Overview

Thermocouples and thermal resistors are fully automatic calibration devices used by temperature measurement departments and temperature laboratories to calibrate various types of thermocouples and thermal resistors. The fully automatic calibration device for thermocouples and thermal resistors is fully automated by computer control, including temperature control of the calibration furnace, collection of detection signals, compensation of thermocouple cold end temperature, correction and processing of data, printing of calibration records, and issuance of calibration certificates. The fully automatic calibration device for thermocouples and thermal resistors can store calibration records and results on a hard drive for easy access, printing, and retrieval at any time. The fully automatic calibration device for thermocouples and thermal resistors is easy to operate, and the operation window and printing are all localized in Chinese. The screen displays parameters such as furnace temperature curve, furnace temperature, heating rate, and set temperature, making the entire process intuitive and clear. The software of the fully automatic calibration device for thermocouples and thermal resistors is fully designed according to ITS-90 and meets the requirements of the national metrological calibration regulations.

Product Details

Fully automatic calibration device for thermocouples and thermal resistors
Fully automatic calibration device for thermocouples and thermal resistorsIt is an automated calibration device used by the temperature measurement department to calibrate all scale industrial thermocouples and industrial resistance thermometers. (Fully automatic calibration device for thermocouples and thermal resistorsWJZ3The thermocouple and thermal resistance automatic calibration device can also be used for the metrological calibration of standard thermocouples. The entire process of temperature control of the calibration furnace, collection of detection signals, compensation of thermocouple cold end temperature, correction and processing of data, printing of calibration records, and issuance of calibration certificates is fully automated by computer control.The fully automatic calibration device for thermocouples and thermal resistors can achieveThe verification records and results are stored on the hard drive for easy access, printing, and retrieval at any time. The fully automatic calibration device for thermocouples and thermal resistors is easy to operate, and the operation window and printing are all localized in Chinese. The screen displays parameters such as furnace temperature curve, furnace temperature, heating rate, and set temperature, and the entire process is intuitive and clear. The software is fully compliant withITS90The design fully complies with the requirements of the national metrological verification regulations. The fully automatic calibration device for thermocouples and thermal resistors has the characteristics of high detection accuracy, good reliability, easy operation, and full automation. It is an upgraded product for the calibration of thermocouples and thermal resistors in China's metrology department.

The fully automatic calibration device for thermocouples and thermal resistors consists of two parts: hardware and software. The hardware is controlled by the main control cabinet12Channel junction boxes, cables, and currently popular microcomputer systems in the marketHPComposed of laser printers and other components. The software has all application programs for verifying industrial thermocouples and thermal resistors,WINRun it down, with a full graphical interface.

Main technical characteristics of the fully automatic calibration device for thermocouples and thermal resistors:

(1) The fully automatic calibration device for thermocouples and thermal resistors can be used for calibrationThe division number is:BSRKJTEEU-2EA-2Industrial thermocouples.

(2) The division number is:Pt100Pt10Pt500Pt1000Cu50Cu100GIndustrial thermistor.

(3) The fully automatic calibration device for thermocouples and thermal resistors can be used for calibrationVerification temperature:-200-1550At any temperature point (determined by the calibration furnace and constant temperature bath).
Fully automatic calibration device for thermocouples and thermal resistors
Control furnace temperature stability: The variation of the thermal resistance calibration furnace shall not exceed
0.05/15minThe variation of thermocouple calibration furnace shall not exceed0.2/15min.