l7-inch LCD touch screen, Chinese display, easy to operate, intuitive display
l*The heating and cooling power ensures rapid heating and cooling effects during the test process
lWide temperature range, no need to replace the medium within the entire temperature control range
lCHEMsystem control system, based on Siemens PLC design, can accurately control and display temperature in real time, and draw trend curves
lOil temperature control, material temperature control, and temperature difference control, switchable control
lMeasurement data can be saved in Excel format for easier browsing, editing, and sending
lReal time display of equipment operation status, automatic diagnosis of fault information, and more intuitive and convenient maintenance and use
lConfigure RS485 communication interface,ModbusRTUagreement
lCompact design, elegant and space saving
lCustomized solutions can be provided according to different application needs

performance parameters
| model | TEM-225 | TEM-235 | TEM-255 | TEM-275 | TEM 2100 | TEM 2150 | |
| temperature range | -25℃~+200℃ | ||||||
| programmable | 9-stage temperature time program | ||||||
| temperature feedback | Thermal medium temperature feedback PT100 Material temperature feedback PT100 | ||||||
| temperature fluctuation | ±0.1℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | |
| heating power | 2.5KW | 6KW | 6KW | 9KW | 12KW | 15KW | |
| cooling capacity
| 200℃ | 2.5KW | 3.5KW | 5.5KW | 7.5KW | 10 KW | 15 KW |
| 100℃ | 2.5 KW | 3.5 KW | 5.5 KW | 7.5 KW | 10 KW | 15 KW | |
| 20℃ | 2.5 KW | 3.5 KW | 5.5 KW | 7.5 KW | 10 KW | 15 KW | |
| -5℃ | 2.0 KW | 3.0 KW | 4.5 KW | 6.3KW | 8.1KW | 12 KW | |
| -20℃ | 1.0 KW | 1.8 KW | 2.8KW | 3.8KW | 4.6 KW | 7.2 KW | |
| circulation pump | pressure | 2bar | 2bar | 2bar | 2bar | 2.5bar | 2.5bar |
| traffic | 35L/min | 35L/min | 50L/min | 50L/min | 50L/min | 110L/min | |
| refrigerant | R-404A | ||||||
| interface dimensions | DN15 | DN20 | DN20 | DN20 | DN20 | DN25 | |
| communication protocol | Moubuscommunication protocolRS485interface | ||||||
| power supply | AC220V50Hz | AC380V 50Hz | |||||
| Optional one | Temperature range extended to-25℃~+250 ℃ (add T after model) | ||||||
| Option 2 | Temperature range extended to-25℃~+300 ℃ (add V after model) | ||||||
| Optional three | Water cooled type can be selected (model added later)W) | ||||||
safety protection
| Coolant over temperature protection | Compressor high and low pressure protection, overcurrent protection, overheating protection |
| Pipeline overpressure alarm | Water tank refill reminder |
| Pump overload alarm | Automatic exhaust upon startup |
The usage and maintenance methods of the explosion-proof hot and cold integrated machine are as follows:
Management personnel and operators should be familiar with the product manual and operation process of the equipment, and operate and store the explosion-proof hot and cold integrated unit properly. Operators of non explosion proof integrated cooling and heating units should not use the equipment easily.
Before use, in addition to the above steps, it is recommended to check whether the external factors such as usage environment, power supply, temperature, etc. are within a reasonable range, and try to place the device on as required. Avoid moisture, dust, and corrosion, and ensure that the explosion-proof hot and cold integrated unit is not affected by external factors during operation.
During operation, if there is a malfunction, please contact the manufacturer of the explosion-proof integrated cooling and heating unit for resolution. Do not attempt to resolve it on your own, as this may lead to a secondary malfunction.
Regular maintenance work is required, including keeping records and cleaning regularly.