Systec exhaust filter sterilizer can completely block all your infectious gases on the biosafety filter cartridge. As the sterilization program runs, the filter cartridge will also undergo synchronous online sterilization, and infectious substances will not leak.
Triple security guarantee:
Only one door can be opened at a time, and when one door is opened, the other will automatically lock.
If the sterilizer is turned off or not powered on (such as in the event of a power failure), both doors remain locked.
Once the door of the non clean area is opened, a sterilization procedure must be performed before the door of the clean area is opened. The door lock system can be individually modified according to customer requirements.
The door lock system can be set according to the customer's habits. The door and control panel are made of heat-insulating plastic material, and the outer shell is made of stainless steel material with specially treated stainless steel edges. Both sides of the machine can be operated, and the status of the door will also be displayed on the screen.
Suitable for biosafety laboratories and clean rooms:
Suitable for biosafety laboratories at or above the second level, the through wall design door lock system is used to protect the biosafety laboratory from external pollution.
Suitable for clean rooms, equipped with double door high-pressure sterilizers, with a through wall design that can isolate clean and non clean areas.
Systec H series 2D double door through wall typeExhaust filter sterilizerThe use of a new automatic door lock system to close doors is so simple and yet so safe. The door lock is automatically locked by a ring lock after the lid is closed. The sealing ring made of special heat-resistant material can provide an exceptionally tight seal. The higher the pressure inside the chamber, the better the sealing performance, without the need for additional air compressors or other media.
Systec H series 2D double door through wall typeExhaust filter sterilizerThe door lock of the automatic door opening system sterilizer can be automatically opened according to needs - it can be triggered by buttons or set to automatically open after sterilization. This very simple and effective program allows residual steam to be automatically discharged from the machine, thereby avoiding affecting the sterilization process. The residual heat can be used in later stages to slightly dry sterilized items. The automatically opening door has an opening angle of approximately 15 degrees to ensure the release of steam while avoiding external contamination of the items inside the machine. Keeping sterilized items inside the machine for cooling and drying is a crucial step in the sterilization process. Once completed, if items need to be removed, the doors can be manually opened.
There are 13 models with actual volumes ranging from 90 liters to 1580 liters, which can meet the needs of various laboratory capacities. The double door sterilizer can minimize cross contamination between clean and non clean areas. Systec can provide solutions that are suitable for you, whether in terms of sterilization effectiveness or biosafety requirements.