Product Introduction of Fire Detector Smoke and Temperature Testing Chamber
Product Overview
Fire detector smoke and temperature testing chamberUsed for detecting smoke fire alarms, detector sensitivity, directionality, repeatability of high and low temperatures, resistance to environmental light interference, as well as temperature fire alarms, detector orientation, operating temperature, response time, and other characteristics.
meet the standard
GB 15322.1-2019 Combustible Gas Detectors Part 1: Industrial and Commercial Point Type Combustible Gas Detectors
GB 15322.2-2019 Combustible Gas Detectors Part 2: Combustible Gas Detectors for Jia Use
GB 15322.3-2019 Combustible Gas Detectors Part 3: Portable Combustible Gas Detectors for Industrial and Commercial Use
GB 4715-2024 Point type Smoke Fire Detector
GB 20517-2006 Independent Smoke and Fire Detection Alarm GB 30122-2013 Independent Temperature and Fire Detection Alarm
Equipment function:
The standard cigarette box consists of the main body of the box, a photoelectric smoke density meter, a heater, a refrigeration unit, an interference light source device, an industrial computer, etc., in accordance with the standard specifications and parameter requirements. Equipped with a built-in photoelectric smoke density meter, it is used to detect the smoke concentration value inside the smoke body. The imported component photoelectric smoke density meter adopts an optical design to suppress the influence of environmental temperature on the sensor, ensuring the accuracy and stability of the test. The device is equipped with an internal heater and an external refrigeration unit to automatically control the temperature inside the box. When using a smoke fire detector, reduce the temperature to 0 °+/-2 ° C or increase it to 55 °+/-2 ° C at a rate of less than 1C/min, and test the sensitivity value of the smoke detector in high and low temperature environments. When testing a temperature detector, the heating rates can be set to 1 ° C/min, 3 ° C/min, 5 ° C/min, 10 ° C/min, 20 ° C/min, and 30 ° C/min. The highest temperature may reach 160 ° C. The testing software can adjust the wind speed, smoke rise rate, and temperature to meet the standard testing requirements. The Zontest Smoke Test Tunnel software, specially developed, has built-in testing parameters. By selecting the corresponding testing items, the software can automatically run the test program. The software continuously monitors smoke concentration, smoke rise rate, and temperature rate, and records detector sensitivity values.
Main technical parameters
Equipment dimensions: approximately L4500mmxW1200mmxH2000mm1
Test area size: approximately 400mmx400mm
Test wind speed: 0.8m/s ± 0.2m/s
4. Fan speed range: 0 m/s~6.5 m/s continuously adjustable
5. Test temperature: -40 ℃~75 ℃ adjustable (using imported compressor refrigeration)
6. Heating rate: ≤ 1 ℃/min (non-linear without load)
7. Temperature measurement accuracy: ± 0.5 ℃
8. Resolution: 0.1 ℃
9. Temperature deviation: ≤+2 ℃
10. Test humidity: 93%+3%, adjustable humidity range: 90%~96%; Humidification rate<5%/min, no load nonlinearity)
11. Humidity measurement accuracy: relative error not exceeding ± 0.5%
12. Resolution: 0.10%
13. Humidity deviation: ≤+3%
14. Wind speed: Anemometer measurement range: 0.2m/s~10 m/s; Measurement error:+5%: Resolution: 0.1m/s
15. Test control: intelligent control system, computer display, corresponding test process display
Test the curve of the project
16. Time parameter: 0~99min99s+0.1s
17. Azimuth angle rotation angle: 0~360 °, each rotation angle: 45