If you encounter poor stability of manually operated batches and unreliable experimental data when fermenting items such as Pichia pastoris, Escherichia coli, and Bacillus subtilis; The process of process development cannot be automated, resulting in high labor costs; Not practicing using different brands of equipment; When dealing with issues such as poor stability in fermentation process control, you can try this reactor. Integrate the fermentation process into the control system based on the principles of different bacterial strains. We have launched a reactor that is different from those on the market: the FKE-A5 reactor. On the basis of retaining the traditional reactor functions, this reactor has added fermentation logic control for Escherichia coli, Pichia pastoris, and Bacillus subtilis, achieving true fully automatic fermentation. It can be used for rapid screening of strains, culture media, and control parameters.

Product Features:
1. Support expansion, after expansion, the single tank system will automatically upgrade to a multi parallel system.
2. Fully automatic fermentation does not require process control and can be used for rapid parameter screening and deep optimization of screened parameters.
3. Good mass transfer and dissolved oxygen conditions, making it difficult for zero to fall off,
4. Remote operation through mobile app and computer, sending device alarm information via SMS.
| project name | scope of control | control deviation | resolution |
|---|---|---|---|
| stir | 0-1200 rpm/min | ±2 rpm/min | 1 rpm |
| air | 0-10 L/min | ±0.1 L/min | 0.01 L/min |
| oxygen | 0-5 L/min | ±0.1 L/min | 0.01 L/min |
| pH | 0-14 | ±0.05 | 0.01 |
| DO | 0-200 | ±3 | 0.01 |
| temperature | 5-60℃ | ±0.1℃ | 0.1℃ |
| glucose | 0-5 g/L | 0-50% | 0.1 g/L |
| glycerol | 0-5 g/L | 0-50% | 0.1 g/L |
| Four way replenishment | 1-4000 ml/h | ±0.5% | 0.1 ml/h |
| project name | content | remark |
|---|---|---|
| Sterilization size | 248×248×570 | A sterilization pot of 50L or more is required |
| stirring paddle | Two layers of straight bladed propellers, one layer of inclined bladed propellers | |
| total volume | 5L | Other specifications can be customized |
| Light to height ratio | 1.2.2 | |
| working volume | 1-3.5L | |
| Mixing form | mechanical stirring | |
| Temperature control form | Hollow baffle+heating blanket | |
| seal | Single end mechanical seal | |
| Control method | 15-inch touchscreen |