Flange type liquid level transmitter -3151LT

NegotiableUpdate on 12/01
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Flange type liquid level transmitter -3151LT

Product Details

  • The 3151LT flange type liquid level transmitter is a newly launched small intelligent transmitter that introduces advanced digital circuits and communication technology. It is suitable for measuring flow, liquid level, and pressure (differential pressure, gauge pressure, and absolute pressure). Compared with traditional transmitters, the 3151 smart transmitter reduces weight by one-third, improves overall performance, and offers precision levels of 0.075, 0.1, and 0.2 for users to choose from. It is an ideal measuring instrument for fields such as petroleum, chemical, metallurgy, power plants, light industry, and municipal engineering. The 3151 series intelligent transmitter adopts the HART communication protocol and supports technology upgrades to fieldbus.
    The measured pressure is converted into a capacitive variable by a capacitive sensitive element, and then directly converted into a digital signal through a C/D circuit before being sent to a microprocessor. The digital signal corrected by operation is then converted into a 4-20mADC output signal through D/A conversion and sent to display/regulating instruments or DCS devices. The communication line converts the measured pressure digital signal from the microprocessor into a frequency signal and superimposes it on a 4-20mADC analog signal, which is received by the corresponding HART terminal device. Excellent characteristics and performance; Strong adaptability; High reliability; High precision; Large range adjustment ratio; Self diagnostic function; Long term drift is small; HART digital communication; Overpressure self-protection; Low temperature impact; Remote/on-site calibration; Low static pressure impact


  • Parameters and specifications:
  • Main technical indicators
    Measurement range for medium liquids, gases, or vapors
    Range adjustment ratio 100:1
    Accuracy within ± 0.075% of the adjusted range
    ± 0.1% of maximum range
    Output a two-wire 4-20ADC (optional linear or square root output) and superimpose process variable digital signals that comply with the HART protocol. Power supply voltage 12.5~48VDC
    Environmental temperature -40~85 ℃
    Measure medium temperature -40~104 ℃
    Weight 3.9kg (excluding options)
    Selection method

    3151LT type
    Flange mounted liquid level transmitter
    code name
    measurement range
    4
    0-0.40~40kPa
    5
    0-2~200kPa
    6
    0-7~700kPa
    code name
    output signal
    A
    4-20mA digital signal with HART protocol
    code name
    size
    Insertion tube length
    High voltage side isolation diaphragm and insertion tube material
    A0
    A2
    A4
    A6
    B0
    B2
    B4
    B6
    C0
    C2
    C4
    C6
    D0
    D2
    D4
    D6
    E0
    F0
    3#
    3#
    3#
    3#
    4#
    4#
    4#
    4#
    3#
    3#
    3#
    3#
    4#
    4#
    4#
    4#
    3#
    4#
    flat
    50.8mm
    101.6mm
    152.4mm
    flat
    50.8mm
    101.6mm
    152.4mm
    flat
    50.8mm
    101.6mm
    152.4mm
    flat
    50.8mm
    101.6mm
    152.4mm
    flat
    flat
    316SST stainless steel
    316SST stainless steel
    316SST stainless steel
    316SST stainless steel
    316SST stainless steel
    316SST stainless steel
    316SST stainless steel
    316SST stainless steel
    Hastelloy C
    Hastelloy C
    Hastelloy C
    Hastelloy C
    Hastelloy C
    Hastelloy C
    Hastelloy C
    Hastelloy C
    Tantalum
    Tantalum
    code name
    Install flange
    A
    B
    C
    D
    3 #, 150, used in conjunction with the above A and C codes, carbon steel
    4 #, 150, used in conjunction with the above A and C codes, carbon steel
    3 #, 300, used in conjunction with the above A and C codes, carbon steel
    4 #, 300, used in conjunction with the above A and C codes, carbon steel
    code name
    Structural materials for sensor components and low-voltage side
    Low pressure side pressure chamber and joint
    relief valve
    Low voltage side isolation membrane
    Low pressure side filling fluid
    12
    22
    23
    25
    316SST stainless steel
    316SST stainless steel
    316SST stainless steel
    316SST stainless steel
    316SST stainless steel
    316SST stainless steel
    316SST stainless steel
    Hastelloy C
    Tantalum
    silicone oil
    2A
    2B
    2D
    316SST stainless steel
    316SST stainless steel
    316SST stainless steel
    316SST stainless steel
    316SST stainless steel
    316SST stainless steel
    316SST stainless steel
    Hastelloy C
    Tantalum
    Inert oil
    code name
    High pressure side liquid flange filling fluid
    C
    D
    H
    DC704 silicone oil
    DC200 silicone oil
    Inert oil
    code name
    Optional items
    M11
    Linear indication (engineering unit or 100%)
    3151LT   4    A    AO   A   22     C   M11   Complete model of transmitter