★ Overview
FB1151LT liquid level transmitter is a field transmitter directly installed on pipelines or containers. Due to the direct contact between the isolation membrane and the liquid-phase medium, there is no need to use the positive pressure side
The pressure tube is used to measure the liquid level, pressure, and density of media such as high temperature, high viscosity, easy crystallization, easy precipitation, and strong corrosion, and then convert them into 4-20mA signals for transmission
Get out. The FB1151LT liquid level transmitter adopts standard flanges for installation and connection, with flat flanges and insert flanges for users to choose from. Install flanges according to ANSI 2-inch and 3-inch standards
4 inches, nominal pressure according to 150LB and 300LB standards. Flange diaphragm materials include 316L, Hastelloy, Monel, Tantalum, etc.
★ Features
Exquisite exterior design
● Adopting a two-line working mode
Using solid circuit components, the printed circuit board has a plug-in method
Unique structural design, sturdy and strong seismic resistance
The range and zero position can be continuously adjusted externally
Positive migration can reach 500%, negative migration can reach 600%
● Adjustable damping
★ Technical parameters
※ Technical indicators
● Target liquid for use
Measurement range: 0-6.2 KPa to 0-2068 KPa
Output 4-20mADC
Power supply 24V DC, can operate at 12V DC (with LCD display minimum 15VDC), maximum 45V DC
Regardless of the output, after positive and negative migration, the upper and lower limits of the range must not exceed the limit of the range.
Maximum migration amount: 500% of the minimum calibration range
Maximum negative transfer: 600% of the minimum calibration range
Temperature range for storage: -40 to+70 ℃
Amplifier operating temperature range (ambient temperature): -30 ℃ to+70 ℃
Working temperature (medium temperature) of silicone oil filled measuring element: -40 ℃ to+149 ℃
The relative humidity range is 1-100%
The volume change of the sensor is less than 0.16cm3
● Indicator (on-site) pointer type; digital display
Explosion proof type and explosion-proof type ExdIICT6; Intrinsic safety ExiaICT6
● Range and zero point are continuously adjustable externally
● Overpressure limit 150LB: 1.97MPa; 300LB:5.1MPa
Damping can be continuously adjusted between 0.2 and 16 seconds
● Start time of 2 seconds, no preheating required
※ Performance indicators
Accuracy ± 0.5%
Stability<± 0.25% FS/year
Temperature impact ≤± 0.60% (change every 28 ℃ at maximum range)
Static pressure impact ≤± 0.60% (at maximum range)
Vibration affects any axis at a frequency of 200Hz, causing an error of less than ± 0.05% of the maximum range. The range code 2 (micro differential pressure) is ± 0.25%
The impact of the power supply is less than 0.005%/V of the output range
When the load affects the stability of the power supply, there is no load impact
The installation position can generate a maximum zero point error of 0.24KPa, but it can be calibrated and has no impact on the measurement range
※ Performance indicators
● Structural material isolation membrane: 316 stainless steel, Hastelloy C, Monel alloy, tantalum
O-ring (medium contact area): Fluororubber, PTFE
Flange: 316 stainless steel
Filling fluid: silicone oil or inert oil
Electrical casing: polyurethane baked paint low copper cast aluminum alloy
The connection screw hole of the pressure connector on the pressure chamber is 1/4NPT, and the connection screw hole on the pressure connector is 1/2NPT. The center distance is shown in the external dimension drawings of various models, and the signal cable connection screw hole is M20 × 1.5
