- Phone
-
Address
Room 1106, Zone D, Youkou Industrial Park, No. 377 Chengpu Road, Fengxian District, Shanghai
Shanghai Huaji Electronic Technology Co., Ltd
Room 1106, Zone D, Youkou Industrial Park, No. 377 Chengpu Road, Fengxian District, Shanghai
Interface 1010E is a universal electrochemical workstation that can perform various electrochemical measurements, including electrochemical impedance technology.
Interface 1010E can perform various electrochemical measurements, including electrochemical impedance technology. For example, applications such as physical electrochemistry, electrochemical corrosion, battery testing, fuel cell testing, solar cell testing, and sensor development.
Interface 1010E can be used for single channel, dual channel, or multi-channel combinations. GAMRY provides flexible configuration.
Below are more performance features of Interface 1010E. Each bullet point represents a performance.
Other details
Built in EIS
Through I/O design, control third-party devices: achieve external signal input, analog voltage output, analog current output, auxiliary A/D input, and digital I/O connectors.
2-year manufacturer warranty service.
system |
|
| Potentiostat | correct |
| galvanostat | correct |
| Zero resistance current meter | correct |
| Floating design (insulated from the ground) | correct |
| electrode connection | 2, 3 or 4 electrodes |
| Maximum current | ±1 A |
| Current range | 9 (10 nµA-1A) |
| Current range (including internal gain) | 11 |
| Minimum current resolution | 3.3 fA |
| Maximum applied potential | ±12 V |
| rise time | <1 μs |
| Minimum time base | 10 μs |
| Noise and Ripple (Typical) | <20 μVrms |
| weight | 2.4 kilograms |
| 2.4 kilograms | 24 (W) x 6 (H) x 27 (D) 27 centimeters |
control amplifier |
|
| cell voltage | ±20 V (@ 1A) |
| Output Current | >±1 A |
| speed setting | 5 |
| Gain bandwidth (typical) | 980, 260, 40, 4, 0.4 kHz |
EIS measurement |
|
| Frequency range | 10 μHz - 2 MHz |
| Impedance accurate diagram | Refer to the impedance precise diagram |
| Apply voltage amplitude | 2.33 V maximum 17.8 μV minimum |
Potentiometer |
|
| Input impedance | >1012Ω |
| Input Current | <20 pA |
| bandwidth | >10 MHz |
| CMRR | >80 dB (10 kHz) >60 dB (1 MHz) |
potential |
|
| Apply precision | ± 1 mV ± 0.2% setting range |
| Apply resolution | 200 μV, 50 μV, 12.5 μV/bit |
| measurement accuracy | ± 1 mV ± 0.3% reading range |
| measurement resolution | 1 μV, 10 μV, 100 μV, 400 μV/bit |
Apply current |
|
| Apply precision | ± 5 pA ± 0.3% range |
| Apply resolution | 0.0033% |
measuring current |
|
| measurement accuracy | ± 5 pA ± 0.3% application/measurement resolution |
| measurement resolution | 0.0033% |
| Apply/measure resolution | >10 MHz (1A - 100 μA) >1.5 MHz (10 μA) >0.15 MHz (1 μA) |