GB/T8929-88-2006 Standard for Use of Microcomputer LCD Display Control Type Fully Automatic Crude Oil Moisture Determination Instrument

NegotiableUpdate on 03/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The microcomputer LCD display control type fully automatic crude oil water content measuring instrument relies on high-temperature steam flow to increase the temperature of crude oil, so that the temperature of water in the oil reaches over 100 degrees, turning it into steam and magnetizing it, allowing the iron substances in the oil to rotate at high speed, quickly separating the emulsified water and evaporating the water vapor in the oil, achieving the purpose of rapid measurement. Therefore, the diluent added should not exceed 150 grams (sample 200 grams), otherwise a large amount of light group gas will quickly enter the cooling tube. Once it encounters the gas sensing probe above, the instrument will automatically stop heating and enter a cooling state, which cannot achieve the rapid effect.
Product Details

Microcomputer LCD display control type fully automatic crude oil water content measuring instrumentIt relies on high-temperature steam flow to increase the temperature of crude oil, making the temperature of water in the oil reach over 100 degrees, turning it into steam and magnetizing it, allowing the iron substances in the oil to rotate at high speed in the oil, quickly separating the emulsified water and evaporating the water vapor in the oil, achieving the purpose of rapid measurement. Therefore, the diluent added should not exceed 150 grams (sample 200 grams), otherwise a large amount of light group gases will quickly enter the cooling tube. Once it encounters the gas sensing probe above, the instrument will automatically stop heating and enter a cooling state, which cannot achieve the rapid effect.

HZXJ-T6B (desktop) microcomputer LCD display control type fully automatic crude oil water content analyzer

Microcomputer LCD display control type fully automatic crude oil water content measuring instrumentIntroduction:

The microcontroller program controls the instrument to complete the entire experimental steps, using a backlit LCD display screen. Through the program, the temperature can be controlled with wide range and high precision, so that the oil can reach a certain temperature and automatically cool down, eliminating the hidden dangers caused by excessive temperature and sudden boiling of the oil. Microprocessing technology uses liquid crystal displays to better control and monitor the working status of instruments. It is a micro controlled HZXJ-T6 (desktop) analyzer developed by our unit, which is a reliable instrument for laboratories, oil production plants, gathering and transportation stations, scientific research units, and various oil post laboratories. itsPerformance characteristics:

1. The whole machine is integrated to complete the entire testing process.

2. Adopting a backlit large screen LCD display.

3. Equipped with micro memory function.

4. The HZXJ-T6 (desktop) model is functionally independent.

5. Measurement accuracy ≥ 100%.

6. Measurement time: 10-15 minutes.

7. Six separate controls.

8. Achieve the operation mode of "start guard free".

9. There is a micro control anti-counterfeiting mark.

Microcomputer LCD display control type fully automatic crude oil water content measuring instrumentWorking Principle:

This instrument can simultaneously test six samples. When the number of samples is less than six, the HZXJ-T6 (desktop) sample can be freely selected and used immediately, as each sample hole is an independent micro control device. The optimal temperature required for the experiment can be reached by default at 50 ℃. When the temperature reaches the default temperature, the heating system will automatically protect, disconnect the heating, and start the fan to dissipate heat. Automatically heating below the default temperature, with the most ideal constant temperature effect. The stirring speed is set by default based on the optimal effect of magnetic emulsification, and does not require further adjustment. The HZXJ-T6 (desktop) instrument has fully automated all the necessary conditions for testing, eliminating the need for staff monitoring, increasing work efficiency, shortening testing time, and achieving a "start no guard" operation mode.

Crude oil ratio table

Due to the varying workloads of different units, the HZXJ-T6 (desktop) fully automatic LCD microcontroller with six components is equipped with the following specification table for reference.

Installation Introduction:

There is a pull-out bracket at the back of the casing, which is hollow and can hold purified water for circulation. This solves the problem of the instrument hose wrapping around the entire bracket in the past, making the overall view three-dimensional. Simply connect the HZXJ-T6 (desktop) inlet and outlet together with the hose. Achieve convenient and simple work efficiency during installation.

Microcomputer LCD display control type fully automatic crude oil water content measuring instrumentUsage:

1. Fix the bracket according to the fifth installation instructions, pour the sample oil into the glass instrument, install the glass instrument, and then connect the inlet and outlet of the condenser pipe to the bracket water nozzle with a hose

2. Insert the power into the power socket, and the purified water cooler will start cooling.

model

Specifications

sampling quantity

Dilution amount

voltage

Measurement time min

Quantity of samples tested

accuracy

HZXJ

1000mL×2

200 grams

100 grams

220V

10-15

2

100%

HZXJ

1000mL×4

200 grams

100 grams

220V

10-15

4

100%

HZXJ

1000mL×6

200 grams

100 grams

220V

10-15

6

100%

HZXJ

1000mL×12

200 grams

100 grams

220V

10-15

12

100%

3. The LCD screen displays the "Snow" cooling symbol, indicating that the instrument is in working condition.

4. The LCD screen displays symbols 1.2.3.4.5.6 indicating the number of holes, and the "eleven" key is the hole selection key.

5. If you press the "+-" key, the hole number key "1" will jump, and then press the start key, the hole number "1" will enter the heating, stirring, and circulating water working state.

7. Press the "stop" button to indicate the status of stopping the number of holes. When the sample is different and the hole number test is completed, press the "stop" button to stop the work and enter the restoration state.

8. After the experiment is completed, it will automatically cool down and enter standby mode.

Microcomputer LCD display control type fully automatic crude oil water content measuring instrumentNotes:

1. Before use, it is necessary to read the instructions and operate according to the instructions. It is not allowed to open or ask other manufacturers for repairs without authorization, otherwise our factory will not be responsible.

2. There is white smoke and odor during repeated use, which is a normal phenomenon.

3. Due to the difference from the old distillation method, the cooling water flow rate is increased, and it is strictly prohibited to change the gasoline dilution ratio of the new distillation method.

4. This instrument is for rapid distillation and cannot use a 30cm fine mouth (12 # mouth) condenser. A moisture analyzer with a diameter of 19 # or above must be used.

5. When the backlight LCD display light does not light up or its keys malfunction, please immediately turn off the power and stop working.

6. The heating core should avoid spilling solution, which may cause electrical leakage.

7. The casing should be kept clean to increase usage time.

After-sales service

1. If the instrument accessories are damaged, please replace them with specialized accessories from the manufacturer and continue to use them. The instrument comes with a free one-year warranty.