Fully automatic multi parameter flow injection analyzer iFIA7

NegotiableUpdate on 10/08
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Fully automatic multi parameter flow injection analyzer iFIA7

Product Details

Product Overview of iFIA7 Fully Automatic Multi Parameter Flow Injection Analyzer
Your intelligent manager for chemical analysis
The all-new iFIA7 fully automatic multi parameter flow injection analyzer utilizes the principle of flow injection (FIA) to determine components such as cyanide, volatile phenols, anionic surfactants, sulfides, total phosphorus, total nitrogen, hexavalent chromium, borides, etc. in water and seawater, soil, food, and plant extracts. We are committed to providing customers with comprehensive, fast, accurate, and safe project detection solutions, ushering chemical analysis into the era of intelligence. Gold Award winning product in the instrument industry (awarded BCEIA 2017 Gold Award), with integrated instrument design and support for multi parameter simultaneous testing, bringing intelligent transformation to your laboratory.
Jitian Instrument iFIA7 Fully Automatic Multi Parameter Flow Injection Analyzer Product Features
Stable liquid inlet system, adaptive optics system is more stable and accurate
Stable liquid inlet system
The pressure adjustable peristaltic pump adopts a new elastic material that can adapt to different wall thicknesses of pump tubes, solving the problem of inconsistent fatigue trends of traditional pressure covered peristaltic pumps due to different wall thicknesses of pump tubes
Adaptive optics system
The adaptive optical path adjustment system can automatically adjust the detection wavelength and gain adjustment of the light intensity according to the detection method, intelligently realizing wavelength switching, gain adjustment, and multi path adaptive, providing better optical performance and making the detection results accurate and reliable
Support multiple specifications of flow detection pools (10-30mm configurable optical path), expandable to different types of detectors such as UV and electrode, to meet different detection needs
Humanized software design for intelligent flow control system is more trustworthy
Intelligent flow control system
Integration of multifunctional detection methods, automatic switching and preheating of different detection methods, automatic cleaning program added during method switching to avoid cross contamination of different detection items and improve detection accuracy
The newly developed MAC analysis module allows one device to achieve 3-17 detection methods (ammonia nitrogen, nitrate, nitrite, orthophosphate, silicate, boron, total hardness, total alkalinity, iron ions, calcium ions, hexavalent chromium, offline sulfides, aluminum ions, offline total Kjeldahl nitrogen, offline total Kjeldahl phosphorus, etc.)
Humanized software design
The software has implemented a visual full state monitoring function, ensuring consistency and repeatability of detection conditions, and keeping the instrument in the most suitable state at all times
Multiple standard method files are built-in in the software, which can provide corresponding application solutions for different industries and be competent for your multi type sample analysis tasks
Multiple automatic samplers can be configured
Three dimensional/polar coordinate automatic sampler, capable of upgrading functions such as automatic recognition of sample disk specifications, tracking detection of injection needle liquid level, anti puncture bias protection, and detection of cleaning solution liquid level
Jitian Instrument iFIA7 Fully Automatic Multi Parameter Flow Injection Analyzer Application Fields
Water quality testing solution
Fully comply with national/industry standard methods
GB 8538-2016 Method for Testing Cyanide in Natural Mineral Water for Drinking Water in the People's Republic of China
GB 8538-2016 Method for Testing Volatile Phenols in Natural Mineral Water for Drinking Water in the People's Republic of China by Flow Injection Method
Water quality - Determination of ammonia nitrogen - Flow injection salicylic acid spectrophotometric method HJ 666-2013
Determination of Total Nitrogen in Water Quality - Flow Injection Naphthalene Ethylenediamine Hydrochloride Spectrometric Method HJ 668-2013
Determination of total phosphorus in water quality - Flow injection ammonium molybdate spectrophotometric method HJ 671-2013
Determination of volatile phenols in water quality - Flow injection 4-aminoantipyrine spectrophotometric method (HJ 825-2017)
Water quality - Determination of sulfides - Flow injection methylene blue spectrophotometric method HJ 824-2017
Determination of cyanide in water quality by flow injection spectrophotometry HJ 823-2017
Water quality - Determination of anionic surfactants - Flow injection methylene blue spectrophotometric method (HJ 826-2017)
More detection solutions for various industries
1. Soil/plant extract detection: nitrate, nitrite, ammonia nitrogen, phosphate, silicate, sulfate, etc
2. Food/grain testing: amylose, total sugar/reducing sugar, calcium, formaldehyde, cyanide, etc
3 Feed/fertilizer testing: Kjeldahl nitrogen, nitrate nitrogen, phosphate, urea, ammonia nitrogen, total nitrogen, calcium, etc
Technical performance indicators of Jitian Instrument iFIA7 fully automatic multi parameter flow injection analyzer

Specifications Technical Specifications
Liquid inlet system Adjustable pressure peristaltic pump
Pump speed: 0-100r/min continuously adjustable
Optical system performance detection wavelength 340-1100nm
Dual beam detection
Noise: < 0.0001Au
Drift: < 0.001Au
100% transmittance performance
Whole machine testing performance detection limit ~ug/L
precision RSD<1.0%
stability RSD<3%(@4Hr)
Linear dynamic range >103
Multi channel simultaneous testing Standard computer configuration
(4GB memory)
8-16 devices (including automatic sampler)
Running simultaneously
Higher configuration Theoretical support for 254 devices running simultaneously
Overall dimensions (mm) single unit
Depth x Width x Height
780mm x 270mm x 300mm
Total weight single unit 30Kg
Power requirements single unit 220V/50HZ
Total power consumption single unit Start preheating: 600W
Stable operation: 400W