float level gauge
Product Code: 89216016
Product Name: UHZ Float Level Gauge
Specifications:
Product Remarks:
Product Category: Level Gauge
UHZ
The UHZ series is an instrument used for liquid level detection, display, and transmission. The instrument has a maximum range of 20M and a measurement accuracy of 0.03% FS
The UHZ series is a two-wire instrument that provides a five digit LCD display on site and also offers 4-20mADC remote transmission signals. The UHZ-IIHHART instrument is an intelligent instrument that complies with the HART protocol. The transmitter directly outputs 4-20mADC analog and digital signals that comply with the HART protocol
◆Main technical indicators
Range: 10M, 20M
Display: Five digit display (LCD), unit: MM
HART type without on-site display
Accuracy: ± 0.03% FS ± 1 number
Analog output: 4-20mADC two-wire system
Transmission accuracy: ± 0.5% FS, ± 0.2% FS (HART type)
Load resistance: 0-430 Ω
Power supply: UHZ-113 24VDC ± 10%
Power supply not less than 30mA
Environmental temperature: -25~60 ℃
Density of the tested medium: not less than 0.7g/cm3
Float size: 200X400X50 (MM)
Float weight: 1550g (rectangular box)
Measurement strip and directional mechanism material: Stainless steel 1CR18NI9TI
Installation form: Sensor, flange installation, flange diameter not less than ¢ 260
Display transmitter: wall mounted or column mounted
Work pressure: 2.5MPA at normal pressure
Explosion proof mark: Explosion proof type: DIIBT6 Intrinsic safety type: IAIICT5
Outgoing nut: M20 * 1.5
◆ Structural principle
The UHZ series consists of sensors and display transmitters.
The sensor is installed on the tank, and a measuring steel strip extends from the bottom of the sensor. A float is suspended at the end of the steel strip. When the float changes within the full range, the tension of the steel strip on the float remains basically unchanged (the tension becomes less than 0.5 Newton). The self weight of the float is greater than the tension of the steel strip, and the float is partially immersed in the liquid. Due to the constant tension, the depth of immersion of the float into the liquid remains unchanged. Therefore, it can be assumed that the float moves strictly synchronously with the liquid level. After deducting a fixed initial value, the position of the float represents the liquid level.
model |
|
|
|
|
|
Explanation |
UHZ - 11 |
|
|
|
|
|
Float type liquid level gauge |
|
3 |
|
|
|
|
Indicating with transmission and output of 4-20mA |
|
H |
|
|
|
|
4-20mA and digital quantity compliant with HART protocol |
|
|
10 |
|
|
|
10M |
|
|
20 |
|
|
|
20M |
|
|
|
A |
|
|
Addition count (displaying liquid level height) |
|
|
|
B |
|
|
Subtraction counting (displaying the distance from the top of the tank to the liquid level) |
|
|
|
C |
|
|
HART |
|
|
|
|
1 |
|
atmospheric pressure |
|
|
|
|
2 |
|
2.5MPA |
|
|
|
|
|
|
non-explosion-proof |
|
|
|
|
|
DIIBT6 |
flameproof |
|
|
|
|
|
IAIICT5 |
intrinsically safe |
◆Installation and usage precautions
The user needs to open a hole at a suitable position on the top of the tank and weld a flange for installation. The flange size is shown in the figure, and the flatness error of the flange should not exceed 3. The opening position should be the position where the liquid flow in the tank is weakest, and there should be no obstacles within a diameter range of ¢ 500 directly below the opening position that hinder the float from moving up and down.
The user needs to make a reducing flange for connecting instrument sensors and installing the flange. The small end of the reducing flange is connected to the flange of the sensor, and the large end of the reducing flange is connected to the installation flange. The size of the reducing flange is shown in the figure