ESG 3 ESG 7 surge current limiter with current control configuration with no-load detection
ESG 3 / ESG 7
Surge current limiter with current control configuration with no-load detection
Measure voltage 230 Vac ± 10%, maximum measured current 16 A, protection level IP 65 (shell); IP 44 (plug/adapter), power connection cable/socket for protective plug
General data
Measure voltage 230 Vac ± 10%
Measure current up to 16 A
Internal resistance of 7,8 Ohm
Protection level IP 65 (shell); IP 44 (plug/adapter)
The maximum ambient temperature is 40 ° C
advantage
ESG 7: 2 x 1.3-meter power cord with connector and coupling IEC 60321-1 C13/C14
ESG 3: 2 x power connection cables with protective plugs and adapters, compliant with DIN 49440-1 requirements (GER), suitable for mobile applications
High protection level
Both fixed and mobile applications are compatible
Obtaining excellent moisture resistance through XtraDenseFill resin molds
The no-load identification device is energized, which can also implement full current limiting protection during brief reconnection
Dynamic time limit for optimizing the start-up of high starting current loads
application
The current limiting device is used to limit the turn-on current of electric tools, transformers, and other loads with high turn-on current or starting current
| variant |
measuring current |
measure voltage |
Input Interface |
| ESG 3 |
16 A |
230 Vac |
Power connection cable with protective plug DIN 49440-1 (GER) |
| ESG 7 |
10:00 AM |
230 Vac |
Mains cable with low‑heat device plug C14 IEC 60321‑1 |
Product specification sheet download
ESG 3 / ESG 7_datasheet