E-mail
13922803009@126.com
-
Phone
13922803009
-
Address
Shenzhen Shitai Rui'er Industrial Instrument Co., Ltd
Shenzhen Shitai Rui'er Industrial Instrument Co., Ltd
13922803009@126.com
13922803009
Shenzhen Shitai Rui'er Industrial Instrument Co., Ltd
Elastomer sensor ES 5:
Strain gauge sensor with integrated electronics in high-performance elastomer
Compact and very robust strain gauge sensor with fully integrated evaluation unit for outdoor use for measuring cracks, strain, displacement, deflection, esp. building monitoring / crack monitoring.
Elastomer sensor ES 5:
High performance elastomer for +20 years outdoor use
High resolution of up to 5µm possible
High quality temperature compensation
High IP protection, chemical resistant
Supply voltage 12...24 VDC
Output signal 4...20mA or 0...10V / 0...5V
Easy mounting by glueing, screwing, magnets
Important features
Nominal measuring range: 5mm resp. +/-2,5mm
Output signal: 4...20mA or 0...10V / 0...5V
Supply voltage: 12…24 VDC
Cable connection: 3m / 10m / 100m
Protection: IP68 / IP69K
Operating temperature: -40°C. ..+85°C
Temperature compensation: active, parallel strain gauge
Resistant to many chemicals
Suitable for food, medical industry
ES 5 |
||
Nominal measuring range |
5 mm |
|
Linearity |
< 0,5 % |
|
Reproducability |
< 0,1 % |
|
Resolution (standard) |
5 µm |
|
Supply voltage |
12...24 VDC |
|
Power consumption |
< 20 mA |
|
Polarity protection |
no |
|
Sampling Rate intern |
1000 Hz |
|
Dynamic bandwidth |
100 Hz |
|
Recommended dynamic range |
< 10 Hz |
|
Output signal |
Standard: 4 . .. 20 mA |
|
Cable |
Standard: 3 m PE 4-wire, unshielded |
|
Case material |
Silicon Elastomer |
|
Operating temperature |
-40 . .. +85 °C |
|
Drift |
< 0,01 % F.S./K (for Δt ≤ 1 K/Min.) |
|
Protection (DIN 40050) |
IP 68 / IP 69 K |
|
Type of installation |
Bolts, pins or super-magnets |
|
Mounting |
2x eyelet / hole ID Ø6.1mm x 13mm |
|
Nullposition |
Hole spacing / Lm = 60mm |
|
Weight |
about 70 grams |
|
Chemical resistance |
RL |
Water, oil, acid, etc. |
EMC |
According to IEC 60947-5-2 |
|
Mechanical final inspection |
1000 cycles with 150% measuring range |
|
Temperature test |
full cycle -40 to +85 °C |
Further:
Special cable lengths and accessories on request