The most cost-effective two-component combustion efficiency analyzer.
Product Introduction
model:
Bluelyzer ST (simplified model: B20)Essential for measuring O2 and CO components
Application of Fiso B20 flue gas analyzer:
B20 is an ideal tool for professionals to perform precise adjustments or inspections of various small and medium-sized boilers, burners, and heating systems. It can simultaneously detect flue gas concentration, flue gas pressure, and flue gas temperature (temperature difference), and is widely used in various small and medium-sized combustion systems that use fuel and gas as fuel, such as burners, gas wall mounted boilers, gas water heaters, fuel and gas boilers, and other thermal energy equipment. The measurement standards of the instrument strictly comply with the German Federal First Emission Act BImSCHV and have passed T Ü V testing. At the same time, this multifunctional flue gas analyzer can automatically calculate important thermal parameters such as CO2, thermal efficiency, excess air value, and flue gas loss value.
Relevant parameters of B20 flue gas analyzer:
product description
The B20 smoke analyzer is a newly developed multifunctional handheld smoke analyzer with a streamlined design, compact and lightweight, weighing only 275g, making it very easy to carry. The tough protective cover integrates magnetic suction function on the back, which is dust-proof, impact resistant, and can also achieve hands-free operation, freeing up users' hands. Equipped with a 2.8-inch TFT high-definition color display screen, the measurement data is clear and easy to read. The menu and measurement items with different color codes, along with the "step-by-step guidance" measurement program, ensure maximum usability.
The B20 flue gas analyzer is equipped with the latest sensing technology and has a very short response time. It can be equipped with up to two gas sensors (O2 and CO). Optional independent MicroSD card storage system, daily measurement records can be directly generated into HTML files, and HTML file records can be viewed in a browser without the need for any other software. The instrument can also be connected to an infrared thermal printer for real-time printing of measurement records.
Technical Parameter
| range |
accuracy |
resolution |
Response time (T90) |
| O2 |
0~21.0 Vol.% |
± 0.2 vol.% measured value |
0.1 Vol.% |
﹤20s |
| CO |
0~2000/6000ppm |
±5ppm(<100ppm)
±5%Measurement value (100~2000ppm)
|
1ppm |
<30s |
|
CO2-count
|
0CO2 max
(According to the selected fuel)
|
± 0.2 vol.% measured value |
0.1 Vol.% |
﹤30s |
| flue gas temperature |
0~ +1000℃
|
±1℃(0~+300℃)
± 0.5% measurement value (>+300 ℃)
|
0.1℃
|
﹤10s |
| ambient temperature |
-20~+200℃
|
±2℃(-20 ~ 0℃)
±1℃(0.1~+200℃)
|
0.1℃
|
﹤10s |
| draft |
±40hPa |
±0.02Pa(<2 hPa)
± 1% measurement value (>2 hPa)
|
0.01hPa(<19.9 hPa)
0.1hPa(>20hPa)
|
﹤10s |
Other
Display calculated values
CO2, CO mg/m3 (gas), CO mg/kWh (fuel), combustion efficiency, flue gas loss value, excess air value, temperature difference, fuel dew point, etc
Weight approximately 275g
Dimensions (W x H x D) 67 x 37 x 144 mm
Display screen 2.8 'TFT color screen, 45 x 48 mm
Measurement interface pressure interface: Ø 7 mm
Gas interface: Ø 8 mm
Communication interface infrared, Mini-USB
Optional MicroSD card for data storage, up to 16GB
Maximum continuous operation time of 12 hours (power-saving mode)
Power supply for both AC and DC, with built-in lithium battery (3.6V/1800mAh)
Certification standards K Ü O (T Ü V ByRgG 190), DIN EN50379-2, DIN EN50379-3