND-S-443:200234

supportSTAND-S-443-C:201102

fiber optic adapter

extension cord

Technical Specifications:

Origin: Canada

Part number:201032

Max average power (continuous): 3 W

Max average power (1 minute): 3 W

Noise equivalent power:0.5 μW

Spectral range:0.193 to 20 μ m

Typical rise time:2.5 s

Power calibration uncertainty:±2 %

Repeatability:± 0.5 %

Thermal drift:12 μW/°C

Max measurable energy: 5 J

Equivalent energy of noise:12 μJ

Min repetition cycle: 16 seconds

Max pulse width: 300 ms

Energy calibration uncertainty:± 5 %

Max average power density: 1 kW/cm ²

Max energy density: 1 J/cm ²

Cooling method: convective cooling

Aperture diameter:12 mm

Absorbent:H₂

Size(H × W × D): 73 x 73 x 20 mm (including pipe diameter of 72 mm)

Weight:0.31 kg

Place of Origin

Canada

Part Number

201032

Max average power (continuous)

3 W

Max average power (1 minute)

3 W

Equivalent power of noise

0.5 μW

spectral range

0.193 to 20 μ m

Typical rise time

2.5 s

Power calibration uncertainty

±2 %

repetitiveness

± 0.5 %

thermal drift

12 μW/°C

Max measurable energy

5 J

Equivalent energy of noise

12 μJ

Min Repetitive Cycle

16 s

Max pulse width

300 ms

Energy calibration uncertainty

± 5 %

Max average power density

1 kW/cm²

Max energy density

1 J/cm²

cooling method

Convective cooling

Aperture diameter

12 mm

absorbent

H₂

Size(H×W×D)

73 x 73 x 20 mm (including pipe diameter of 72 mm)

weight

0.31 kg

Product application:

Research, electronics, automotive, aerospace, remote sensing, telecommunications