Electrical contact bimetal thermometer
ZY electric contact bimetallic thermometer
Application:
Electrical contact bimetal thermometerApplied to the production site for automatic temperature control and alarm. Directly measure the temperature of body, steam, and gas media within the range of -80 to 500 ℃ in various production processes.
characteristic
·On site temperature display, intuitive and convenient;
·Equipped with automatic power-off and alarm functions;
·Safe and reliable, with a long service life;
·Multiple structural forms can meet different requirements.
Working principle
Electrical contact bimetal thermometerIt is to use temperature changes to drive contact changes, and when it is disconnected from the upper and lower limit contacts, the relay in the circuit is activated, thereby automatically controlling and alarming.
Main technical parameters
·Product execution standards: JB/T8803-1998 GB3836-83
·Scale dial nominal diameter: 100
·Accuracy level: (1.0),1.5
·Thermal response time: ≤ 40S
·Protection level: IP55
·Normal working atmospheric conditions: temperature -25~+55 ℃, relative humidity ≤ 85%
·Setpoint error: The set point error should not exceed 1.5 times the basic error limit.
·Switching error: The switching error should not exceed 1.5 times the basic error limit.
·Switching repeatability: The limit range of switching repeatability should not exceed 1/2 of the absolute value of the basic error limit.
| Electrical parameters |
|
Rated power VA
|
Maximum working voltage V
|
Maximum allowable current
|
|
10
|
220 a.c
|
0.7A
|
|
24 d.c
|
|
| Selection code |
|
Model naming method
|
WSS
|
|
Bimetal thermometer
|
|
|
X
|
|
Electrical contact structure
|
|
Nominal diameter of dial
|
-4/5
|
|
Φ100/ф150
|
|
Dial form
|
0
|
|
Axial (straight)
|
|
1
|
|
Radial (angular)
|
|
8
|
|
Wanxiang (adjustable angle type)
|
|
Installation fixed form
|
0
|
|
No fixed device
|
|
1
|
|
Movable external thread
|
|
2
|
|
Movable internal thread
|
|
3
|
|
Fixed thread
|
|
4
|
|
Flange
|
|
5
|
|
Ferrule thread
|
|
6
|
|
Card sleeve flange
|
|
Protection form
|
M
|
|
Upper and lower limits
|
|
N
|
|
Double upper limit
|
|
P
|
|
Double lower limit
|
|
| remarks: |
| Selection notice: Please provide the model, dial diameter, accuracy level, installation and fixing form, temperature measurement range, protective tube material, length or insertion depth. |
| Selection example: Universal type, dial diameter of Φ 100, temperature measurement range of 0-400 ℃, 1.5 levels, movable external thread M27 × 2, length 450mm |
| WSSX-481, 0-400 ℃, L=450, M27 × 2, Class 1.5 |
| Model and specifications |
|
model
|
Measuring range
|
accuracy class
|
Protective tube material
|
specifications
|
Install fixed devices
|
|
WSSX-400/500
|
-80~+40 -40~+80 0~50 0~100 0~150 0~200 0~300 0~400 0~500
|
1.5
|
1Cr18Ni9Ti
304
316 316L Ha Shi C-276
|
75
100
150
200
300
400
500
750
1000
|
No fixed device
|
|
WSSX-401/501
|
|
WSSX-480/580
|
|
WSSX-401/501
|
Movable external thread
|
|
WSSX-411/511
|
|
WSSX-481/581
|
|
WSSX-402/502
|
Movable internal thread
|
|
WSSX-412/512
|
|
WSSX-482/583
|
|
WSSX-403/503
|
Fixed thread
|
|
WSSX-413/513
|
|
WSSX-483/583
|
|
WSSX-404/504
|
Flange
|
|
WSSX-414/514
|
|
WSSX-484/584
|
|
WSSX-405/585
|
Ferrule thread
|
|
WSSX-415/515
|
|
WSSX-485/585
|
|
WSSX-406/506
|
Card sleeve flange
|
|
WSSX-416/516
|
|
WSSX-486/586
|
|
| Note: Special forms can be ordered according to the agreement. |