Welcome Customer !

Membership

Help

Beijing Lanbo High tech Testing Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Beijing Lanbo High tech Testing Instrument Co., Ltd

  • E-mail

    ben.zhang@bj-lab.com

  • Phone

    13581765437

  • Address

    710, Building 3, Aoyu Technology Yingchao, No. 12 Jinxing Road, Daxing District, Beijing

Contact Now

ED1370 non-contact electric thickness gauge

NegotiableUpdate on 11/17
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The ED1370 non-contact electric thickness gauge is used to measure the thickness of steel pipes and flat steel. The operating distance width between the sensor and the measured part can reach 15 mm. The ED1370 can also measure the insulation coating thickness of metal objects (varnish, plastic, anti rust layer, salt layer, etc.). This device uses eddy current measurement method, which calculates the equivalent resistance of the metal using sensors and converts the measured resistance into thickness. This method is insensitive to the surface material of the test piece, so the ED1370 non-contact electric thickness gauge can directly control the thickness of the severely corroded test piece through the insulation layer and anti rust layer without the need for surface treatment in advance

Product Details

ED1370Non contact electric thickness gauge is used to measure the thickness of steel pipes and flat steel. The operating distance width between the sensor and the measured part can reach up to15 mm.ED1370not badMeasure the insulation coating thickness of metal objects (varnish, plastic, rust proof layer, salt layer, etc.). This device uses eddy current measurement method, which calculates the equivalent resistance of the metal using sensors and converts the measured resistance into thickness. This method is not sensitive to the surface material of the test piece, so,ED1370 can directly control the thickness of severely corroded test pieces through insulation and rust prevention layers, without the need for surface treatment in advance

ED1370It can measure the thickness in relative units, or measure the percentage of thickness at any point on the test piece. Therefore, this device can control the test piece made of unknown materials and measure thickness when calibration is not possible.

This device is highly suitable for controlling heating system pipelines, pipelines filled with water, and refined product storage tanks containing water or other substances that promote corrosion.

Technical Specifications

Working temperature range

-20…+50 °C

Thickness range (coating)

0 – 30mm

Thickness range (steel structure)

0 – 10 mm

measurementprecision(Metal)

0.2±0.25*hthickness range0 – 0.99 mm;
±0.25*hthickness range1 – 3.9 mm;
±0.30*hthickness range4 – 6.9 mm;
±0.35*hthickness range7 – 10 mm

measurementprecision(Coating)

0.1mm+3%h

The operating distance between the sensor and the tested component

Gundam15mm

Number of large measurements per second *

3

Continuous working time for one charge

8hour

size

110 x 210 x 41 mm



ED1370 Non contact electric thickness gauge ED1370 Non contact electric thickness gauge ED1370 Non contact electric thickness gauge ED1370 Non contact electric thickness gauge ED1370 Non contact electric thickness gauge ED1370 Non contact electric thickness gauge