Welcome Customer !

Membership

Help

Mingyu Instrument (Huai'an) Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Mingyu Instrument (Huai'an) Co., Ltd

  • E-mail

  • Phone

  • Address

    No. 88 Huancheng West Road, Jinhu County, Huai'an City, Jiangsu Province

Contact Now

Dry well temperature calibrator MY-S100 temperature detection

NegotiableUpdate on 05/25
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

MY-S100 Dry Well Temperature Calibration Instrument Dry body furnace, also known as dry well, dry well furnace, dry metering furnace, temperature metering furnace, temperature calibrator, dry body temperature calibration furnace. Dry body furnace is a traditional on-site heat source (temperature field) that is convenient to carry and has a fast temperature rise and fall speed. The dry body furnace adopts a high stability temperature controller, and the homogenization block is made of alloy material with good thermal conductivity.

Product Details

Dry well temperature calibrator detailed

干井式温度校验仪MY-S100温度检测


MY-S100 Dry Well Temperature Calibration InstrumentDry furnace, also known as dry well, dry well furnace, dry measuring furnace, temperature measuring furnace, temperature calibrator, dry type temperature calibration furnace. Dry body furnace is a traditional on-site heat source (temperature field) that is convenient to carry and has a fast temperature rise and fall speed. The dry body furnace adopts a high stability temperature controller, and the homogenization block is made of alloy material with good thermal conductivity. Technologically, it belongs to the high temperature industry and is at the same level of high-tech technology synchronization. In terms of insertion depth, horizontal temperature field, vertical temperature field and other technical aspects, it is in a leading positionhigh technologyLevel. Used within the required temperature range, it is widely used in industries that require on-site temperature calibration, such as pharmaceuticals (GMP wet heat sterilization, dry heat sterilization), machinery, ships, chemicals, biological products, power plant substations, steel plants, metrology testing, scientific research, etc. A dry furnace can provide a stable, uniform, and accurate temperature environment (temperature field), similar to a constant temperature bath (liquid bath), but it is easy to carry and does not require the placement of liquids. The time for the dry furnace to reach the predetermined temperature point and stabilize the temperature is 5 to 10 times faster than that of a constant temperature bath, which can greatly save the time of calibration personnel and improve the speed of temperature calibration. The portability of the dry furnace enables on-site calibration work, thereby solving the difficulty of transporting and moving the constant temperature bath. Temperature sensors such as mercury thermometers, expansion thermometers, thermocouples, thermistors, etc. can be easily calibrated through a dry body furnace.

The dry well temperature calibrator has the following product features:

*More portable and lightweight. Higher accuracy.

*Human computer interface, Chinese display, touch operation, beautiful and elegant.

*One click temperature setting, easy to operate. Quickly heat up and control the temperature.

*According to customer requirements, language interfaces from anywhere in the world can be copiedExit easily.

Technical guidance for dry well temperature calibrator:


typenumber

MY-S100

WenRange of degrees(When the room temperature is ≤ 22 ℃)

-100℃ -40℃

display resolution

0.01℃

Control method

touch screen

accuracy

±0.3℃

Radial uniformity

±0.2℃

Verify hole depth

145mm

Default display

Chinese display full color LCD or

Diameter of uniform heating block

30mm

Verify hole diameter

4mm、6mm、8mm、 10mm(Customizable)

Number of verification holes

4 (customizable)

size(Long)X wide X tall)

320mmX 195mm X530mm

weight

15.2KG

power supply

220V AC 50HZ

adjustment method

Automatic power adjustment

language

According to customer requirementsCan copy languages from anywhere in the world

working conditions

20℃—25℃ 80%RH

Precautions for using dry well temperature calibrator:

*Before the machine, firstCheck for any abnormalities in the equipment(such as bumps and other phenomena). If there is any abnormal noise when starting up, immediately turn off the power and contact the manufacturer,If not available, it can be turned on and run.

*When used on site, the power plug should be reliably groundedInsert the device plug into the bottom of the device to avoid poor contactThe current equipment is on fireElephant.

*To ensure temperature measurement accuracy and ideal usage environmentThe temperature should≤25℃

*The testing work must start from the low temperature point firstGo to the high temperature point again to avoid the rapid temperature changes affecting the furnaceDamage caused by electronic components; When the device stops using, the first thing to do is to prohibit itDirectly set low temperature from high temperature for cooling, and secondlyIt is prohibited to directly operate the equipment above 100 ℃Shut down to avoid damage to the device!

*The standard aperture on the temperature equalization block is 4mm/6mm/6mm/8mm/10mmPut the tested sensor into the inspection When drilling, the diameter of the detection hole should be larger than the diameter of the sensor being testedThe diameter shall not exceed 0.5mm.

*For example, if the diameter of the tested sensor is 5.5mm, a 6mm aperture should be placed instead of 8mm or 10mm The aperture size, otherwise it will affect the test results. If the standard size cannot meet the inspection requirements, it should be promptly reported to our companyContact, SpecialCustomized verification aperture.

*The calibration hole depth on the temperature equalization block is standard at 165mm, and the armored part of the tested sensor should be ≥ 165mm before being placed for calibration The bottom of the hole should be in contact with the bottom surface to avoid affecting the test results.If the length of the armored part of the tested sensor is ≤165mmIt should beContact our company promptly and inform them of the testing method or special customized dry body furnace.

*During transportation, the heat equalizing block should be individually packaged and strictly prohibited from being placedTransport inside the device together with the equipment to avoid transportation during the processThe heavy impact of the temperature equalization block caused damage to the equipment; Average temperature during useBlock application temperature equalization block handle tightened slowly and placed into the deviceIn the middle.

*Before installing or moving the instrument, please turn off the power to avoid accidents such as electric shock.

*If the equipment is not used for a long time, be sure to put it awayKeep in a cool and ventilated environment to avoid damage to equipment components caused by humid conditions.

Common knowledge of dry furnace:

1. The dry body furnace is a constant temperature device and cannot be used as a standard. It needs to be equipped with a standard and reading instrument. If the tested sensor requires low accuracy, the dry body furnace can also be regarded as a standard heat source. Please refer to the factory test report for specific data.

2. The accuracy of the dry furnace is obtained through calibration testing with second-class standard sensors before leaving the factory. The calibration results cannot be used as legal basis, and the final test results shall be subject to calibration by a third-party metrology institution. However, the second-class standard sensors and digital meters used by our company meet national requirements.