Welcome Customer !

Membership

Help

Shanghai Hengyi Electromechanical Equipment Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shanghai Hengyi Electromechanical Equipment Co., Ltd

  • E-mail

  • Phone

  • Address

    Building 609, Wanda Building 9, Jiangqiao, Shanghai

Contact Now

FS-4 American GEMS flow switch

NegotiableUpdate on 05/12
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The FS-4 GEMS flow switch provides cost-effective flow protection for various industrial applications such as welding equipment, lubricating oil systems, medical sterilization equipment, and detergent distribution.

Product Details

FS-4 American GEMS flow switchtraffic setting:0.1GPM~1.5GPM
FS-4 American GEMS flow switchinterface9/16”-18 UNF
main structureRyton®
Set typefixed type

Provides cost-effective flow protection for various industrial applications such as welding equipment, lubricating oil systems, medical sterilization equipment, and detergent distribution.

performance parameters

wetted material
Shell and piston

Ryton®R4

spring

316 stainless steel

o-ring

Viton®

Other parts that come into contact with the medium

epoxy resin

work pressure

250 PSIG @ 70oF (21oC)

Operating Temperature

0oF to 225oF (-17oC ~ +107oC)

Set point accuracy

±15% Max

Set point deviation

20% Max

Switch*

SPST or SPDT, 20VA (SPDT: 240VAC max)

interface

9/16 "-18UMF-2B thread

Electrical connection

SPST 18AWG,Zipcord, 24 inches long

SPDT 18AWG,PVC, 24 inches long

*Can provide polysulfone shell and connector

Ordering Guide

Shell and piston material

Flow setting value

Part Number

SPST switch

SPDT switch

Always open when there is no traffic

No traffic often closed

Ryton®

0.1

122340

122346

122352

0.25

122341

122347

122353

0.5

122342

122348

122354

0.75

122343

122349

122355

1.0

122344

122350

122356

1.5

122345

122351

122357

Precautions
The flow setting is calibrated with increasing water flow at+70 ° F, with the switch in a vertical position (wire up).
2. Ensure that the fluid is compatible with the liquid receiving materials listed in the table above.
3. It is recommended to use a nozzle adapter when changing from 9/16 "-18UNF straight thread to the user's desired nozzle size. 4. Use a 50 micron or better filter.

The nozzle adapter

Convert 9/16 "threaded ports to NPT or barbed connections. Using Ryton ®- R4 O-ring. Warning: When installing the adapter connector, do not exceed the maximum torque of 15 in./l bs.

material

size

Part Number

Ryton®

1/8” NPT

123028

1/4” NPT

123029

polypropylene

1/4” NPT

158602

1/2” Barb

158603