FB3351GT flange pressure liquid level intelligent transmitter | FB3351GT liquid level transmitter | FB3351GT

NegotiableUpdate on 12/03
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The FB3351GT flange pressure and liquid level intelligent transmitter is based on the FB3351T intelligent pressure transmitter, and is formed by adding a welded sealed isolation diaphragm structure. It is combined with advanced microcontroller technology and sensor digital conversion technology, and assembled through strict process assembly

Product Details

application

The FB3351GT flange pressure liquid level intelligent transmitter is formed by adding a welded sealed isolation diaphragm structure on the basis of the FB3351T intelligent pressure transmitter, and combining advanced microcontroller technology and sensor digital conversion technology, assembled through strict process.

Its welding sealing isolation membrane device has various forms of flange connection structures, which are used for liquid level measurement of open containers. It is particularly suitable for pressure, liquid level, and density measurement in high temperature, high viscosity, crystalline media, and easily clogged situations. It is also suitable for pressure measurement in the food, pharmaceutical, and pulp and paper industries.

«feature

★ Low temperature impact, high repeatability, and good long-term stability;

The isolation membrane material can be selected from various materials such as 316L stainless steel, Hastelloy C-276, tantalum, etc;

The process connectors are made of 304 stainless steel and have multiple standard flange installation forms;

«Technical Specifications

● Working voltage

12~30VDC

● Output signal

4~20mADC, Equipped with intelligent HART fieldbus protocol.

● Accuracy

±0.25%

● Temperature impact

≤ (0.08 · r+0.1)%/10 ℃ (r=maximum range/set range)

● Stability

≤± 0.1% F.S/12 months

● Location impact

The installation position does not affect the zero point

● Environmental temperature

-20℃~+70℃

● Medium temperature

-20℃~+130℃

● Preheating time

<15 seconds

● Vibration impact

When the vibration frequency is (20-200) Hz in any direction, the change is less than ± 0.02% F.S

● Impact impact

After a 100G impact in any direction for 11ms, the change is less than ± 0.02% F.S

● Protection level

Better than IP65

Explosion proof type

Explosion proof Exd Ⅱ CT6; The intrinsic safety Exia Ⅱ CT6 should be equipped with an external safety barrier

● Load characteristics

The relationship between load impedance RL and power supply voltage V is RL ≤ 50 (V-12) (Ω)

Note: When communicating with a computer or handheld communicator, the RL is between 230 Ω and 600 Ω

● Structural materials

Shell: Polyurethane baked paint low copper cast aluminum alloy

Isolation membrane material: 316L stainless steel, tantalum, Hastelloy C, 316L with ETFE anti sticking layer

Process connector material: 304 stainless steel

Filling fluid: Silicone oil

● Electrical connection

It can be led out from any outlet as needed, suitable for industrial cables with diameters ranging from φ 8.5 to φ 10.0 as leads for sealing The universal cable connector PG16 or M20 × 1.5 can be used for the lead out joint, and the non lead end should be sealed with an end cap

«Selection Table

FB3351GT

Intelligent transmitter for flange pressure and liquid level

code name

measurement range

06

0~50kPa~70kPa

07

0~70kPa~100kPa

08

0~70kPa~200kPa

09

0~100kPa~350kPa

10

0~200kPa~700kPa

11

0~350kPa~1.0MPa

12

0~700kPa~2.0MPa

13

0~1.0MPa~3.5MPa

code name

output

S

Intelligent 4-20mADC two-wire system+fieldbus HART protocol

9

Special requirements

code name

Structural materials

Nominal diameter (mm)

Insertion tube length (mm)

Isolation membrane material

G0

50

flat

316L (stainless steel)

A0

80

flat

316L (stainless steel)

A2

80

50

316L (stainless steel)

A4

80

100

316L (stainless steel)

A6

80

150

316L (stainless steel)

B0

100

flat

316L (stainless steel)

B2

100

50

316L (stainless steel)

B4

100

100

316L (stainless steel)

B6

100

150

316L (stainless steel)

G2

50

flat

Ha Shi C-276

C0

80

flat

Ha Shi C-276

G4

50

flat

Tantalum

E0

80

flat

Tantalum

G6

50

flat

316L with ETFE anti sticking layer

A8

80

flat

316L with ETFE anti sticking layer

code name

Installation flange specifications

A

2〞150LB

B

2〞300LB

C

3〞150LB

D

3〞300LB

E

4〞150LB

F

4〞300LB

G

DN50 PN16/25/40

H

DN80 PN16

I

DN80 PN25/40

J

DN100 PN16

K

DN100 PN25/40

code name

Install flange material

1

carbon steel

2

316SST

code name

Measure the temperature of the medium

1

Room temperature type (≤ 70 ℃)

2

High temperature type (≤ 130 ℃)

code name

Optional parts (if not selected, do not fill in)

M3

3 1/2LCD digital display header

d

Explosion proof dIICT6

i

Intrinsically safe iaIICT6

S

Process connectors

Y

User agreement

FB3351GT

08

S

G0

G

1

1

M3

Example of transmitter selection

Explanation: If the temperature of the measured medium continues to reach 130 ℃ or below -20 ℃, it is recommended to use a temperature isolator or capillary structure to ensure that the sensor is not damaged.