-
E-mail
jttjyq@163.com
-
Phone
13585400372
-
Address
No. 22 Hongshan Road, Jincheng Industrial Park, Jintan City, Jiangsu Province
Changzhou Tianjing Experimental Instrument Factory
jttjyq@163.com
13585400372
No. 22 Hongshan Road, Jincheng Industrial Park, Jintan City, Jiangsu Province
| SHZ-82Freezing water bath constant temperature oscillatorIntroduction: SHZ-82Freezing water bath constant temperature oscillatoralso calledWater bath constant temperature shaker, is a biochemical instrument that combines a temperature controlled constant temperature water bath and oscillator. This series of products adopts a microcomputer temperature control system, with high temperature control accuracy, convenient temperature adjustment, accurate and intuitive display values, and reliable performance. The water bath constant temperature oscillator has some characteristics such as reasonable structure, easy operation, and high stability, making it an ideal equipment for laboratory workers to handle with ease. It is mainly suitable for constant temperature oscillation cultivation of various liquid and solid compounds such as biology, biochemistry, cells, and bacterial strains in scientific research departments such as universities, oil and chemical engineering, health and epidemic prevention, and environmental monitoring. Introduction to three working modes of water bath constant temperature oscillator: 1. Cyclotron oscillation: This working method is also called circular oscillation, which rotates 360 ° on the horizontal plane. For example, when working in this way, the liquid being oscillated presents a vortex state in the container to achieve a uniform effect. 2. Reciprocating oscillation: As the name suggests, it means oscillating back and forth during oscillation, using inertia to oscillate the sample. Why use this oscillation method? Because when the viscosity of the liquid is high, this oscillation method works much better than cyclotron oscillation. 3. Dual function oscillation: It combines two modes of oscillation: cyclotron and reciprocating oscillation. Introduction to three working modes of water bath constant temperature oscillator: 1. Cyclotron oscillation: This working method is also called circular oscillation, which rotates 360 ° on the horizontal plane. For example, when working in this way, the liquid being oscillated presents a vortex state in the container to achieve a uniform effect. 2. Reciprocating oscillation: As the name suggests, it means oscillating back and forth during oscillation, using inertia to oscillate the sample. Why use this oscillation method? Because when the viscosity of the liquid is high, this oscillation method works much better than cyclotron oscillation. 3. Dual function oscillation: It combines two modes of oscillation: cyclotron and reciprocating oscillation. Depending on the characteristics and working requirements of the sample, one can choose any working method at their own discretion. Considerations for selecting a water bath constant temperature oscillator: 1. Choosing a suitable temperature control range, the temperature control range of an experimental equipment, plays a crucial role in the success or failure of the experiment. Therefore, the appropriate temperature control range can be selected according to the requirements of the experiment. If you feel that the selection process is quite cumbersome, you can buy an instrument with a slightly larger temperature control range. 2. By selecting the appropriate temperature control precision for the product, the constant temperature conditions of the experiment are controlled quite accurately, reducing almost all environmental factors caused by temperature fluctuations to zero. 3. Determining whether the manufacturer is an instrument agent or a manufacturer will directly affect the speed and effectiveness of resolving after-sales issues with the water bath constant temperature oscillator product. SHZ-82 Cryogenic Water Bath Constant Temperature OscillatorTechnical Specifications:
SHZ-82Features: 1. Temperature control range: room temperature -100 degrees. 2. Temperature control method: Adopting microcomputer temperature control, precise temperature control, no overheating or overshoot phenomenon. 3. Oscillation mode: spiral. 4. Inner liner material: high-quality stainless steel, universal spring clamp, and different clamps can also be designed according to requirements. 5. Shell material: High quality cold plate surface with electrostatic spraying, rust prevention, and extended service life. 6. Motor type: Permanent magnet DC motor, small size, high power, long service life, and also has the characteristics of low noise. 7. Speed regulation method: stepless speed regulation. 8. Timing range: 0-9999 minutes or normally open. Note: After each use, attention should be paid to cleaning in a timely manner to extend the service life. SHZ-82 1. Please read this manual carefully before use. SHZ-82Instructions for Use: 1. Add an appropriate amount of water to the water tank (the water level should be 2-3cm above the spring clamp) and place the reagent bottle on the spring clamp. 2. Firstly, turn on the power, turn on the heating switch, and the temperature controller will light up. At this time, click the SET function button on the temperature controller. Click the set function button on the temperature controller, and the upper row will display sp and the lower row will display the set temperature. Click the △ or ▽ button to select the desired working temperature. After setting, click the set function button again to enter the constant temperature timing setting. The upper row will display st and the lower row will display the set time. Click the ▲ or ▼ button to select the constant temperature timing time. (If no timing is required, set the time to 0) Click the set button again to exit the setting state. At this time, the temperature inside the box is running at a constant temperature according to the set temperature; After running, the buzzer will sound an alarm and stop heating. 3. Adjust the oscillation 'timing knob', select the oscillation timing time (if timing is not required, adjust the timing knob to the normally open position), and then slowly adjust the 'speed control knob' to the desired oscillation speed. 4. After use, adjust the speed control knob to the 0 position, turn off the power. If not in use for a long time, unplug the power, drain the water, clean and wipe it clean in a timely manner to extend its service life. SHZ-82Precautions 1. The power socket provided by the user should have good grounding measures. |