Fixed respiratory air quality analyzer
Continuous measurement of respiratory air quality:
For breathing air, human health and safety are of paramount importance. Due to breathingAir pollution has even caused fatal accidents in the past. To ensure the provision ofThe highest safety of breathing air requires an online measurement system.Traditional respiratory air analysis involves collecting samples and then conducting them in an external laboratoryConduct analysis. Online systems are rarely available and often come with very high costsInvestment and extensive process modifications.SUTO has changed this approach. The S606 respiratory air quality analyzer will be the most advancedNew sensor technology combined into a plug and play measurement solution.S606 Continuous Measurement of Breathing Air Quality StandardO2TheCO2TheCO、Dew point, oil mist, particulate matter, and pressure, and when the measured values are not within the specified rangeNotify users promptly.It is smarter, faster, and more convenient than traditional methods.
Advantages:
Multi in one device, simultaneously measuring O2, CO2 in respiratory gases
CO、 Dew point, oil mist, and particulate matter
Continuous breathing air measurement with programmable alarm configuration
Testing respiratory air quality according to national and international standards
Connect compressed air through a 6mm pipe
All parameter measurements require only one sampling point
The integrated data logger stores data for future analysis.
Application:
S606 is a compact wall mounted breathing air system
Quantitative analyzer, capable of measuring all critical breathing air
Parameters to ensure the safety of breathing air for health and process safety.
Key industries and sectors rely on reliable breathing air
Supply, such as firefighting, diving, spraying, chemical engineering
Marine engineering and high-tech applications.
7-in-1 measuring equipment:
O2 oxygen measurement
Optical oxygen sensor detects oxygen content and indicates the standard concentration
Deviation.
CO2 measurement
The gas sucked in by the compressor may be exposed to high concentrations of dioxide
In carbon. The filter material used for compressed air can adsorb or
Release carbon dioxide. NDIR sensors can measure carbon dioxide from
And avoid exceeding 1000ppmcomply withConcentration
CO carbon monoxide measurement
Due to nearby internal combustion engines or heating systems, the intake of the compressor may be affected
Carbon monoxide pollution. Carbon monoxide is a toxic and life-threatening substance
Gas is accurately measured by electrochemical sensors.
H2O Dew Point Measurement
High humidity can cause corrosion, and in severe cases, it can lead to storage
Gas cylinders and other equipment burst. In cold environments, it freezes and blocks
Air supply. Integrated dew point sensor for inspecting dryers
The normal dehumidification function of the filter is crucial.
OIL oil mist and particulate matter measurement
The atmospheric oil mist and particulate matter contained in the industrial air environment can pass through
The compressor inlet enters the system. Compressed into breathing air
Oil mist and particulate pollutants can cause health problems. Advanced sensors
The device technology can immediately detect oil mist and particulate pollutants.
pressure measurement
The pressure sensor adopts advanced sensor technology to provide information about pressure
Pressure data of the compressed air system.
Integrated data logger
The integrated data logger records all channels in parallel for future use
analysis. 5-inch touchscreen allows you to interact with devices on site
Interaction, no need for PC to manage devices.
Breathing air related standards:

Why breathe air qualityIs measurement very important?
BecauseIt can protect the health and safety of employees and personnel in the workplace. Ensure that your compressors, products, and personnel are protected from the effects of volatile organic compounds (VOCs) in the air. Ensure that your enterprise complies with national and international regulatory standards for breathing air quality. Ensure that your compressed air and work environment have safe levels of oxygen, lubricants, oil mist, odors, carbon dioxide, carbon monoxide, and water.
Technical Specifications:

Order Form:
S606
Order numberDescription
D500 0606S606Touch screen interface, data logger, wall mounted metal cabinet (with oil mist and particulate matter sensors, referring to Europe)The United StatesCanadian Standards)*
D500 1606S606Touch screen interface, data logger, wall mounted metal cabinet (with oil mist and particulate gas sensors, reference to Chinese standards)*
A1670USB 4GModules, includingS4ASoftware
A554 0131USB 4GModule protection box, including 2-meter extension cable and M12 connector
A1510forS606The relay module,8Channel relay output* including:OTG type USB flash drivePurification filter for predicting quantity (test kit)1.5-meter connecting hose, one end quick connector, one end compressed air connectorM12 connectorCalibration certificate• Instruction manual