Product Description Detailed Parameters Technical Parameters: Input Range: 5-999990RPM Speed below 5RPM may have multiple pulses per revolution (0.083Hz-250kHz) Input Configuration and Voltage Range: 1-9999 pulses per revolution or connect to a computer to program using one parameter set to 0.0001-99999

Product Details

  • Product Details
  • detailed parameters

Technical parameters:
Input range: 5-999990RPM. If the speed is below 5RPM, there may be multiple pulses per revolution (0.083Hz-250kHz)
Input configuration and voltage range: 1-9999 pulses per revolution or connect to a computer to program using a parameter set to 0.0001-99999, TTL input and 1.1V to 25Vdc signal - internally adjusted to: ± 1 to ± 25Vac
Analog signal output: Isolation voltage output: 0-5VDC, maximum load of 5mA, isolation current output: 4-20mA Isolated, maximum load of 500 ohms, internal 12V constant current output voltage, 16 bit resolution, can be connected to a computer to set full-scale output or compensate for speed range
Accuracy/Resolution: Full scale output of 0.005%/76 μ volts or 30.5 Nano amps
Output update frequency: can reach 244 times/second through software settings, depending on the input frequency
Storage: Retrieve the maximum and minimum values through PM software
Size: 1/8DIN standard, depth 100mm
Input power supply: standard 12-24Vdc, maximum power 4.5W or optional 12-24Vdc, maximum power 5W isolated input
Sensor power supply: standard configuration 10Vdc@60mA Or optional 5Vdc@60mA
Pulse relay output: compatible with 0-5V TTL, input and output pulses can be selected for polarity through software
Communication: Standard USB B-type interface, optional Ethernet communication interface
Alarm function: An optional alarm relay can be selected, which can be set to high value, low value alarm, or locked or non locked. It can be set by connecting to a computer
Alarm output: C-type alarm relay, rated at 1A 115Vac or 230Vac
Alarm reset: automatic or manual reset, front panel button or remote control through computer
Usage environment: indoor use, installation category II according to IEC664
Temperature: -10 ° C-50 ° C according to IEC 61010-1
Humidity: Maximum relative humidity 80% 31 ℃, linearly decreasing to relative humidity 50% 40 ℃