Typical applications for measuring solar spectral irradiance include scientific meteorology, climate observation, material testing research, evaluation of solar panel efficiency, and renewable energy sources. The FieldSolar-F series all-weather spectroradiometer launched by Avantes in the Netherlands is a tool for measuring outdoor spectral characteristics.
This series of devices has two optional probe configurations, one for measuring the direct spectrum of the sun (connected to a sun tracking system through a 5-degree cosine correction probe), and the other for measuring the total solar radiation (through an all day cosine receiving probe). In addition, the spectral range can also be selected as needed.
characteristic:
1. New spectroscopic technology with over 1000 sampling channels, capable of distinguishing more spectral details;
2. The spectral data is traced back to the NIM standard light source and a calibration report from the Chinese Academy of Metrology is provided;
3. Nonlinear calibration technology ensures response consistency close to 100%;
4. Automatically control the spectral radiometer to measure irradiance based on the rise and fall time of the sun;
5. Automatically optimize exposure time and deduct dark current;
6. Equipped with a large capacity storage chip, it can store annual spectral data for more than 2 years;
7. Built in uninterruptible power supply, with a battery life of up to 2 hours;
8. Equipped with a network port for reading data and maintaining system software;
9. Equipped with a professional outdoor thermostat to ensure that the working temperature of the instrument remains constant at 20-25 degrees Celsius;
10. Protection level IP55.

FieldSolar-1-F |
FieldSolar-2-F |
FieldSolar-3-F |
||
spectral range |
250 - 1100 nm |
250 - 1700 nm |
250 - 2500 nm |
|
spectral resolution |
1.5 nm @ 250 -1100 nm |
1.5 nm @ 250 -1100 nm 5.7 nm @ 1050-1700 nm |
1.5 nm @ 250 -1100 nm 15 nm @ 1050-2500 nm |
|
Spectral sampling interval |
0.6 nm @ 250 -1100 nm |
0.6 nm @ 250 -1100 nm 1.5 nm @ 1050-1700 nm |
0.6 nm @ 250 -1100 nm 6 nm @ 1050-2500 nm |
|
Wavelength accuracy |
± 0.2 nm @ 250 -1100 nm |
± 0.2 nm @ 250 -1100 nm ±0.5 nm @ 1050-1700 nm |
± 0.2 nm @ 250 -1100 nm ±1 nm @ 1050-2500 nm |
|
Wavelength Repeatability |
± 0.1 nm @ ± 10 ° C temperature variation |
|||
detector |
Back illuminated CCD detector, 2048 pixels, pixel size 14x500um |
Back illuminated CCD detector, 2048 pixels, pixel size 14x500um; 512 pixel InGaAs array, TE cooling |
Back illuminated CCD detector, 2048 pixels, pixel size 14x500um; 256 pixel InGaAs array, TE cooling |
|
Signal to Noise Ratio |
525:1@ 250 -1100 nm |
525:1@ 250 -1100 nm 5000:1 @1050-1700 nm |
525:1@ 250 -1100 nm 4000:1 @1050-2500 nm |
|
Integral (exposure) time |
2us-20s, automatic optimization |
|||
AD conversion |
16 bits, up to 65536 |
|||
Range of pan tilt angle |
Horizontal 0-350 °; Pitch 0-90 ° |
|||
PTZ positioning accuracy |
±0.1° |
|||
PTZ repeatability accuracy |
±0.1° |
|||
communication interface |
Standard RJ45 Ethernet port |
|||
operation temperature |
-40℃~ +65℃ |
|||
Working humidity |
0-90% RH (non condensing) |
|||
Power supply mode |
AC 220 V,50Hz |
|||
Standard accessories:
1. Standard Ethernet cable;
2. All day daylight cosine probe.
Optional accessories:
1. 5 ° field of view cosine probe for direct sunlight