● Shell protection level IP65
★ Selection Table
|
FB1151LT |
Capacitive flange level transmitter |
|||||||||
|
┆ |
code name |
Range (kPa) |
||||||||
|
┆ |
4 |
0-6.2~37.4 |
||||||||
|
┆ |
5 |
0-31.1~186.8 |
||||||||
|
┆ |
6 |
0-117~690 |
||||||||
|
7 |
0-345~2068 |
|||||||||
|
┆ |
┆ |
code name |
output |
|||||||
|
┆ |
┆ |
E |
4-20mADC |
|||||||
|
┆ |
┆ |
S |
intelligent type |
|||||||
|
┆ |
┆ |
┆ |
code name |
Structural materials |
||||||
|
┆ |
┆ |
┆ |
Nominal diameter (mm) |
Insertion tube length (mm) |
High voltage side isolation diaphragm material |
|||||
|
┆ |
┆ |
┆ |
G0 |
50 |
flat |
316L (stainless steel) |
||||
|
┆ |
┆ |
┆ |
A0 |
80 |
flat |
316L (stainless steel) |
||||
|
┆ |
┆ |
┆ |
A2 |
80 |
50 |
316L (stainless steel) |
||||
|
┆ |
┆ |
┆ |
A4 |
80 |
100 |
316L (stainless steel) |
||||
|
┆ |
┆ |
┆ |
A6 |
80 |
150 |
316L (stainless steel) |
||||
|
┆ |
┆ |
┆ |
B0 |
100 |
flat |
316L (stainless steel) |
||||
|
┆ |
┆ |
┆ |
B2 |
100 |
50 |
316L (stainless steel) |
||||
|
┆ |
┆ |
┆ |
B4 |
100 |
100 |
316L (stainless steel) |
||||
|
┆ |
┆ |
┆ |
B6 |
100 |
150 |
316L (stainless steel) |
||||
|
┆ |
┆ |
┆ |
G2 |
50 |
flat |
Ha Shi C-276 |
||||
|
┆ |
┆ |
┆ |
C0 |
80 |
flat |
Ha Shi C-276 |
||||
|
┆ |
┆ |
┆ |
G4 |
50 |
flat |
Tantalum |
||||
|
┆ |
┆ |
┆ |
E0 |
80 |
flat |
Tantalum |
||||
|
┆ |
┆ |
┆ |
┆ |
code name |
Install flange |
|||||
|
┆ |
┆ |
┆ |
┆ |
A |
3〞150LB |
|||||
|
┆ |
┆ |
┆ |
┆ |
B |
4〞150LB |
|||||
|
┆ |
┆ |
┆ |
┆ |
C |
3〞300LB |
|||||
|
┆ |
┆ |
┆ |
┆ |
D |
4〞300LB |
|||||
|
┆ |
┆ |
┆ |
┆ |
E |
2〞150LB |
|||||
|
┆ |
┆ |
┆ |
┆ |
F |
2〞300LB |
|||||
|
┆ |
┆ |
┆ |
┆ |
G |
DN50 PN2.5/4.0 |
|||||
|
┆ |
┆ |
┆ |
┆ |
H |
DN80 PN2.5/4.0 |
|||||
|
┆ |
┆ |
┆ |
┆ |
I |
DN100 PN2.5/4.0 |
|||||
|
┆ |
┆ |
┆ |
┆ |
┆ |
code name |
Structural materials |
||||
|
┆ |
┆ |
┆ |
┆ |
┆ |
Flanges and fittings |
Exhaust/Drain Valve |
Low voltage side isolation diaphragm material |
|||
|
┆ |
┆ |
┆ |
┆ |
┆ |
22 |
316SST |
316SST |
316L (stainless steel) |
||
|
┆ |
┆ |
┆ |
┆ |
┆ |
23 |
316SST |
316SST |
Hastelloy C alloy |
||
|
┆ |
┆ |
┆ |
┆ |
┆ |
24 |
316SST |
316SST |
Monel alloy |
||
|
┆ |
┆ |
┆ |
┆ |
┆ |
25 |
316SST |
316SST |
Tantalum |
||
|
┆ |
┆ |
┆ |
┆ |
┆ |
┆ |
code name |
Optional parts (if not selected, do not fill in) |
|||
|
┆ |
┆ |
┆ |
┆ |
┆ |
┆ |
M1 |
0-100% linear indicator table |
|||
|
┆ |
┆ |
┆ |
┆ |
┆ |
┆ |
M3 |
LCD meter, displaying units from 0 to 100% |
|||
|
┆ |
┆ |
┆ |
┆ |
┆ |
┆ |
B1 |
Pipe bending installation plate |
|||
|
┆ |
┆ |
┆ |
┆ |
┆ |
┆ |
B2 |
Plate bending installation plate |
|||
|
┆ |
┆ |
┆ |
┆ |
┆ |
┆ |
B3 |
Pipe installation safety installation board |
|||
|
┆ |
┆ |
┆ |
┆ |
┆ |
┆ |
D1 |
The side relief valve is located at the upper part of the pressure chamber |
|||
|
┆ |
┆ |
┆ |
┆ |
┆ |
┆ |
D2 |
The side relief valve is located at the lower part of the pressure chamber |
|||
|
┆ |
┆ |
┆ |
┆ |
┆ |
┆ |
C1 |
1/2-14NPT pressure joint rear welded pressure pipe with a diameter of 14 |
|||
|
┆ |
┆ |
┆ |
┆ |
┆ |
┆ |
C2 |
T-shaped external thread joint M20X1.5 |
|||
|
┆ |
┆ |
┆ |
┆ |
┆ |
┆ |
C3 |
1/2-14NPT taper pipe female thread joint |
|||
|
┆ |
┆ |
┆ |
┆ |
┆ |
┆ |
d |
Explosion proof ExdIICT6 |
|||
|
┆ |
┆ |
┆ |
┆ |
┆ |
┆ |
i |
Intrinsically safe ExiaICT6 |
|||
|
FB1151LT |
4 |
E |
A0 |
B |
22 |
M1 |
Example of transmitter selection |
|||
Note: Other dimensions for flange installation will be ordered separately.