Welcome Customer !

Membership

Help

Jiangsu Daya Automatic Control Equipment Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Jiangsu Daya Automatic Control Equipment Co., Ltd

  • E-mail

  • Phone

  • Address

    No. 12 Jinhu Road

Contact Now

Explosion proof electric contact pressure gauge

NegotiableUpdate on 05/12
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

YX-100-B explosion-proof electrical contact pressure gauge $r $n YX-100-B explosion-proof electrical contact pressure gauge is designed according to the relevant provisions and standards of GB3836.1 83 "General Requirements for Explosion proof Electrical Equipment for Explosive Environments" and GB3836.2 83 "Explosion proof Electrical Equipment for Explosive Environments - Explosion proof Electrical Equipment" d ", and manufactured with approved drawings and technical documents by inspection agencies. The explosion-proof category of $r $nYX-100-B is Class II explosion-proof type B level T4 group, and its symbol is Exd Ⅱ CT6.

Product Details

YX-100-BExplosion proof electric contact pressure gauge

YX-100-BExplosion proof electric contact pressure gaugeThe design is carried out in accordance with the relevant provisions and standards of GB3836.1 83 "General Requirements for Explosion proof Electrical Equipment for Explosive Environments" and GB3836.2 83 "Explosion proof Electrical Equipment for Explosive Environments - Explosion proof Electrical Equipment" d ", and manufactured with approved drawings and technical documents by inspection agencies.

The explosion-proof category of YX-100-B is Class II flameproof type B level T4 group, with the symbol Exd Ⅱ BT4.

YX-100-B is suitable for measuring the pressure of non crystalline, non solidified explosive mixtures or various non explosive media in places with explosive hazards.

YX-100-B can be used in conjunction with electrical components (such as relays and contactors) with corresponding explosion-proof performance or safety measures to achieve automatic control and signaling (alarm) of the controlled system.

structural principle

The instrument consists of an explosion-proof shell, a measurement system, an electrical contact group, a regulating device, and an outlet box.

The explosion-proof shell of the instrument has good explosion-proof performance, so it can not only withstand the explosive pressure generated by the explosive gas mixture inside the shell in the event of an explosion due to the influence of sparks or arcs during normal operation, but also effectively prevent the heat energy generated from spreading smoothly outward, and can only slowly diffuse outward along the small gaps of the explosion-proof joint surface inside the shell. At this point, the instantaneous temperature transmitted to the outside of the shell has dropped below the ignition temperature of the explosive gas mixture, so it will not cause detonation.

The working principle of the instrument is based on the elastic deformation of the detection element (spring tube in the measurement system), which drives the contacts in the electrical contact group to produce corresponding actions (closing or opening) through mechanical transmission, so as to connect or disconnect the circuit in the voltage control system, thereby achieving the purpose of automatic control alarm and on-site indication.

Main technical indicators

Accuracy level: 1.5

Scale range:

0~0.16; 0~0.25; 0~0.4; 0~0.6; 0~1;

0~1.6; 0~2.5; 0~4; 0~6; 0~10;

0~16; 0~25; 0~40; 0~60;

-0.1~0.06; -0.1~0.15; -0.1~0.3;

-0.1~0.5; -0.1~0.9; -0.1~1.5;

-0.1~2.4MPa

Control mode: upper and lower limit slow contact switch

Maximum operating voltage: DC 220V or AC 380V;

Contact power: 10VA

Working position: Vertical installation

Environmental conditions for use: -10~50 ℃, relative humidity not exceeding 80%, and explosive mixtures should belong to Class IIB T4 or below. The working vibration and rapid pulsation of the measured medium should not affect the reliable operation of the instrument contacts.

Temperature effect: The displayed value should not exceed 0.4%/0 ℃, and the set point should not exceed 0.6%/10 ℃ (with a temperature deviation of 20 ± 5 ℃).

Insulation strength: 50Hz sine AC 2000V for one minute

Weight: 6kg


Types and basic parameters of explosion-proof joint surfaces

Shell volume V (L)

>0.5

Joint surface type

plane

Cylinder (movable part)

Minimum effective length of explosion-proof joint surface Lmm

15

Minimum effective length L1 from the edge of the screw through-hole to the explosion-proof joint surface

8

Maximum gap or diameter difference of explosion-proof joint surface Wmm

0.15

Surface roughness Ra of explosion-proof joint surface

3.2

1.6





Note: An example of the effective length and gap width of the explosion-proof joint surface can be found in the schematic diagram of the explosion-proof shell structure.

Explosion proof shell and pressure guiding system components and materials

Part Name

Material grade or name

Part Name

Material grade or name

Drive shell cover

junction box

ZL102

(or ZL-102, ZL-101)

Thin gasket

L3

connection

20

bushing

QAJ9-2

Bourdon tube

3J53

observation window

organic glass



Note: The material of the observation window has an impact resistance strength of not less than 4J. Once the observation window is damaged, it is not allowed to be used.