ECL2620A piston line gauge Accuracy: (0.025+3H/10000) Load capacity: 40Kg Measurement diameter: 400mm Measurement height: 600mm

Product Details

Measurement project
Measurement project Piston outer circle: cross-sectional profile, longitudinal profile, coaxiality
Piston pin hole: unilateral pin hole roundness, cylindricity, longitudinal section line measurement
Piston ring angle
Roundness, cylindricity, diameter, taper (vertical, plane), concentricity, coaxiality (multi-element), straightness, perpendicularity (multi-element),
Bounce (axial, radial), full bounce (axial, radial), flatness (multi-element), parallelism (multi-element), notch removal, waviness,
Spectral analysis, wave height analysis, harmonic analysis, wall thickness deviation
Spindle Precision
Radial error of spindle
H=to the height of the workbench
±(0.025+3H/ 10000)μm
Axial error of spindle
X=distance to the center of the spindle
±(0.025+6X/10000)μm
workbenches
Table diameter 220mm
adjustment range Adjust the eccentricity by ± 2mm; Adjust the level ± 1 °
Rotation diameter 400mm
Capacity 40Kg
rotational speed 0-12 revolutions per minute
ZAxis (Column)
Straightness (narrow range) 0.35μm /100mm
Straightness (full range) 0.6μm /400mm
Positioning speed 1mm/s-8mm/s
Grating resolution 1μm
Rotation axis and ZParallelism of axis guide rail
Rotation axis and
Z-axis guide rail parallelism
2 μ m/400mm (busbar reference)
Horizontal arm (horizontal guide rail)
Mobile accuracy 1.5μm/150mm
Horizontal movement distance 180mm
Positioning speed 1mm/s-5mm/s
Grating resolution 1μm
sensor
range 500 μ m (radius difference)
resolution 0.005μm
Measuring needle shape 2mm gemstone ball measuring head (with more diameters to choose from)
dynamometry 1-12g
measuring range
Maximum measurement diameter 500mm
Maximum measurement height 400mm
maximum measuring depth Using standard probe: 100mm (when aperture is less than 36mm)
Non standard bracket can measure up to 300mm (aperture greater than 36mm (optional))
data acquisition
data acquisition 7200 points per week (internationally recognized)
Magnification factor
Magnification factor 200000 times automatic
appraising method
appraising method LSC (least squares method), MZC (minimum area method), MIC (maximum inscribed circle method), MCC (minimum circumcircle method)
Filter value
Filter value 1upr,1-15upr,1-50upr,1-150upr,1-500upr
Data analysis and processing
Spectrum analysis Analyze the amplitude of different frequency components
Abnormal data removal Manually or automatically remove abnormal data such as burrs, holes, and bumps
file management Measurement data is automatically saved and can be deleted
Data printing Single or multiple measurement results can be printed on the same page in the same printing mode
INSTALLATION REQUIREMENTS
power supply 220-240V AC, 50HZ, Separate ground wire; Maximum power consumption 450W
compressed air Pure compressed air: pressure 0.4MP, consumption 0.2m3/min (air supply 0.6MP, 0.25m3/min or above)
Environmental requirements Working temperature: 10 ° -30 ° C (normal temperature); Humidity 20-80% RH (no condensation), good grounding, no obvious vibration source