Overview
Dual channel alkalinity analyzer water alkalinity is an important indicator of water quality, which is closely related to industrial water use
Product Details
Dual channel alkalinity analyzer
The alkalinity of water is an important indicator of water quality and has a significant impact on industrial water use.

Alkalinity refers to the absorption in waterprotonThe ability is usually calibrated based on the total amount of substances in water that can react quantitatively with strong acids. The formation of alkalinity in water is mainly due to heavy carbonates, carbonates, andhydroxideThe presence of borates, phosphates, and silicates can also produce some alkalinity. Wastewater and other complex water systems also containorganic-baseClass, metal hydrolysissaltAll of them are components of alkalinity.
In these cases, alkalinity becomes a comprehensive indicator of water, representing its ability to withstand strong acids滴定The total sum of matter.
To provide a basis for determining water quality and conducting water treatment.To meet the needs of on-site online analysis, traditional and mature national standard testing methods are adopted, which have the advantages of miniaturization, integration, and automation.
Measurement method: Potentiometric titration method
Compliant with standards:

Industrial Boiler Water Quality StandardsGB/T 1576-2018

How to translateGB/T 50050 Industrial Circulating Cooling Water Quality Standard
—2007How to translate
Application field: Ultra pure water/Steam and condensate water/Ion exchange system/Boiler feedwater/surface water analysis/analysis of drinking water/monitoring of industrial water

Selectable display units for switching:mmol/l Mmol/l mg/lMeasurement principle: Principle: Determine the alkalinity of water samplesUsing a glass electrode as the indicator electrode and a calomel electrode as the reference electrode, titrate the endpoint with an acid standard solutionpH Meter or potentiometric titrator indicationwithpH 8.3 Indicate the endpoint at which hydroxides in water samples are neutralized and carbonates are converted to bicarbonateWhen the phenolphthalein indicator has just fadedpHEquivalent valuewithpH 4.4~4.5Representing heavy carbonates in water (Including original heavy carbonates and heavy carbonates converted from carbonates) The endpoint of neutralizationThe methyl orange has just turned orange redpH
Value equivalent to industrial wastewater or water containing complex componentscanpH 3.7
Titration endpoint indicating total acidity Potentiometric titration can be plotted as droplet timingpHCalculate the content of the corresponding component or directly titrate to the specified endpoint based on the titration curve of the acid standard titrant dosage Step: Titrate with hydrochloric acid standard solution, When titrated to pH 8.3
timeArrive at the destinationThe endpoint indicated by phenolphthaleinRecord the consumption of hydrochloric acid standard solutionContinue titrating with hydrochloric acid standard solution until pH Value reaching
4.4~4.5timeArriving at the second endpointThe endpoint indicated by methyl orange records the amount of hydrochloric acid standard solution used.Optional component: equipped with a low liquid level alarm indicator for pharmaceuticals; Remote data transmission system; auto-calibration
/
verify
/

Features and advantages

National standard method, accurate measurement, good repeatability, stable and reliable; Equipped with automatic cleaning function; Precision pumps are maintenance free;Equipped with advanced modular configuration, it has a small size and is easy to install. Connect the medication, sampling interface, and wastewater pipeline to operate;Has an alarm indication for missing sample input; Long term automatic operation, low maintenance, and low operating costs;
A sturdy and sturdy casing designed specifically for industrial environments, ensuring optimal online operation and fully protecting electrical, mechanical, and liquid pipeline components;Analysis time:3min
; Medications used: Two types of medications
Sampling frequency (cycle time):
15-120min, adjustable settings;Technical Indicators:Range:The
20-45mmol/l0-4500mg/lThe
0-9mmol/l0-900mg/l
Power Supply: ­220VAC
12VDCInstallation method: wall installation or workbench supportOperating Temperature
5-45°CProtection level:IP55Cold rolled steel plate, epoxy powder coatingSize:3600Lx500Hx250Pmm
weight: aboutkilogram模拟输出:一路4 – 20mA
Digital output:1RS485
MODBUS RTU
Alarm relay:Road relay (over limit alarm)Sample temperature:
5°-45°C
Imported sample pressure:2kg