FFKM (Perfluoroether) glass rotor flowmeter

NegotiableUpdate on 05/25
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

FFKM (Perfluoroether) glass rotor flowmeter PVDF glass rotor flowmeter is a process detection instrument for measuring the flow rate of single-phase non pulsating fluid (liquid or gas) in a closed pipeline. It is suitable for measuring strongly corrosive media and has the advantages of resistance to strong acid and alkali corrosion, high strength of PVDF material, and strong corrosion resistance

Product Details

DK900Glass rotor flowmeter

FFKM (perfluoroether) glass rotor flowmeter SC900 glass rotor flowmeter glass rotor flowmeterPVDF glass rotor flowmeter SC900 glass rotor flowmeterOverview

FFKM (perfluoroether) glass rotor flowmeter SC900 glass rotor flowmeter glass rotor flowmeterPVDF glass rotor flowmeterDK900Glass rotor flowmeter is a process detection instrument for measuring the flow rate of single-phase non pulsating fluid (liquid or gas) in a closed pipeline. It is suitable for measuring strongly corrosive media and is resistant to strong acid and alkali corrosion,PVDFAdvantages such as high material strength and strong corrosion resistance

FFKM(全氟醚)玻璃转子流量计

New corrosion-resistant instrument developed by Changzhou Shuangcheng Thermal Instrument Co., LtdPVDFProducts made of materials, with complete specifications and varieties, advanced manufacturing technology, stable and reliable quality,FFKM (Perfluoroether) glass rotor flowmeterSC900 glass rotor flowmeter glass rotor flowmeterPVDF glass rotor flowmeter SC900The series of glass rotor flow meters are widely used in chemical, petroleum, light industry, pharmaceutical, fertilizer, synthetic fiber, food, dye, papermaking, national defense, scientific research and other units. They can also be customized with special flow rates and materials for customers.

The glass rotor flowmeter, manufactured with professional technology and equipment, has advantages such as high measurement accuracy, good interchangeability, wide measurement range, multiple connection methods, and easy installation and maintenance compared to similar domestic products. In addition, it can provide users with flow scales for different fluids, states, and viscosities based on their physical quantities such as temperature, pressure, density, and viscosity, solving the problem of correcting measurement display values and facilitating user use.

FFKM(全氟醚)玻璃转子流量计

working principle

FFKM (perfluoroether) glass rotor flowmeter SC900 glass rotor flowmeter glass rotor flowmeterPVDF glass rotor flow rate SC900The series glass rotor flowmeter is a variable area flowmeter, mainly composed of a vertically expanding glass cone tube from bottom to top and a float that can move up and down with the flow rate (see Figure 1). When the fluid flows through the glass cone tube from bottom to top, the fluid can generate lift on the floatSThe buoyancy of fluidsARaise the float, as the annular flow area between the float and the inner wall of the cone tube increases, the lift generated by fluid kinetic energy on the float decreases accordingly. When liftSWith buoyancySThe sum is equal to the weight of the float itselfGWhen the float is in equilibrium, it stabilizes at a certain height, which represents the flow rate of the fluid through the flowmeter. Because there is a certain proportional relationship between the flow rate through the flowmeter and the rising height of the float, that is, the flow area of the flowmeter, the height position of the float can be used as two degrees of flow rate.

FFKM(全氟醚)玻璃转子流量计

one900Glass rotor flowmeter

FFKM (perfluoroether) glass rotor flowmeter SC900 glass rotor flowmeterDK900Professional technology and equipment manufacturing of series glass rotor flow meters, with different installation methods according to their purpose and structural characteristics. There are various types such as ordinary, corrosion-resistant, panel type, etc., suitable for measuring small flow rates.DK900The series of glass rotor flow meters can be easily replaced with glass cone tubes and floats without the need to remove them from the pipeline. among whichDK900-2Type can measure extremely small flow rates, with a small measurement range up to water0.002L/h,air0.1L/h


Technical Specifications Table

(1)measurement range

Water(20℃)0.002~160L/h

air1.2X10⁵pa,200.1~4300L/h

(5)浮子形状:球型 tapered

(6)Allow the condition of the fluid being tested

High pressure:1.0Mpa, 1.6Mpa

Medium temperature: -5~+120

Ambient temperature-20~+100

-20~+165

(2)Scope:1:10

(7)Overall length:145mm

(3)Accuracy level: 2.5level 4level

(8)Connection method:1/4NPTinternal thread

(4)Cone tube: Light tube, Reinforced pipe

Length:100mm

ruler Flow scale

(9)Weight:0.4Kg

Note: Introducing advanced standards for calculating the accuracy level of flow metersVDI/VDE3513Error taking1/4reference error+3/4relative error

Model specification table

path(mm)

model

Measurement range(L/h

Water(20℃)

air

1.2X10⁵pa,20

2

SC900-2


0.002~0.02

0.004~0.04

0.1~1.3

0.5~2.7



4



SC900-4




0.25~2.5

0.5~5

0.8~8

1.6~16

4~40

6~60




6



SC900-6


0.5~5

1.2~12

2.5~25

4~40

6~60

10~100

16~160

100~1000 180~1800

25~250 240~2400

50~500 240~2400

80~800 350~3500

100~1000 430~4300


Contact measurement of fluid component materials

model

Component materials

float

base

stop file

Sealing rings and gaskets

needle valve

SC900-( )

Agate or stainless steel coated with PTFE

PVDF

fluoroplastic

Fluororubber or solvent resistant rubber

PEK

Note: Special materials316or316LThe material can be customized


Outline and installation dimension diagram


FFKM(全氟醚)玻璃转子流量计


model

SC900-2

SC900-2F

SC900-46

SC900-4F,6F

D(mm)

φ9

φ11.5

E(mm)

M8X1

M10X1

Outer diameter of metal tube(mm