- Phone
-
Address
Building 3, No. 85 Zijin Road, Suzhou High tech Zone
Jiapu Instrument (Suzhou) Co., Ltd
Building 3, No. 85 Zijin Road, Suzhou High tech Zone
Energy Dispersive X-ray Fluorescence Spectroscopy RoHS Directive Hazardous Elements
R-650 has the advantages of simple sample preparation, fast analysis speed, wide analysis content range, good reproducibility, and high accuracy. Based on the traditional RoHS detector, it has updated its 88 bit automatic sampling system, combining accuracy, reliability, and intuitive user experience, greatly improving product detection efficiency, providing professional elemental analysis solutions, and helping the development of multiple fields.

Technical Specifications
Sample cavity size |
400mm×340mm×80mm |
Vacuum sample chamber size |
φ100mm×h75mm |
Overall Dimensions |
700mm×510 mm×336mm |
Total weight |
56kg |
It is equipped with an 88 bit ultra large automatic sampling platform, with each sample position marked with a number, a flexible robotic arm, and an automatic opening and closing vacuum chamber. The sampling process and working curve can be independently selected, and after one-time batch production, continuous sampling and testing can be automatically carried out, which not only reduces the cost of sampling, but also greatly improves the efficiency of sampling.

Performance and principle characteristics
Scope of Elemental Analysis |
钠 (Na) ~ 铀(U) |
analysis scope |
ppm-99.99% |
detector |
Amptek Silicon Drift SDD from the United States |
measurement status |
Powder, solid, liquid |
Collimation filter system |
Collimator+multi combination filter |
resolution |
129eV±5eV |
analysis time |
Single test time adjustable |
Cooling method |
Electric refrigeration, no consumables required |
analysis precision |
Samples with RSD ≤ 0.05% (national standard sample) and content greater than 96% |
Sample environment |
Atmospheric state/Vacuum state |
working power supply |
AC 220V ±5V、50Hz |
Elemental analysis ability |
One time measurement of dozens of elements ranging from sodium (Na) to uranium (U) |
working environment |
Indoor temperature is 15-30 ℃; Relative humidity ≤ 80% (non condensing) |
Functional advantages
²Exterior design: elegant and beautiful, sturdy and durable, with multiple safety protection modes.
²Collimator filter system: collimator+multiple combination filters, software automatic switching, to meet various testing applications.
²Adopting the independently developed SES signal processing system (digital multi-channel), the peak to back ratio is effectively improved, making the measurement more accurate.
²Multi dimensional heat dissipation system: Optimized integrated heat dissipation design to greatly improve the overall heat dissipation performance and ensure the safe operation of the X-ray source.
²Radiation safety system: Multiple anti radiation leakage design, radiation protection level belongs to similar products.
²Vacuum system: Choose a vacuum system, optimize the testing environment, improve the analysis accuracy of light elements such as magnesium, aluminum, silicon, phosphorus, and sulfur, and greatly expand the analytical capabilities of the R-650 analyzer.
²The temperature monitoring technology of the movement ensures the safe and reliable operation of the radiation source, effectively extending its service life and reducing usage costs.
Hardware advantage
|
detector
|
Original American Amptek silicon drift SDD probe, with a resolution of 129eV ± 5eV, excellent energy linearity and resolution, high peak to back ratio |
X-ray tube |
Maximum power 50W, tube voltage 5-50KV, tube current 0-1000uA; long-life X-ray tube (switchable Rh, Ag, W). |
high voltage power supply |
Maximum power 50 W, voltage 0-50 KV, current 0-1000uA, 8-hour stability ≤ 0.05%. |
signal processor |
Adopting imported signal processor, suitable for high resolution and high counting rate, self-adjusting amplification factor, maximum channel number: 4096. |
Test Process

application field

Energy Dispersive X-ray Fluorescence Spectroscopy RoHS Directive Hazardous Elements