Finnish mirion DMC 3000 personal dosimeter

NegotiableUpdate on 01/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The Finnish mirion DMC 3000 personal dosimeter can provide the wearer with clear dose values and depth dose equivalent peripheral dose rate values, as well as sound, light, and vibration alarms. The French MGP DMC3000 personal dosimeter has a wider measurement range than the DMC2000S, and the operation method is basically the same as the DMC2000S. It is a good upgrade choice for customers who are accustomed to using the DMC2000S.
Product Details

Finnish mirion DMC 3000 Personal DosimeterProduct Introduction:

Finnish mirion DMC3000 personal dosimeterIt is a model produced by Mirion Corporation in Finland that can replace the DMC2000,

The French MGP DMC3000 personal dosimeter has a wider measurement range than the DMC2000S, and the operation method is basically the same as the DMC2000S. It is a good upgrade choice for customers who are accustomed to using the DMC2000S.

The DMC 3000 electronic dosimeter is a product that has been continuously improved based on 25 years of practical experience and user feedback. It has the ability to detect X-ray and gamma ray radiation covering a wide energy range.

Its high-resolution backlit LCD display provides clear dose values and depth dose equivalent peripheral dose rate values to the wearer. More importantly, it uses multiple methods (auditory, visual, and tactile) to alert the wearer of alarm situations.



Finnish mirion DMC 3000 Personal DosimeterProduct Features:

This surface contamination detector is used at the exit of the control area to measure the gamma radiation of objects.
The detector and measuring electrical unit can self test
Pollution monitoring can automatically calculate background
Based on the background threshold, the device can automatically determine the appropriate measurement time by setting the credibility
Sound and light indication alarm output to the outside
Display pollution level (Cps or Bq)
Printing of measurement results (optional)


Finnish mirion DMC 3000 personal dosimeterTechnical Specifications:

Detecting radiation: x, γ

Measurement range: Dose rate: 0.01mSv/h-10Sv/h or 0.001 mSv/h-10Sv/h (extended); Dose: 1 μ Sv-10Sv

Energy range: 15keV -7MeV

Detector: GM counter tube

Working temperature: -10 ° C~50 ° C

Power supply mode: one AAA battery

Size and quality: 87 × 60 × 21mm, 84g

Data transmission: via reader (LDM 2000)